Cultured meat presents a possible alternative to conventional meat products and may be used to address growing food demands attributable to global population growth. Thus, a comprehensive technological prospection of the scientific literature related to cultured meat produced by 3D bioprinting is of great interest to researchers. The purpose of this article is to review and analyze published studies related to the biofabrication of cultured meat using 3D bioprinting techniques. The growing number of related publications in recent years highlights that cultured meat has gained traction in the scientific community. Furthermore, private companies and startups have contributed to advancements in the biofabrication of cultured meat for consumption, illustrating that cultured meat as a conventional meat substitute is already becoming reality. However, like any scientific advance, 3D bioprinting of cultured meat faces challenges involving regulation, acceptance, the selection of ideal biomaterials and cell lines, the replacement of fetal bovine serum (FBS), and attaining a texture and nutritional value similar to those of conventional meat.
This work proposes the synthesis of a new polymer with imprinted ions (IIP) for the pre-concentration of uranium in natural waters using digital imaging as a detection technique. The polymer was synthesized using 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol (Br-PADAP) for complex formation, ethylene glycol dimethacrylate (EGDMA) as a crosslinking reagent, methacrylic acid (AMA) as functional monomer, and 2,2′-azobisisobutyronitrile as a radical initiator. The IIP was characterized by Fourier transform infrared spectroscopy and scanning electron microscopy (FTIR). Uranium determination was performed using digital imaging (ID), and some experimental conditions (sample pH, eluent concentration, and sampling flow rate) were optimized using a two-level full factorial design and Doelhert response surface methodology. Thus, using the optimized conditions, the system allowed the determination of uranium with detection and quantification limits of 2.55 and 8.51 µg L−1, respectively, and a pre-concentration factor of 8.2. All parameters were determined using a 25 mL sample volume. The precision expressed as relative deviation (RSD%) was 3.5% for a solution with a concentration of 50 µg L−1. Given this, the proposed method was used for the determination of uranium in four samples of natural waters collected in the city of Caetité, Bahia, Brazil. The concentrations obtained ranged from 35 to 75.4 μg L−1. The accuracy was evaluated by the addition/recovery test, and the values found ranged between 91 and 109%.
2 July 2024 in Boletín de la Sociedad Española de Cerámica y Vidrio