Nowadays, many countries include requirements for building airtightness in their current national regulations or energy-efficiency programs, mainly for concern about reducing building energy consumption due to air leakage. Moreover, more and more countries impose a mandatory justification with an air leakage measurement at building commissioning. Therefore, the uncertainty of the measurements results has become a key concern in several countries over the past year. More specifically, the influence of wind speed has been identified as one of the major sources of error on the measurement result. The goal of this paper is to present the experimental facility we design and built to improve the uncertainty estimates and the measurement protocol based on model scale experiments in controlled laboratory conditions. We first present the similarity criteria we identified for our model scale experiment. Secondly, we present the experimental design. Finally, we characterize the wind speed inside the wind tunnel and we present the preliminary results regarding the reproduction of fan pressurization tests on the model for different leakage distributions.
In many countries, building airtightness is mandated by national regulations or energy efficiency programs, necessitating accurate measurements using the fan pressurization method. Given the significant influence of wind on measurement uncertainty and the need for reliable regulatory tests, experimental studies in a controlled environment are needed. This paper presents a novel experimental facility designed to replicate fan pressurization measurements on a model scale under controlled laboratory conditions. The key features of the facility include the ability to (1) conduct fan pressurization measurements, (2) generate steady wind conditions across varying wind speeds, and (3) accurately measure parameters like the pressure difference, wind speed, and airflow rate. The experimental facility includes a pressurization device, a wind tunnel, and a model representing a two-story house with nine distinct leakage distributions. A total of 96 fan pressurization measurements were executed using this setup, adhering to the similarity conditions specifically defined for assessing airflow errors due to wind. These tests followed the ISO 9972 standard, with the pressure differences ranging from 10 Pa to 100 Pa and steady wind speeds from 1 m·s−1 to 7.5 m·s−1. This experimental facility marks a significant advancement in understanding the effect of wind on building airtightness measurements.
Impact du vent pendant une mesure d'étanchéité à l'air de l'enveloppe des bâtiments: Afin de réduire la consommation d’énergie due aux défauts d’étanchéité de l’enveloppe des bâtiments, de nombreux pays incluent désormais des exigences concernant l’étanchéité à l’air dans leur réglementation nationale ou leurs certifications de bâtiments performants. Parmi ces exigences, certaines incluent notamment une justification obligatoire du niveau d’étanchéité à l’air à travers la réalisation d’une mesure de perméabilité à l’air in-situ. Dans ce contexte, assurer la fiabilité du résultat de ses mesures est devenu essentiel et fait l’objet de travaux de recherche par la communauté scientifique internationale. Plus particulièrement, les chercheurs s’intéressent à l’impact du vent pendant ses mesures, qui a été identifié comme l’une des sources majeurs d’erreurs pendant ces mesures, et reste aujourd’hui un sujet qui nécessite encore des travaux de recherche. L’objectif des travaux de thèse présenté dans ce manuscrit est d’améliorer l’évaluation de l’incertitude de mesure et les protocoles de mesure à partir de tests réalisés à échelle réduite dans des conditions de laboratoire contrôlées. Dans un premier temps, ce manuscrit de thèse propose une analyse de la littérature concernant les sources d’incertitudes lors d’une mesure d’étanchéité à l’air par pressurisation du bâtiment. La seconde partie décrit la méthodologie de conception d’un banc expérimental à échelle réduite qui comprend une soufflerie, un modèle une-zone de bâtiment et un appareil de mesure par pressurisation. La partie 3 du manuscrit présente les résultats de la validation du banc expérimental vis à vis des champs de pression et de vitesse de vent dans la soufflerie, ainsi que la reproduction à échelle réduite d’un test par pressurisation dans différentes conditions de vent et pour différentes répartitions des fuites sur l’enveloppe du modèle. La partie 4 propose une évaluation de l’incertitude du résultat de la mesure dans des conditions de vents constants.