Marco D'arienzo

Dr. Marco D'arienzo

orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2020 in Biosafety and Health
Verified
Journal Article
Open access
MDMarco D'arienzo
Marco D'arienzo
ACAngela Coniglio
Angela Coniglio
As of March 12th Italy has the largest number of SARS-CoV-2 cases in Europe as well as outside China. The infections, first limited in Northern Italy, have eventually spread to all other regions. When controlling an emerging outbreak of an infectious disease it is essential to know the key epidemiological parameters, such as the basic reproduction number R0, i.e. the average number of secondary infections caused by one infected individual during his/her entire infectious period at the start of an outbreak. Previous work has been limited to the assessment of R0 analyzing data from the Wuhan region or Mainland China. In the present study the R0 value for SARS-CoV-2 was assessed analyzing data derived from the early phase of the outbreak in Italy. In particular, the spread of SARS-CoV-2 was analyzed in 9 cities (those with the largest number of infections) fitting the well-established SIR-model to available data in the interval between February 25–March 12, 2020. The findings of this study suggest that R0 values associated with the Italian outbreak may range from 2.43 to 3.10, confirming previous evidence in the literature reporting similar R0 values for SARS-CoV-2.

1 June 2012 in Nuclear Medicine Communications
Verified
Journal Article
Closed access
MDMarco D'arienzo
Marco D'arienzo
PCPaola Chiaramida
Paola Chiaramida
LCLaura Chiacchiararelli
Laura Chiacchiararelli
ACAngela Coniglio
Angela Coniglio
RCRoberto Cianni
Roberto Cianni
OBOreste Bagni
Oreste Bagni
Objectives The decay of 90Y has a minor branch to the O+ first excited state of 89Zr, the de-excitation of which to the fundamental state is followed by a β+–β− emission that has been used recently for biodistribution assessment after selective internal radiotherapy (SIRT) treatments. The purpose of the present study is to demonstrate the feasibility of 90Y PET imaging for dose assessment after radioembolization with 90Y microspheres. Methods Activity quantification was validated through preliminary phantom studies using a cylindrical body phantom composed of six inserts of different volumes filled with a calibrated amount of 90Y microspheres. A GE Discovery ST PET/CT scanner provided with bismuth germinate (BGO) crystals was used for image acquisition. Images were reconstructed with an ordered subset expectation–maximization method. The effect of object size and the effect of the number of iterations on dose evaluation and volume recovery were investigated. Microsphere dose distribution was then evaluated on one patient (one lesion) who underwent liver SIRT treatment. Dose calculations were made with a MATLAB-based code developed in our department. Dedicated Monte Carlo calculations were executed to evaluate dose S-values for the 90Y source. The activity distribution derived from 90Y PET acquisitions was convolved with the voxel S-values to obtain a three-dimensional absorbed dose distribution and dose–volume histograms. Results Dosimetry studies carried out on the body phantom with ordered subset expectation–maximization algorithm, three iterations, provided an accuracy of 7.62% in determining the absorbed dose in the largest insert. The dose difference increases as the insert size reduces. Preliminary results on a patient provided a high-resolution absorbed dose distribution map. An average dose of 139.3 Gy was evaluated for the tumor area, with a maximum dose as high as 237.9 Gy. The absorbed dose to the healthy liver was below the tolerance dose of 35 Gy (33.8 Gy). A clear correlation between absorbed dose and tumor response was observed at 18F-fluorodeoxyglucose PET acquired 6 months after treatment. Conclusion According to our experience, 90Y PET is a promising and reliable technique for microsphere dose assessment and might pave the way for a patient-specific PET-based dosimetry after liver SIRT treatments.

28 November 2017 in EJNMMI Research
Verified
Journal Article
Open access
PDF file
MDMarco D'arienzo
Marco D'arienzo
MPMaria Pimpinella
Maria Pimpinella
Marco CapogniMarco Capogni
Marco Capogni
VCVanessa De Coste
Vanessa De Coste
Luca FilippiLuca Filippi
Luca Filippi
OBOreste Bagni
Oreste Bagni
PET/CT has recently been shown to be a viable alternative to traditional post-infusion imaging methods providing good quality images of 90Y-laden microspheres after selective internal radiation therapy (SIRT). In the present paper, first we assessed the quantitative accuracy of 90Y-PET using an anthropomorphic phantom provided with lungs, liver, spine, and a cylindrical homemade lesion located into the hepatic compartment. Then, we explored the accuracy of different computational approaches on dose calculation, including (I) direct Monte Carlo radiation transport using Raydose, (II) Kernel convolution using Philips Stratos, (III) local deposition algorithm, (IV) Monte Carlo technique (MCNP) considering a uniform activity distribution, and (V) MIRD (Medical Internal Radiation Dose) analytical approach. Finally, calculated absorbed doses were compared with those obtained performing measurements with LiF:Mg,Cu,P TLD chips in a liquid environment. Our results indicate that despite 90Y-PET being likely to provide high-resolution images, the 90Y low branch ratio, along with other image-degrading factors, may produce non-uniform activity maps, even in the presence of uniform activity. A systematic underestimation of the recovered activity, both for the tumor insert and for the liver background, was found. This is particularly true if no partial volume correction is applied through recovery coefficients. All dose algorithms performed well, the worst case scenario providing an agreement between absorbed dose evaluations within 20%. Average absorbed doses determined with the local deposition method are in excellent agreement with those obtained using the MIRD and the kernel-convolution dose calculation approach. Finally, absorbed dose assessed with MC codes are in good agreement with those obtained using TLD in liquid solution, thus confirming the soundness of both calculation approaches. This is especially true for Raydose, which provided an absorbed dose value within 3% of the measured dose, well within the stated uncertainties. Patient-specific dosimetry is possible even in a scenario with low true coincidences and high random fraction, as in 90Y–PET imaging, granted that accurate absolute PET calibration is performed and acquisition times are sufficiently long. Despite Monte Carlo calculations seeming to outperform all dose estimation algorithms, our data provide a strong argument for encouraging the use of the local deposition algorithm for routine 90Y dosimetry based on PET/CT imaging, due to its simplicity of implementation.

MDMarco D'arienzo
Marco D'arienzo
SMStefano G. Masciullo
Stefano G. Masciullo
VSVitaliana De Sanctis
Vitaliana De Sanctis
Mattia Falchetto OstiMattia Falchetto Osti
Mattia Falchetto Osti
LCLaura Chiacchiararelli
Laura Chiacchiararelli
RERiccardo M. Enrici
Riccardo M. Enrici
The aim of the present paper is to compare the integral dose received by non-tumor tissue (NTID) in stereotactic body radiation therapy (SBRT) with modified LINAC with that received by three-dimensional conformal radiotherapy (3D-CRT), estimating possible correlations between NTID and radiation-induced secondary malignancy risk. Eight patients with intrathoracic lesions were treated with SBRT, 23 Gy × 1 fraction. All patients were then replanned for 3D-CRT, maintaining the same target coverage and applying a dose scheme of 2 Gy × 32 fractions. The dose equivalence between the different treatment modalities was achieved assuming α/β = 10Gy for tumor tissue and imposing the same biological effective dose (BED) on the target (BED = 76Gy10). Total NTIDs for both techniques was calculated considering α/β = 3Gy for healthy tissue. Excess absolute cancer risk (EAR) was calculated for various organs using a mechanistic model that includes fractionation effects. A paired two-tailed Student t-test was performed to determine statistically significant differences between the data (p ≤ 0.05). Our study indicates that despite the fact that for all patients integral dose is higher for SBRT treatments than 3D-CRT (p = 0.002), secondary cancer risk associated to SBRT patients is significantly smaller than that calculated for 3D-CRT (p = 0.001). This suggests that integral dose is not a good estimator for quantifying cancer induction. Indeed, for the model and parameters used, hypofractionated radiotherapy has the potential for secondary cancer reduction. The development of reliable secondary cancer risk models seems to be a key issue in fractionated radiotherapy. Further assessments of integral doses received with 3D-CRT and other special techniques are also strongly encouraged.

8 March 2013 in Atoms
Verified
Journal Article
Open access
PDF file
MDMarco D'arienzo
Marco D'arienzo
90Y is traditionally considered as a pure β– emitter. However, the decay of this radionuclide has a minor branch to the 0+ first excited state of 90Zr at 1.76 MeV, that is followed by a β+/β– emission. This internal pair production has been largely studied in the past because it is generated by a rare electric monopole transition (E0) between the states 0+/0+ of 90Zr. The positronic emission has been recently exploited for nuclear medicine applications, i.e. positron emission tomography (PET) acquisitions of 90Y-labelled radiopharmaceuticals, widely used as therapeutic agents in internal radiation therapy. To date, this topic is gaining increasing interest in the radiation dosimetry community, as the possibility of detecting β+ emissions from 90Y by PET scanners may pave the way for an accurate patient-specific dosimetry. This could lead to an explosion in scientific production in this field. In the present paper the historical background behind the study of the internal pair production of the 0+/0+ transition of 90Zr is presented along with most up to date measured branch ratio values. An overview of most recent studies that exploit β+ particles emitted from 90Y for PET acquisitions is also provided.

9 January 2020 in Environments
Verified
Journal Article
Open access
PDF file
SSSandro Sandri
Sandro Sandri
Gian Marco ContessaGian Marco Contessa
Gian Marco Contessa
MDMarco D'arienzo
Marco D'arienzo
MGManuela Guardati
Manuela Guardati
MGMaurizio Guarracino
Maurizio Guarracino
RVRosaria Villari
Rosaria Villari
The development of experimental nuclear fusion facilities and the systems connected to them currently involves the operation (or advanced design) of some large plants in the national territory. Devices such as neutron generators and plasma focus systems are also included. The machines developed to test the main components of these systems such as neutral beam generators (Neutral Beam Injector) and the experimental plants for thermonuclear fusion, mainly in the Tokamak configuration (toroidal geometry), are in the list. These applications are characterized by high neutron fluxes of high energy (typically 2.5 and 14 MeV from deuterium-deuterium and deuterium-tritium fusion reactions, respectively). They involve the production of radionuclides in the components of the machines and in the fluids used for targets’ cooling and in the primary containments. In many cases, the atmosphere of the rooms containing these structures is activated and may be affected by the dispersion of powders that are more or less radioactive. The present work addresses the issues mentioned so far, taking into consideration the real cases relating to the devices and the facilities in operation, under construction, and in the advanced design phase. The conclusions highlight the critical aspects related to the management of these types of waste, as well as the low or very low environmental impact, from a radiological point of view, of the examined facilities.