Wanli Huo

Dr. Wanli Huo


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 January 2024 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
CSCong Sheng
Cong Sheng
YDYu Ding
Yu Ding
YQYaping Qi
Yaping Qi
MHMan Hu
Man Hu
JZJianguang Zhang
Jianguang Zhang
WHWanli Huo
Wanli Huo
Objective. Proton radiograph has been broadly applied in proton radiotherapy which is affected by scattered protons which result in the lower spatial resolution of proton radiographs than that of x-ray images. Traditional image denoising method may lead to the change of water equivalent path length (WEPL) resulting in the lower WEPL measurement accuracy. In this study, we proposed a new denoising method of proton radiographs based on energy resolved dose function curves. Approach. Firstly, the corresponding relationship between the distortion of WEPL characteristic curve, and energy and proportion of scattered protons was established. Then, to improve the accuracy of proton radiographs, deep learning technique was used to remove scattered protons and correct deviated WEPL values. Experiments on a calibration phantom to prove the effectiveness and feasibility of this method were performed. In addition, an anthropomorphic head phantom was selected to demonstrate the clinical relevance of this technology and the denoising effect was analyzed. Main results. The curves of WEPL profiles of proton radiographs became smoother and deviated WEPL values were corrected. For the calibration phantom proton radiograph, the average absolute error of WEPL values decreased from 2.23 to 1.72, the mean percentage difference of all materials of relative stopping power decreased from 1.24 to 0.39, and the average relative WEPL corrected due to the denoising process was 1.06%. In addition, WEPL values correcting were also observed on the proton radiograph for anthropomorphic head phantom due to this denoising process. Significance. The experiments showed that this new method was effective for proton radiograph denoising and had greater advantages than end-to-end image denoising methods, laying the foundation for the implementation of precise proton radiotherapy.

21 August 2024
Verified
Book Chapter
Closed access
PDF file
YTYing Tang
Ying Tang
ZCZhongyue Chen
Zhongyue Chen
YDYu Ding
Yu Ding
LMLingli Mao
Lingli Mao
ZPZhao Peng
Zhao Peng
SWSenting Wang
Senting Wang

31 July 2024
Verified
Book Chapter
Closed access
PDF file
YTYing Tang
Ying Tang
ZCZhongyue Chen
Zhongyue Chen
MYMinchao Ye
Minchao Ye
ZZZhaojuan Zhang
Zhaojuan Zhang
YQYaping Qi
Yaping Qi
WHWanli Huo
Wanli Huo

30 July 2024
Verified
Book Chapter
Closed access
PDF file
YTYing Tang
Ying Tang
ZCZhongyue Chen
Zhongyue Chen
MYMinchao Ye
Minchao Ye
ZZZhaojuan Zhang
Zhaojuan Zhang
YQYaping Qi
Yaping Qi
WHWanli Huo
Wanli Huo