Mar Puyol

Dr. Mar Puyol

Universitat Autònoma de Barcelona (UAB), Edifici Cn s/n, 08193 Bellaterra, Barcelona, Spain

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2015 in Analytica Chimica Acta
Verified
Journal Article
Open access
ACAntonio Calvo-López
Antonio Calvo-López
OYOriol Ymbern
Oriol Ymbern
MPMar Puyol
Mar Puyol
JCJoan Manel Casalta
Joan Manel Casalta
JAJulian Alonso-Chamarro
Julian Alonso-Chamarro
The design, construction and evaluation of a versatile cyclic olefin copolymer (COC)-based continuous flow potentiometric microanalyzer to monitor the presence of ammonium ion in recycling water processes for future manned space missions is presented. The microsystem integrates microfluidics, a gas-diffusion module and a detection system in a single substrate. The gas-diffusion module was integrated by a hydrophobic polyvinylidene fluoride (PVDF) membrane. The potentiometric detection system is based on an all-solid state ammonium selective electrode and a screen-printed Ag/AgCl reference electrode. The analytical features provided by the analytical microsystem after the optimization process were a linear range from 0.15 to 500 mg L(-1) and a detection limit of 0.07 ± 0.01 mg L(-1). Nevertheless, the operational features can be easily adapted to other applications through the modification of the hydrodynamic variables of the microfluidic platform.

5 September 2014 in Analytical and Bioanalytical Chemistry
Verified
Journal Article
Closed access
PDF file
MBMiguel Berenguel-Alonso
Miguel Berenguel-Alonso
XGXavier Granados
Xavier Granados
Jordi FaraudoJordi Faraudo
Jordi Faraudo
JAJulian Alonso-Chamarro
Julian Alonso-Chamarro
MPMar Puyol
Mar Puyol

17 November 2022 in Talanta
Verified
Journal Article
Open access
ACAntonio Calvo-López
Antonio Calvo-López
EAEva Arasa-Puig
Eva Arasa-Puig
JAJulián Alonso-Chamarro
Julián Alonso-Chamarro
MPMar Puyol
Mar Puyol

2 April 2009 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
LRLaia Rivera
Laia Rivera
DIDavid Izquierdo
David Izquierdo
IGIgnacio Garcés
Ignacio Garcés
ISIñigo Salinas
Iñigo Salinas
JAJulian Alonso-Chamarro
Julian Alonso-Chamarro
MPMar Puyol
Mar Puyol

25 September 2017 in SLAS Technology
Verified
Journal Article
Closed access
MBMiguel Berenguel-Alonso
Miguel Berenguel-Alonso
MSMaria Sabés-Alsina
Maria Sabés-Alsina
RMRoser Morató
Roser Morató
OYOriol Ymbern
Oriol Ymbern
LRLaura Rodríguez-Vázquez
Laura Rodríguez-Vázquez
Manel Lopez-BejarManel Lopez-Bejar
Manel Lopez-Bejar

29 March 2022 in Analytica Chimica Acta
Verified
Journal Article
Open access
ACAntonio Calvo-López
Antonio Calvo-López
BRBeatriz Rebollo-Calderon
Beatriz Rebollo-Calderon
AOAida Ormazábal
Aida Ormazábal
RARafael Artuch
Rafael Artuch
JRJavier Rosell-Ferrer
Javier Rosell-Ferrer
MPMar Puyol
Mar Puyol
Some inborn errors of metabolism and other diseases can result in increasing blood ammonium (hyperammonemia episodes), which can cause serious neurological complications in patients or even death. Early diagnosis, follow up and treatment are essential to minimize irreversible damages in brain. Currently, adequate analytical instrumentation for the necessary ammonium bedside determination is not available in all health centers but only in clinical laboratories of reference hospitals. We therefore have developed a low cost and portable potentiometric Point-of-Care microanalyzer (POC) to address this problem. It consists of a cyclic olefin copolymer-based microanalyzer, the size of a credit card and working in continuous flow, which integrates microfluidics, a gas-diffusion module and a potentiometric detection system. The analytical features achieved are a linear range from 30 to 1000 μmol L-1 NH4+, a detection limit of 18 μmol L-1 NH4+ and a required sample volume of 100 μL, which comply with the medical requirements. Plasma and blood samples are analyzed with no significant differences observed between ammonium concentrations obtained with both the proposed microanalyzer and the reference method. This demonstrates the value of the developed POC for bedside clinical applications.