Improving the energy efficiency of buildings is an important element of the effort to address global warming. The thermal performance of building envelopes is the most important thermal and physical property affecting energy performance. Therefore, identifying the thermal performance of a building envelope is essential to applying effective energy-saving measures. The U-value is a quantitative indicator of the thermal performance of the building envelope quantitatively. Methods for determining the U-value are largely classified into passive methods, which use building information without measurement campaigns, and active methods, which conduct in situ measurements. This paper reviews and evaluates the most commonly used methods and experimental results of previous studies to determine the actual U-value of a building envelope. Accordingly, this paper focuses solely on field measurement studies, excluding laboratory measurements. Comparing the existing methods used to determine the U-value can help researchers choose appropriate field measurement methods and future research directions.
29 December 2023 in Sustainable Cities and Society
Among the envelope components (e.g., walls, roofs, floors, and windows, etc.) affecting the cooling and heating load of buildings, windows are the most thermally vulnerable. Shading devices can minimize the thermal load on windows due to solar radiation and decrease radiation effects. However, the load changes due to convection and conduction should be considered. Therefore, when a shading device is applied to a window, control logic for thermal blocking and heat retention is necessary to prevent the load changes. In addition, by combining the opposite features of photovoltaic (PV) that require solar radiation and the shading device to block solar radiation, energy-saving and production can be achieved simultaneously. Therefore, this study minimized the thermal effects of windows using a movable shading device integrated with PV and evaluated the PV power generation. This study evaluated the effects on window heat transfer by applying artificial intelligence techniques, which have recently attracted attention, to system operation. To achieve this, artificial neural network (ANN)-based control logic was developed, and the control performance of the system was assessed using simulations. In ANN control, the window heat transfer was 86.3% lower in a cooling period and 9.7% lower in a heating period compared with that of a shading device fixed at 45°. Furthermore, the PV system produced 3.0 to 3.1% more electric power under optimal control during the cooling period.