Chunyuan Tian

Chunyuan Tian


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2022 in Food Chemistry
Verified
Journal Article
Closed access
XGXueqing Gao
Xueqing Gao
XGXiaowen Gu
Xiaowen Gu
QMQi Min
Qi Min
YWYueyue Wei
Yueyue Wei
CTChunyuan Tian
Chunyuan Tian
FLFeng Luan
Feng Luan

13 November 2023 in Food Chemistry
Verified
Journal Article
Closed access
XYXidian Yue
Xidian Yue
QHQing Hua
Qing Hua
WZWenjuan Zhang
Wenjuan Zhang
FTFeiyan Tang
Feiyan Tang
XWXiaobing Wang
Xiaobing Wang
CTChunyuan Tian
Chunyuan Tian

28 May 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
XLXin Li
Xin Li
XWXiaoling Wang
Xiaoling Wang
WGWei Guo
Wei Guo
YWYunfei Wang
Yunfei Wang
QHQing Hua
Qing Hua
LZLijun Zhao
Lijun Zhao
In this paper, a novel, accurate, sensitive and rapid ratiometric fluorescent sensor was fabricated using a copper nanoclusters@infinite coordination polymer (ICP), specifically, terbium ion-guanosine 5’-disodium (Cu NCs@Tb-GMP) nanocomposites as the ratiometric fluorescent probe, to detect alkaline phosphatase (ALP) in water. The fluorescence probe was characterized by scanning electron microscopy, transmission electron microscopy, X-ray photoelectron spectroscopy, and Fourier transform infrared spectroscopy. The experimental results showed that, compared with Tb-GMP fluorescent sensors, Cu ratiometric fluorescent sensors based on NCs encapsulated in Tb-GMP had fewer experimental errors and fewer false-positive signals and were more conducive to the sensitive and accurate detection of ALP. In addition, the developed fluorescent probe had good fluorescence intensity, selectivity, repeatability and stability. Under optimized conditions, the ratiometric fluorescent sensor detected ALP in the range of 0.002–2 U mL−1 (R2 = 0.9950) with a limit of detection of 0.002 U mL−1, and the recovery of ALP from water samples was less than 108.2%. These satisfying results proved that the ratiometric fluorescent probe has good application prospects and provides a new method for the detection of ALP in real water samples.

26 July 2022 in The Analyst
Verified
Journal Article
Closed access
PDF file
FTFeiyan Tang
Feiyan Tang
QHQing Hua
Qing Hua
XWXiaobin Wang
Xiaobin Wang
FLFeng Luan
Feng Luan
LWLi Wang
Li Wang
CTChunyuan Tian
Chunyuan Tian
As an efficient and easily available pesticide, imidacloprid (IM) has been widely used in agriculture to kill pests. However, threats to the ecological environment are becoming increasingly prominent, caused by abuse and pesticide residues. This paper reports a sensitive electrochemiluminescence (ECL) sensor based on upconverting nanoparticle functional zeolite imidazolate framework (UCNPs@ZIF-8) nanocomposites combined with molecularly imprinted polymers (MIPs) to successfully achieve the quantitative detection of IM. The composites exhibited a certain multi-faceted prismatic structure and the effective binding of UCNPs was demonstrated by characterization technology. In addition, a sensor with MIPs/UCNPs@ZIF-8/GCE as the working electrode exhibited outstanding ECL performance, including a strong and stable signal and excellent selectivity under optimal conditions. This sensor showed a good linear response to IM over a wide concentration range (0.1 ng L−1–1 mg L−1), with a limit of detection as low as 0.01 ng L−1. More significantly, it was successfully applied to the determination of IM concentration levels in food, which provides broad application prospects for the construction of pesticide ECL sensors.

19 December 2023 in Molecules
Verified
Journal Article
Open access
PDF file
CTChunyuan Tian
Chunyuan Tian
FTFeiyan Tang
Feiyan Tang
WGWei Guo
Wei Guo
MWMinggang Wei
Minggang Wei
LWLi Wang
Li Wang
FLFeng Luan
Feng Luan
The excessive concentration of heavy-metal mercury ions (Hg2+) in the environment seriously affects the ecological environment and even threatens human health. Therefore, it is necessary to develop rapid and low-cost determination methods to achieve trace detection of Hg2+. In this paper, an Electrochemiluminescence (ECL) sensing platform using a functionalized rare-earth material (cerium oxide, CeO2) as the luminescent unit and an aptamer as a capture unit was designed and constructed. Using the specific asymmetric matching between Hg2+ and thymine (T) base pairs in the deoxyribonucleic acid (DNA) single strand, the “T−Hg−T” structure was formed to change the ECL signal, leading to a direct and sensitive response to Hg2+. The results show a good linear relationship between the concentration and the response signal within the range of 10 pM–100 µM for Hg2+, with a detection limit as low as 0.35 pM. In addition, the ECL probe exhibits a stable ECL performance and excellent specificity for identifying target Hg2+. It was then successfully used for spiked recovery tests of actual samples in the environment. The analytical method solves the problem of poor Hg2+ recognition specificity, provides a new idea for the efficient and low-cost detection of heavy-metal pollutant Hg2+ in the environment, and broadens the prospects for the development and application of rare-earth materials.

10 March 2022 in The Analyst
Verified
Journal Article
Closed access
PDF file
XWXiaobin Wang
Xiaobin Wang
YZYuqing Zhao
Yuqing Zhao
QHQing Hua
Qing Hua
JLJiaojiao Lu
Jiaojiao Lu
FTFeiyan Tang
Feiyan Tang
CTChunyuan Tian
Chunyuan Tian
In this paper, the electrochemiluminescence (ECL) of sulfur quantum dots (SQDs) in a potassium persulfate cathodic co-reactant was studied. Based on the selective quenching of the ECL emission from the SQDs by β-nicotinamide adenine dinucleotide (NADH), an ultrasensitive ECL biosensor with NADH as an important parameter was established for the highly sensitive and selective detection of total bacterial count (TBC). A linear response between the ECL intensity and the NADH concentration in the range of 1 pM to 10 μM was obtained, thus achieving a detection limit of 1 pM. As the content of NADH in cells is positively correlated with the TBC, a sensor has been successfully applied to detect the TBC in actual water samples with a good recovery rate of 103–107 CFU mL−1. This study provides a green and feasible method for TBC detection in the environment.