Aguinaldo Fraddosio

Dr. Aguinaldo Fraddosio

Department of Civil Engineering Sciences and Architecture, Polytechnic University of Bari, Bari, Italy
orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2014 in Composites Part B: Engineering
Verified
Journal Article
Closed access
ACAnna Castellano
Anna Castellano
PFPilade Foti
Pilade Foti
Aguinaldo FraddosioAguinaldo Fraddosio
Aguinaldo Fraddosio
SMSalvatore Marzano
Salvatore Marzano
MPMario Daniele Piccioni
Mario Daniele Piccioni

1 October 2018 in Composites Part B: Engineering
Verified
Journal Article
Closed access
ACAnna Castellano
Anna Castellano
Aguinaldo FraddosioAguinaldo Fraddosio
Aguinaldo Fraddosio
MPMario Daniele Piccioni
Mario Daniele Piccioni

1 February 2019 in Composite Structures
Verified
Journal Article
Closed access
Aguinaldo FraddosioAguinaldo Fraddosio
Aguinaldo Fraddosio
GPGaetano Pavone
Gaetano Pavone
MPMario Daniele Piccioni
Mario Daniele Piccioni

24 March 2021 in Journal of Nondestructive Evaluation, Diagnostics and Prognostics of Engineering Systems
Verified
Journal Article
Closed access
PDF file
ACAnna Castellano
Anna Castellano
Aguinaldo FraddosioAguinaldo Fraddosio
Aguinaldo Fraddosio
MPMario Daniele Piccioni
Mario Daniele Piccioni
TKTribikram Kundu
Tribikram Kundu
When stress in concrete exceeds certain threshold value, microcracks are nucleated, these microcracks can propagate and coalesce forming macrocracks, resulting in the gradual decay of the mechanical properties of concrete and eventual failure of the concrete structures. For safety concerns, one needs to develop suitable nondestructive testing methods capable of detecting past overloads of concrete structures during its service life. In this work, the stress-induced damage in concrete is monitored using ultrasonic techniques, exploiting the coupling between the stress level experienced by concrete and its wave propagation parameters. Cyclic compression tests with increasing maximum load level have been performed on specimens made of concrete with coarse-grained (CG) aggregates. Experimental results have been analyzed by two different ultrasonic methods—the linear and the nonlinear ultrasonic techniques. In linear ultrasonic technique, the stress level experienced by the specimens is related to the variations in signal amplitude and velocity of ultrasonic waves. In nonlinear ultrasonic method, the sideband peak count (SPC) technique is used for revealing the stress-induced damage corresponding to each load step. In comparison to linear ultrasonic parameters, the nonlinear ultrasonic parameter SPC-I appears to be more sensitive to the variations of the internal material structures during both loading and unloading phases. Moreover, the SPC technique has shown to be capable of identifying both the initial damage due to the evolution and nucleation of microcracks at the microscopic scale, and the subsequent damages induced by high overload, resulting in an irreversible degradation of the mechanical properties.

1 May 2017 in Composites Part B: Engineering
Verified
Journal Article
Closed access
ACAnna Castellano
Anna Castellano
Aguinaldo FraddosioAguinaldo Fraddosio
Aguinaldo Fraddosio
MPMario Daniele Piccioni
Mario Daniele Piccioni

1 January 2017 in Procedia Engineering
Verified
Journal Article
Open access
ACAnna Castellano
Anna Castellano
Aguinaldo FraddosioAguinaldo Fraddosio
Aguinaldo Fraddosio
SMSalvatore Marzano
Salvatore Marzano
MPMario Daniele Piccioni
Mario Daniele Piccioni