Rodrigo Rabello

Dr. Rodrigo Rabello

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 January 2022 in Journal of Bodywork and Movement Therapies
Verified
Journal Article
Closed access
IPIsabel de Almeida Paz
Isabel de Almeida Paz
MFMichele Fernandes Frigotto
Michele Fernandes Frigotto
CCCharles Alexandre Cardoso
Charles Alexandre Cardoso
RRRodrigo Rabello
Rodrigo Rabello
RRRodrigo Rodrigues
Rodrigo Rodrigues

6 June 2019 in Ultrasound
Verified
Journal Article
Closed access
PDF file
RRRodrigo Rabello
Rodrigo Rabello
MFMatias Fröhlich
Matias Fröhlich
ABAline Felicio Bueno
Aline Felicio Bueno
MMMiriam Allein Zago Marcolino
Miriam Allein Zago Marcolino
TBThainá De Bona Bernardi
Thainá De Bona Bernardi
MVMarco Aurélio Vaz
Marco Aurélio Vaz
Introduction: The ultrasound technique has been extensively used to measure echo intensity, with the goal of measuring muscle quality, muscle damage, or to detect neuromuscular disorders. However, it is not clear how reliable the technique is when comparing different days, raters, and analysts, or if the reliability is affected by the muscle site where the image is obtained from. The goal of this study was to compare the intra-rater, inter-rater, and inter-analyst reliability of ultrasound measurements obtained from two different sites at the rectus femoris muscle. Methods: Muscle echo intensity was quantified from ultrasound images acquired at 50% [RF50] and at 70% [RF70] of the thigh length in 32 healthy subjects. Results: Echo intensity values were higher ( p = 0.0001) at RF50 (61.08 ± 12.04) compared to RF70 (57.32 ± 12.58). Reliability was high in both RF50 and RF70 for all comparisons: intra-rater (ICC = 0.89 and 0.94), inter-rater (ICC = 0.89 and 0.89), and inter-analyst (ICC = 0.98 and 0.99), respectively. However, there were differences ( p < 0.05) between raters and analysts when obtaining/analyzing echo intensity values in both rectus femoris sites. Conclusions: The differences in echo intensity values between positions suggest that rectus femoris's structure is not homogeneous, and therefore measurements from different muscle regions should not be used interchangeably. Both sites showed a high reliability, meaning that the measure is accurate if performed by the same experienced rater in different days, if performed by different experienced raters in the same day, and if analyzed by different well-trained analysts, regardless of the evaluated muscle site.

14 October 2023 in Journal of Electromyography and Kinesiology
Verified
Journal Article
Open access
RRRodrigo Rabello
Rodrigo Rabello
CBClaudia Brunetti
Claudia Brunetti
Filippo BertozziFilippo Bertozzi
Filippo Bertozzi
RRRodrigo Rodrigues
Rodrigo Rodrigues
Chiarella SforzaChiarella Sforza
Chiarella Sforza
Knee abduction and hip adduction during functional tasks may indicate increased joint injury risk and discriminate between pathological and healthy people. Muscles' neuromuscular variables such as amplitude (EMGAMP) and onset (EMGONSET) have been used to explain kinematics. The study aimed to evaluate the correlation between two EMG variables of seven trunk and lower limb muscles and 3D kinematics during two tasks. Eighteen physically-active women participated in the study. The following variables were obtained during single-leg squat and anterior step-down: (i) EMGAMP and EMGONSET of fibularis longus (FL), tibialis anterior (TA), vastus medialis (VM), biceps femoris (BF), gluteus medius (GMED), ipsilateral (OB_IL) and contralateral (OB_CL) external obliques and (ii) knee abduction and hip adduction angular displacement (initial angle - angle at 60° of knee flexion). Spearman's correlation coefficient was calculated between kinematic and EMG variables. Greater knee abduction was correlated with delayed TAONSET, GMEDONSET and OB_ILONSET during step-down. Greater hip adduction was correlated with lower VMAMP, BFAMP and delayed VMONSET during step-down. Although task-specific, these results suggest that EMGONSET may influence knee abduction, while both EMGONSET and EMGAMP may affect hip adduction. The identification of muscle activation patterns in relation to kinematics may help the development of injury prevention and rehabilitation programs.

9 May 2024 in Biomechanics
Verified
Journal Article
Open access
PDF file
PGPablo Gaviraghi
Pablo Gaviraghi
FSFrancesca Chaida Sonda
Francesca Chaida Sonda
MFMichele Fernandes Frigotto
Michele Fernandes Frigotto
TMTalita Molinari
Talita Molinari
LCLuiza Pizarro Chaffe
Luiza Pizarro Chaffe
RRRodrigo Rodrigues
Rodrigo Rodrigues
Background: Despite the potential connection between hip and knee muscle control, there is limited research on the effects of hip abductor fatigue on the hip and knee neuromuscular responses in both males and females. This study aimed to investigate the influence of sex on the hip and knee frontal plane kinematics and the EMG responses of the hip abductors and knee extensor muscles during the single-leg squat before and after hip abductor fatigue. Methods: A total of 30 participants (males, n = 15; females, n = 15) performed single-leg squats before and immediately after a hip abductor fatigue protocol (10° hip abduction position while bearing a 20% load of their estimated 1RM until exhaustion). The frontal plane kinematics (hip adduction and knee frontal plane projection angle) and EMG parameters (amplitude and median frequency) of the gluteus medius (GMed), tensor fascia latae (TFL), vastus lateralis (VL) and vastus medialis (VM) were measured during the single-leg squat. Results: We did not find any effects of hip abductor fatigue or interaction between fatigue and sex on the evaluated parameters (p > 0.05). However, compared to males, females had greater values for the hip and knee frontal plane kinematics (p = 0.030), GMed EMG amplitude (+10.2%, p = 0.012) and median frequency (+10.3%; p = 0.042) and lower VL median frequency (−9.80%; p = 0.007). Conclusions: These findings establish sex-related differences in the kinematics and hip and knee EMG parameters during the single-leg squat, which were not influenced by the hip abductor fatigue protocol.

15 June 2020 in Gait & Posture
Verified
Journal Article
Closed access
LFLuan Fitarelli
Luan Fitarelli
GRGiovana Ramos
Giovana Ramos
FSFelipe Scudiero
Felipe Scudiero
RRRodrigo Rabello
Rodrigo Rabello
RRRodrigo Rodrigues
Rodrigo Rodrigues

15 October 2021 in Sport Sciences for Health
Verified
Journal Article
Open access
PDF file
RRRodrigo Rabello
Rodrigo Rabello
CNCamila Nodari
Camila Nodari
FSFelipe Scudiero
Felipe Scudiero
IBIury Borges
Iury Borges
LFLuan Fitarelli
Luan Fitarelli
RRRodrigo Rodrigues
Rodrigo Rodrigues
Purpose: Fatigue-induced hip-abductor weakness may exacerbate lower-limb misalignments during different dynamic single-leg tasks. We sought to evaluate the effects of fatigue and task on lower limb kinematics and muscle activation and to find associations between measurements obtained in two tasks. Methods: One-group pretest–posttest design. Seventeen healthy adults (9 W) performed the single-leg squat (SLSQUAT) and the single-leg hop (SLHOP) before and after a hip-abduction fatigue protocol. Hip adduction, knee frontal plane projection angle (knee FPPA) and heel inversion displacement were measured during the eccentric phase of the SLSQUAT and the SLHOP, as well as activation of the gluteus medius (GMed), tensor fascia latae (TFL), peroneus longus (PER) and tibialis anterior (TA). Moments and tasks were compared using a repeated-measures two-way ANOVA. Correlation between tasks was evaluated using Spearman’s correlation. Results: No differences in kinematics or activation were found between moments. Hip-adduction displacement (P = 0.005), GMed (P = 0.008) and PER (P = 0.037) activation were higher during SLSQUAT, while TA activation was higher during SLHOP (P < 0.001). No differences were found between tasks in knee FPPA and heel inversion. Hip-adduction and knee FPPA were not correlated between tasks, while ankle inversion displacement was positively correlated (rs = 0.524–0.746). Conclusion: Different characteristics of SLSQUAT (slower and deeper) seem to have led to increased hip adduction displacement, GMed, and PER activation and decreased TA activation, likely due to higher balance requirements. However, hip-abductor fatigue didn’t influence lower-limb alignment during the tasks. Finally, evaluations should be performed with different single-leg tasks since they don’t give the same lower-limb alignment information.