Problem: Real-time process data and destructive test data were collected and merged from a wood-composite manufacturer in the southeastern US for the purpose of developing real-time predictive models for strength properties of manufactured particleboard. Sensor malfunction and other real-time data problems lead to null fields in the company's data warehouse, resulting in information loss. Many manufacturers attempt to build accurate predictive models excluding entire records with null fields or use summary statistics such as the average or median in place of the null field. However, predictive-model errors in validation may be higher in the presence of information loss and may misguide the production process. Approach: This paper summarizes an application of missing-data imputation methods in predictive modeling of a wood-composite manufacturing process. Variable selection was applied prior to imputing missing data. Two missing data-imputation methods were selected after comparing six possible methods. Predictive models of imputed data were developed using partial least squares regression (PLSR) and were compared with models developed from nonimputed data. Results: Maximum–likelihood-based imputation using the expectation-maximization (EM) algorithm and multiple imputation (MI) using Markov Chain Monte Carlo (MCMC) simulation achieved lower root mean-square error of prediction results than imputation based on the mean/median substitution, last-observation-carried-forward (LOCF), or a “hot-deck” method using single imputation. Predictive models based on the imputed dataset generated more precise prediction results than models based on nonimputed datasets. Outcomes of the study included avoiding rework and scrap when model predictions alerted of an imminent strength failure and minor reductions were made in resin input set points. Senior management of the company indicated that a savings occurred as a result of the study from lower resin usage (the second highest cost component of manufactured product).
19 June 2015 in IEEE Transactions on Biomedical Engineering
Objective: In this paper, we assess the feasibility of using two detectors in a slot-scanning digital radiography system to acquire images for measuring bone mineral density (BMD) of the middle phalanx of the middle finger using dual-energy X-ray absorptiometry (DXA). Methods: Simulations were used to evaluate the spectral separation of the low- and high-energy spectra and detective quantum efficiency was used for assessing image quality. Scan parameters were chosen to optimize spectral separation, image quality, and radiation dose. We introduce the measurement of volumetric BMD (vBMD) using basis material decomposition. We assess the accuracy of our methods by comparing measurements taken using bone images against reference data derived from subsequent incineration of the bones. In vivo scans were conducted to evaluate the system precision (repeatability) and agreement with a clinical densitometer. Results: Average errors for bone mineral content (BMC), areal BMD (aBMD), and vBMD were 4.85%, 5.49%, and 12.77%, respectively. Our system had good agreement with a clinical densitometer based on concordance correlation coefficient values of 0.92 and 0.98 for aBMD and BMC, respectively. Precision studies yielded coefficient of variation (CV) values of 1.35% for aBMD, 1.48% for BMC, and 1.80% for vBMD. The CV values of all measurements were within 2%, indicating that the methods have clinically acceptable precision. Conclusion: We conclude that our techniques yield bone measurements with high accuracy, clinically acceptable precision, and good agreement with a clinical densitometer. Significance: We have shown the clinical potential of phalangeal DXA measurements of aBMD and vBMD on a slot-scanning digital radiography system.
After more than a decade since the introduction of Statistical Engineering by Roger Hoerl and Ronald Snee, a group of leading applied statisticians from academia, industry, and government were invited to discuss their perspectives on progress made, the current status of this important movement, and what future Statistical Engineering holds on the path forward in a series of two panel discussion papers. In this first article, the invited panelists focus their discussion on the past and present of Statistical Engineering. They discuss notable advances and current obstacles to progress. They also consider the unique value added by Statistical Engineering, and the possible addition of decision making to the body of knowledge. The format of the article consists of the posed questions from the moderators, a summary of key ideas from all the panelists, and then the individual detailed answers. The goal of this series of articles is to inspire statisticians to consider their possible role to advance the adoption of Statistical Engineering to solve important problems.
Background: The purpose of this study was to evaluate the effectiveness and safety of the PreserFlo™ microshunt (PMS) using a 25-Gauge vs. 27-Gauge needle tract. Methods: This is a prospective postoperative examination of 60 glaucoma eyes that received a PMS. The main outcome measures were intraocular pressure (IOP), glaucoma drug score (GDS), Kaplan–Meier success rates, complications, and secondary intervention rates. Two subgroups were formed for data comparison: 27-Gauge (27G), and 25-Gauge (25G). Success was defined as IOP < 18 mmHg together with ≥20% IOP reduction with medication allowed (qualified success = QS18) or not (full success = FS18). Results: IOP and GDS were reduced from baseline to the 1-year study visit as follows: All eyes from 23.4 ± 8.6 mmHg (3.1 ± 0.9) to 15.1 ± 5.9 mmHg (0.8 ± 1.1); 25G from 24.2 ± 7.3 mmHg (3.0 ± 0.8) to 12.7 ± 2.7 mmHg (0.5 ± 0.8); and 27G from 23.1 ± 9.2 mmHg (3.1 ± 1.0) to 16.2 ± 6.7 mmHg (0.9 ± 1.2). IOP at one year was lower in the 25G group compared to the 27G group (p = 0.035). Bleb needling was required in eight (13.3%) eyes and open bleb revisions in three (5.0%). Transient hypotony occurred in 21% and choroidal effusion in 8% of all eyes. Choroidal effusions were more frequent in the 25G group (21%) compared to the 27G group (2%, p = 0.031). One-year success rates were significantly higher in the 25G group compared to the 27G group for both QS18 (25G: 67.9% vs. 27G: 35.7%, p = 0.002) and FS18 (25G: 63.6% vs. 27G: 29.2%, p = 0.007). Conclusions: The PreserFlo microshunt is an effective and safe glaucoma surgery with a low rate of bleb revisions or needlings. We show that the 25G needle tract might be more efficient for IOP control at the cost of increased IOP-related complications compared to 27G.
31 August 2024 in American Journal of Ophthalmology
To introduce and validate a novel substantially lower-priced and rapid swept-source investigational optical biometer in healthy and cataractous eyes, using a thermally tuned laser diode used extensively in cell phones and data communication as an alternative swept source. Prospective accuracy, validity, and reliability analysis. A total of 60 eyes of 59 subjects (29 eyes of 29 healthy subjects and 31 eyes of 30 cataract patients) were enrolled in a prospective comparative study at the Vienna General Hospital between August 2021 and April 2023. Averaged intraocular distances were acquired in 2.5 seconds from datasets consisting of 5000 consecutive A-scans at a single position by a low-cost swept-source optical biometry (SSOB) system. Instrument repeatability was assessed via standard deviations (SDs) and coefficients of variation (CoVs) of parameters such as axial length (AL), anterior chamber depth (ACD), lens thickness (LT), and central corneal thickness (CCT). Healthy subjects and cataract patients were subsequently measured on the same day with the SSOB and a referential partial coherence interferometry (PCI) biometer (IOLMaster 500) to establish AL inter-device correlation (r) for instrument calibration. AL and ACD as shared parameters between both biometers were evaluated for their limits of agreements (LoA) using Bland-Altman analysis. Repeated measurements of AL, ACD, LT, and CCT revealed SDs of 18 µm, 12 µm, 12 µm, and 10 µm, respectively. All parameters except for CCT had a COV 0.99). The 95% LoAs between both biometers were -0.14 to 0.13 mm for AL and -0.28 to 0.25 mm for ACD. Optical biometry using a thermally tunable VCSEL swept-source light source has the potential to provide clinically relevant biometric parameters at an unprecedented 100-fold lower price point than currently used state-of-the-art optical biometers, paving the way for compact devices in remote care settings.