Fei Hu

Dr. Fei Hu


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 December 2024 in Analytica Chimica Acta
Verified
Journal Article
Closed access
TZTianyi Zhang
Tianyi Zhang
XWXiaoqin Wang
Xiaoqin Wang
YJYingtao Jiang
Yingtao Jiang
YZYunyun Zhang
Yunyun Zhang
SZShuhao Zhao
Shuhao Zhao
NPNiancai Peng
Niancai Peng

7 June 2023 in The Analyst
Verified
Journal Article
Closed access
PDF file
YYYuanyang Yao
Yuanyang Yao
SZShuhao Zhao
Shuhao Zhao
YLYan Liang
Yan Liang
Fei HuFei Hu
Fei Hu
PNPeng Niancai
Peng Niancai
A novel method with high accuracy and lower resource consumption for droplets detection and can be used on mobile devices.

8 February 2020 in Micromachines
Verified
Journal Article
Open access
PDF file
ZZZengming Zhang
Zengming Zhang
SZShuhao Zhao
Shuhao Zhao
Fei HuFei Hu
Fei Hu
GYGuangpu Yang
Guangpu Yang
JLJuan Li
Juan Li
PNPeng Niancai
Peng Niancai
The sensitive quantification of low-abundance nucleic acids holds importance for a range of clinical applications and biological studies. In this study, we describe a facile microfluidic chip for absolute DNA quantifications based on the digital loop-mediated isothermal amplification (digital LAMP) method. This microfluidic chip integrates a cross-flow channel for droplet generation with a micro-cavity for droplet tiling. DNA templates in the LAMP reagent were divided into ~20,000 water-in-oil droplets at the cross-flow channel. The droplets were then tiled in the micro-cavity for isothermal amplification and fluorescent detection. Different from the existing polydimethylsiloxane (PDMS) microfluidic chips, this study incorporates gold nanoparticles (AuNPs) into PDMS substrate through silica coating and dodecanol modification. The digital LAMP chip prepared by AuNPs-PDMS combines the benefits of the microstructure manufacturing performance of PDMS with the light-to-heat conversion advantages of AuNPs. Upon illumination with a near infrared (NIR) LED, the droplets were stably and efficiently heated by the AuNPs in PDMS. We further introduce an integrated device with a NIR heating unit and a fluorescent detection unit. The system could detect HBV (hepatitis B virus)-DNA at a concentration of 1 × 101 to 1 × 104 copies/μL. The LED-driven digital LAMP chip and the integrated device; therefore, demonstrate high accuracy and excellent performance for the absolute quantification of low-abundance nucleic acids, showing the advantages of integration, miniaturization, cost, and power consumption.

8 May 2025 in Analytica Chimica Acta
Verified
Journal Article
Closed access
SZShuhao Zhao
Shuhao Zhao
XGXiaotong Guan
Xiaotong Guan
LPLixin Peng
Lixin Peng
KLKaihui Liu
Kaihui Liu
TZTianyi Zhang
Tianyi Zhang
Fei HuFei Hu
Fei Hu

8 October 2024 in Biosensors
Verified
Journal Article
Open access
PDF file
ZYZhao Yao
Zhao Yao
Niancai PengNiancai Peng
Niancai Peng
WGWeizhuo Gao
Weizhuo Gao
Fei HuFei Hu
Fei Hu
CZChuanyu Zhang
Chuanyu Zhang
XWXueyong Wei
Xueyong Wei
In this work, we report a study of a zinc sulfide (ZnS) nanocrystal and reduced graphene oxide (RGO) nanocomposite-based non-enzymatic uric acid biosensor. ZnS nanocrystals with different morphologies were synthesized through a hydrothermal method, and both pure nanocrystals and related ZnS/RGO were characterized with SEM, XRD and an absorption spectrum and resistance test. It was found that compared to ZnS nanoparticles, the ZnS nanoflakes had stronger UV light absorption ability at the wavelength of 280 nm of UV light. The RGO significantly enhanced the electron transfer efficiency of the ZnS nanoflakes, which further led to a better photoelectrochemical property of the ZnS/RGO nanocomposites. The ZnS nanoflake/RGO nanocomposite-based biosensor showed an excellent uric acid detecting sensitivity of 534.5 μA·cm−2·mM−1 in the linear range of 0.01 to 2 mM and a detection limit of 0.048 μM. These results will help to improve non-enzymatic biosensor properties for the rapid and accurate clinical detection of uric acid.

13 November 2024 in Biosensors
Verified
Journal Article
Open access
PDF file
FWFangning Wang
Fangning Wang
Fei HuFei Hu
Fei Hu
YZYunyun Zhang
Yunyun Zhang
XLXichen Li
Xichen Li
QMQin Ma
Qin Ma
Niancai PengNiancai Peng
Niancai Peng
Clustered regularly interspaced short palindromic repeats (CRISPR) molecular diagnostic technology is one of the most reliable diagnostic tools for infectious diseases due to its short reaction time, high sensitivity, and excellent specificity. However, compared with fluorescent polymerase chain reaction (PCR) technology, CRISPR molecular diagnostic technology lacks high-throughput automated instrumentation and standardized detection reagents for high sensitivity, limiting its large-scale clinical application. In this study, a high-throughput automated device was developed by combining reagent lyophilization, extraction-free technology, and a one-pot consumable system. This innovative approach enabled the rapid sample-in-result-out detection of 48 samples in 25 min and demonstrated high sensitivity and specificity for the qualitative analysis of clinical samples. The obtained results show that the detection limit of the designed system for African swine fever virus (ASFV) is 0.5 copies/μL. As a proof concept, a single-tube dual-target nucleic acid detection method was developed, achieving a detection limit of 5 copies/μL for the ORF1ab and N genes of severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) within 45 min. The method is highly specific, reliable, and stable, providing a feasible solution for the clinical application of CRISPR nucleic acid detection technology.