Sample preparation for mass spectroscopy typically involves several liquid and solid phase clean-ups, extractions, and other unit operations, which are labour-intensive and error-prone. We demonstrate a centrifugal microfluidic platform that automates the whole blood sample’s preparation and clean-up by combining traditional liquid-phase and multiple solid-phase extractions for applications in mass spectroscopy (MS)-based small molecule detection. Liquid phase extraction was performed using methanol to precipitate proteins in plasma separated from a blood sample under centrifugal force. The preloaded solid phase composed of C18 beads then removed lipids with a combination of silica particles, which further cleaned up any remaining proteins. We further integrated the application of this sample prep disc with matrix-assisted laser desorption/ionization (MALDI) MS by using glancing angle deposition films, which further cleaned up the processed sample by segregating the electrolyte background from the sample salts. Additionally, hydrophilic interaction liquid chromatography (HILIC) MS was employed for detecting targeted free amino acids. Therefore, several representative ionic metabolites, including several amino acids and organic acids from blood samples, were analysed by both MALDI-MS and HILIC-MS to demonstrate the performance of this sample preparation disc. The fully automated blood sample preparation procedure only took 35 mins, with a throughput of three parallel units.
An increase in the levels of progesterone (P4) in humans due to excessive exposure through hormone treatment, food products, or drinking water is associated with several side effects. Detection methods like enzyme linked immunosorbent assay (ELISA) and chromatography have been traditionally used for detection of P4. However, the need for cost-effective and rapid detection from food and environmental samples especially at the point-of-need, without the need for bulky and complicated instrumentation remains pivotal. In order to rapidly detect P4 from samples, we demonstrate here a simple-to-use, cost-efficient and user-friendly microfluidic device with an integrated etalon sensor surface. The platform integrates the sample handling and reagent flow control on a simple spindle motor allowing for direct delivery of aqueous sample to the device, integrated sample cleanup, followed by on-disc analysis of the embedded etalon sensor films using a simple camera. We also demonstrate image color analysis of the etalon sensor surface, better suited for point-of-care/on-site applications instead of traditional reflectance spectrum analysis. The total sample preparation and detection automation on the microfluidic disc takes only about 1 hour with detection limit as low as 5.65pg/ml. Given the increasingly widespread prevalence of hormones and endocrine disruptive chemicals and their link to numerous adverse human health and environmental outcomes, the platform should offer significant applications in environmental monitoring, food/drug regulation and clinical diagnostics.