Celine Moede

Ms. Celine Moede

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 April 2025 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
INIna Nitschke
Ina Nitschke
CMCeline Moede
Celine Moede
Andreas KoenigAndreas Koenig
Andreas Koenig
BSBernhard A. J. Sobotta
Bernhard A. J. Sobotta
WHWerner Hopfenmüller
Werner Hopfenmüller
JJJulia Jockusch
Julia Jockusch
Objectives: This study aimed to establish reference values for bite force in individuals with various prosthetic restorations and to examine the relationship between prosthetic treatment groups (PTGs) and bite force as an indicator of masticatory muscle function. Materials and Methods: In a cross-sectional study from November 2021 to March 2023, 198 participants aged 18 to 95 years were recruited from multiple dental and geriatric centers. The participants were assigned to seven PTGs based on their dental and prosthetic statuses. Bite force was measured using the Occlusal Force Meter GM10, with three recordings on each side of the jaw, and analyzed using ANOVA. Results: The bite force decreased with fewer teeth and the transition from fixed to removable dentures. Fully dentate participants exhibited the highest bite forces, differing significantly from the other groups (p < 0.001). For the fully dentate individuals (547 ± 240 N), the bite force decreased progressively with the extent of prosthetic restoration, reaching 55 ± 45 N in edentulous individuals with complete dentures in both jaws. However, edentulous participants with two interforaminal implants demonstrated higher bite forces than those with partial dentures. Conclusions: Bite force is significantly impacted by prosthetic restoration type. Fully dentate individuals have the highest bite forces, while edentulous patients with implant-supported dentures also show considerable bite forces, similar to those with partial dentures.

21 November 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
INIna Nitschke
Ina Nitschke
CMCeline Moede
Celine Moede
WHWerner Hopfenmüller
Werner Hopfenmüller
BSBernhard A. J. Sobotta
Bernhard A. J. Sobotta
AKAndreas Koenig
Andreas Koenig
JJJulia Jockusch
Julia Jockusch
Background: this study aims to validate two occlusal-force-measuring devices by comparing them to a universal testing machine and assessing their reliability across various dental and prosthetic groups. The research comprised two parts: part 1 assessed the measurement accuracy of the Occlusal Force Meter GM 10® (OFM) (Morita, Nagano Keiki, Higashimagome, Ohta-ku, Tokyo, Japan) and a prototype (PRO) by comparing them to a calibrated universal testing machine (ZWICK). Part 2 involved analyzing the devices’ reliability based on clinical bite force measurements from study participants. Results: both devices become more accurate and reliable compared to the ZWICK over time of usage. Additionally, higher deviation from the ZWICK can be observed for higher values of forces applied and vice versa for both devices. The PRO’s intraoral alignment influences its mean values compared to the OFM in different dental and prosthetic groups. Conclusion: both devices had limitations and required quadratic function calibration, making them suitable only for progression measurements. The study concludes that both the OFM and PRO devices can measure occlusal forces with improved accuracy over time. Intraoral alignment should be considered. Their easy-to-use clinical application would allow a more widespread use of masticatory function diagnosis, which could indicate the need for treatment and improve treatment planning.