Continuous glucose monitoring using subcutaneous sensors is useful in the management of glucose control in neonatal intensive care. We evaluated feasibility and reliability of a continuous glucose monitoring system in a population of very low birth weight neonates needing parenteral nutrition. Moreover, we presented percentiles of glycemia of the studied population. Very low birth weight neonates were enrolled within 24 h from birth. An ENLITE sensor connected to a continuous glucose monitoring system was inserted and maintained for at least 72 h. Data obtained with the continuous glucose monitoring system and with a glucometer were compared. Calibration was performed every 12 h. Twenty-three patients (9 males) were included. Median gestational age was 28 weeks (range 23–30) and median birth weight was 860 g (range 500–1092). A total of 299 paired glucose values were obtained. Modified Clarke Error Grid criteria for clinical significance were met. 74 and 33 episodes of hypoglycemia and hyperglycemia were detected, respectively. 31,329 values of glycemia were analyzed and the percentiles calculated. This continuous glucose monitoring system is safe and accurate. It allows increasing the detection of hypo- and hyper-glycaemia episodes and it could be routinely used in the management of glucose infusion in very low birth weight neonates under total parenteral nutrition.
Ability to maintain a normal body temperature in an open crib is an important physiologic competency generally requested to discharge preterm infants from the hospital. The aim of this study is to assess the feasibility of an early weaning protocol from incubator in preterm newborns in a Neonatal Intensive Care Unit. 101 infants with birth weight < 1600 g were included in this feasibility study. We compared 80 newborns successfully transferred from an incubator to open crib at 1600 g with 21 infants transferred at weight ≥ 1700 g. The primary outcome was to evaluate feasibility of the protocol and the reasons for the eventual delay. Secondary outcomes were the identification of factors that would increase the likelihood of early weaning, the impact of an earlier weaning on discharge timing, and the incidence of adverse outcomes. Newborns in the study period were then compared with an historical control group with similar characteristics. Early weaning was achieved in 79.2% of infants without significant adverse effects on temperature stability or weight gain. Delayed weaning was mainly due to the need of respiratory support. Gestational age affected the likelihood of early weaning (OR 1.7282 95% CI: 1.3071 - 2.2850). In the multivariate linear regression, early weaning reduced length of stay (LOS) by 25.8 days (p < 0.0001). Preterm infants can be weaned successfully from an incubator to an open crib at weight as low as 1600 grams without significant adverse effect. Early weaning significantly reduces LOS in preterm newborns.
A physiologic test for estimating BPD rate has been developed by Walsh and collaborators. Actually there are not standard criteria for weaning from CPAP and/or oxygen therapy the premature babies. Aim of this study was to verify if a physiologic test, modified respect to that developed by Walsh and collaborators for estimating BPD rate, can be used as a clinical tool for weaning the premature babies from CPAP and/or oxygen therapy. Neonates with BW 500–1250 g and GA ≤ 32 weeks, receiving FiO2 ≤ 0.30 by hood or CPAP, were prospectively studied at 28 days of life and at 36 weeks of postmestrual age. The test was performed in 3 steps: baseline, challenge (FiO2 and CPAP reduction to room air) and post test (room air). Monitoring of transcutaneous CO2 was added to SpO2 and the newborns passing the test were left in room air. Six of 23 tested babies (26%) passed the challenge at 28 days of life, 4 of 10 tested babies (40%) passed the challenge at 36 weeks. Median values of SpO2 were significantly higher in the neonates passing the test, respect to the failing patients. At the same time median values of TcPCO2 were significantly higher in the latter babies. TcPCO2 monitoring appeared to be a new useful parameter for failure prediction of weaning. The test represented a clinical guide because the newborns passing it were left in room air.
Pyloric atresia (PA) is a very rare condition. Its incidence is approximately 1 in 100,000 newborns and constitutes about 1% of all intestinal atresias. We describe the neonatal course of a peculiar case of type 1 pyloric atresia, in which the pyloric membrane was connected to a second duodenal membrane through a virtual duodenal lumen in a premature newborn. The atypical variant required an unusual side to side gastroduodenostomy. We emphasize the importance of a prompt diagnosis to avoid potentially fatal complications and to warrant a good outcome even in the presence of a strange form of PA in the neonatal period.
Fibreoptic Phototherapy (FPT) allows to lower total serum bilirubin (TSB) levels in healthy neonates maintained in rooming-in with their mothers. The 2004 Cochrane review showed that, differently from preterm neonates, FPT was not as effective as traditional phototherapy in term neonates (TN), unless the simultaneous utilization of two FPT devices. Aim of this study was to compare the efficacy of two FPT devices, both equipped with a single light-emitting diode (LED): the first one has a single large pad wrapped around the infant body (Bilisoft, GE Health Care) (device A), the second one is a double-pad phototherapy device (BiliCocoon, CremascolieIris) (device B). We studied 172 healthy neonates with non-hemolytic hyperbilirubinaemia: 57 TN and 57 late preterm neonates (LPN) treated with device A (Group 1); 47 TN and 11 LPN treated with device B (Group 2). We evaluated the differences between groups by the Student’s t-test for continuous variables and by chi square test for categorical data. A two tailed p < 0.05 was considered significant. There were no differences in term of duration of FPT, TSB hourly reduction, percentage of TSB reduction after FPT, TSB maximum rebound, percentage of TSB increase after FPT discontinuation and number of after-discharge checks. Two neonates treated with device B showed no decrease in TSB values during FPT. Seven infants treated with device B experienced hyperpyrexia. The two LED FPT devices were both effective in lowering TSB either in TN or LPN. Device A was effective in all treated neonates without negative side effects during treatment; device B was effective in all but 2 infants and 12% of the neonates in the same group experienced hyperpyrexia. According to our results, the single big pad wrapped around the infant body has the same efficacy as a double FPT device in TN and LPN.