Komang Gede Yudi Arsana

Dr. Komang Gede Yudi Arsana

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
KAKomang Gede Yudi Arsana
Komang Gede Yudi Arsana
Giovanni Marco SaladinoGiovanni Marco Saladino
Giovanni Marco Saladino
BBBertha Brodin
Bertha Brodin
Muhammet S. ToprakMuhammet S. Toprak
Muhammet S. Toprak
HHHans Hertz
Hans Hertz
Diffraction-limited resolution and low penetration depth are fundamental constraints in optical microscopy and in vivo imaging. Recently, liquid-jet X-ray technology has enabled the generation of X-rays with high-power intensities in laboratory settings. By allowing the observation of cellular processes in their natural state, liquid-jet soft X-ray microscopy (SXM) can provide morphological information on living cells without staining. Furthermore, X-ray fluorescence imaging (XFI) permits the tracking of contrast agents in vivo with high elemental specificity, going beyond attenuation contrast. In this study, we established a methodology to investigate nanoparticle (NP) interactions in vitro and in vivo, solely based on X-ray imaging. We employed soft (0.5 keV) and hard (24 keV) X-rays for cellular studies and preclinical evaluations, respectively. Our results demonstrated the possibility of localizing NPs in the intracellular environment via SXM and evaluating their biodistribution with in vivo multiplexed XFI. We envisage that laboratory liquid-jet X-ray technology will significantly contribute to advancing our understanding of biological systems in the field of nanomedical research.

1 February 2020 in Review of Scientific Instruments
Verified
Journal Article
Open access
PDF file
MKM. Kördel
M. Kördel
KAKomang Gede Yudi Arsana
Komang Gede Yudi Arsana
HHHans Hertz
Hans Hertz
UVUlrich Vogt
Ulrich Vogt
We present a stability investigation of the Stockholm laboratory cryo soft x-ray microscope. The microscope operates at a wavelength of 2.48 nm and can image biological samples at liquid-nitrogen temperatures in order to mitigate radiation damage. We measured the stability of the two most critical components, sample holder and optics holder, in vacuo and at cryo temperatures at both short and long time scales with a fiber interferometer. Results revealed vibrations in the kHz range, originating mainly from a turbo pump, as well as long term drifts in connection with temperature fluctuations. With improvements in the microscope, earlier stability issues vanished and close-to diffraction-limited imaging could be achieved. Moreover, our investigation shows that fiber interferometers are a powerful tool in order to investigate position-sensitive setups at the nanometer level.

Verified
Journal Article
Open access
PDF file
KAKomang Gede Yudi Arsana
Komang Gede Yudi Arsana
MSMartin Svenda
Martin Svenda
HHHans M. Hertz
Hans M. Hertz
Soft X-ray microscopy (SXM) is a powerful technique for high-resolution biomedical imaging, enabling the observation of bio–nano interactions in near-native conditions without the need for heavy metal staining and fluorescence labeling. A laboratory soft X-ray microscope (LSXM) was developed to bridge the resolution gap between light microscopy and electron microscopy in cellular imaging. However, LSXMs employ a lower-brightness X-ray source in comparison to those operated in synchrotron facilities, which can negatively affect the contrast of X-ray micrographs. Therefore, proper sample preparation is essential to achieve optimal imaging results. This paper details an LSXM sample preparation protocol for investigating cellular nanoparticle uptake. Samples are prepared using optimized parameters for both manual plunge-freezing and automated vitrification, ensuring the rapid transition of biological material into a solid state with controllable thickness in the 5–10 μm range, preserving cellular structures and enabling optimal X-ray transmission for cellular imaging. We demonstrate the effectiveness of this protocol in facilitating the observation of nanoparticle uptake in two different biological samples: murine macrophages and acanthamoeba. Controlling ice thickness improves X-ray transmission through the specimen, enhancing the contrast and image quality of SXM.

22 July 2025 in Research Square
Verified
Preprint
Open access
PDF file
KAKomang Gede Yudi Arsana
Komang Gede Yudi Arsana
GSGiovanni Marco Saladino
Giovanni Marco Saladino
BBBertha Brodin
Bertha Brodin
MTMuhammet S Toprak
Muhammet S Toprak
HHHans M Hertz
Hans M Hertz
Silica-shell metal-core nanoparticles are gaining increasing attention as contrast agents in advanced biomedical imaging, e.g., x-ray fluorescence imaging. However, these nanoparticles often accumulate in the liver, posing a significant challenge to their delivery efficiency to the intended target. This accumulation is likely caused by macrophage activity in processing cellular waste products, invading microorganisms, and foreign nanomaterials. We employ laboratory soft x-ray microscopy to investigate the uptake and dynamics of molybdenum-core silica-shell nanoparticles (MoO2SiO2 NPs) in macrophages. A laboratory soft x-ray microscope (LSXM), capable of nanometer-scale imaging of intact cells in their near-native state, visualized the NP uptake and observed the NP localization in phagocytic organelles in cryo-fixated cells. Quantitative analysis of the size and number of intracellular phagocytic structures at different time points post NP exposure revealed MoO2SiO2 NPs' dissolution dynamics. The results were validated by fluorescence microscopy and UV-Vis spectroscopy. We conclude that the LSXM as a powerful technique for studying bio-nano interactions.