Ayben Şentürk

Dr. Ayben Şentürk

prosthodontics, Ankara University, Ankara, Turkey (Türkiye)
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2022 in Brazilian Oral Research
Verified
Journal Article
Open access
BABora Akat
Bora Akat
AŞAyben Şentürk
Ayben Şentürk
Mert OcakMert Ocak
Mert Ocak
MKMehmet Ali Kılıçarslan
Mehmet Ali Kılıçarslan
Mutlu ÖzcanMutlu Özcan
Mutlu Özcan
Although the effects of different intraoral scanners, model scanners, and CAM units on the marginal and internal fitting of restorations have been investigated, the effects of CAD software in particular has not been evaluated. The marginal and internal fit of indirect restorations may vary according to the CAD software used, even when using the same intraoral scanner and milling machine. The purpose of this study was to evaluate the marginal and internal fit of milled full ceramic crowns designed with three different CAD systems. Eleven typodont maxillary first premolar teeth were prepared and scanned using a 3Shape TRIOS Intraoral Dental Scanner. The obtained STL scan data were exported and used to design a full crown using three different CAD systems (CEREC, KaVo, and Planmeca). An independent milling unit was used to manufacture the crowns for each group (n = 11). The marginal and internal fit were evaluated for each restoration using 2D and 3D micro-CT analysis. For 2D analysis, 18 measurements for each sample were made, covering the marginal (Marginal Gap Buccal (MG-A), Marginal Gap Palatinal (MG-B), Finish Line Buccal (FL-A), Finish Line Palatinal (FA-B)) and internal fit locations (Axial Wall Buccal (AW-A), Axial Wall Palatinal (AW-B), Lingual Cusp (LC), Buccal Cusp (BC), and Occlusal Central Fossa (OCF)). Statistical analyses were performed using Open Source R Statistical Software (α = 0.05) The results of Duncan's multiple range test showed that the values for the marginal measurement points MG-A, MG-B, FL-A, and FL-B in the Planmeca group were significantly higher than the values obtained in the CEREC and KaVo groups (p < 0.05). In AW1, values of the CEREC group were found to be higher than those of the KaVo and Planmeca groups (p < 0.05). CAD software showed an effect on the marginal fit values of crowns whereas no significant difference was observed in terms of the internal fit, except for a single measurement point made from the buccal direction.

30 April 2024 in Odontology
Verified
Journal Article
Open access
PDF file
AŞAyben Şentürk
Ayben Şentürk
FAFunda Akaltan
Funda Akaltan
The aim of this study was to evaluate the effect of the All-on-4 design and 4 alternative implant-supported fixed prosthesis designs on stress distribution in implants, peri-implant bone, and prosthetic framework in the edentulous mandible under different loading conditions using three-dimensional finite element analysis (3D-FEA).Five different experimental finite element models (Model A (unsplinted 6), Model B (splinted 6), Model C (All-on-4), Model D (axial; 2 anterior, 2 posterior), and Model E (4 interforaminal)) were created. Three different loading conditions were applied (canine loading, unilateral I-loading, and unilateral II-loading). The highest minimum (Pmin) and the maximum (Pmax) principal stress values were acquired for cortical and trabecular bones; the highest von Mises (mvM) stress values were obtained for implants and metal frameworks. Model B and Model D showed the most favorable stress distribution. The All-on-4 design (Model C) also showed acceptable stress values close to those of Model B and Model D in the cortical and trabecular bones. In accordance with the stress values in the bone structure, the lowest stress values were measured in the implants and Co-Cr framework in Model B and Model D. The highest stress values in all structures were measured for unilateral loading- II, while the lowest values were found for canine loading. It was concluded that Model B and Model D experimental models showed better biomechanical performance in all structures. Furthermore, the use of a splinted framework, avoiding cantilevers, results in lower stress transmission. On the other hand, canine loading and unilateral loading-I exhibited the best loading conditions.

Verified
Journal Article
Open access
PDF file
SYSıla Yelekçi
Sıla Yelekçi
AŞAyben Şentürk
Ayben Şentürk
FAFunda Akaltan
Funda Akaltan
Background: Artificial tooth wear impacts prosthesis durability and function; understanding material–antagonist interactions guides clinical choices. Aim: This in-vitro study aimed to assess the wear behavior of isosit and nanohybrid composite resin artificial teeth when opposed to various antagonist materials using 3D volumetric wear analysis. Materials and Methods: Sixty specimens (n = 10 per group) were prepared from two artificial tooth materials and assigned to six antagonist combinations: isosit–isosit, isosit–nanohybrid composite, isosit–porcelain, nanohybrid composite–isosit, nanohybrid composite–nanohybrid composite, and nanohybrid composite–porcelain. Specimens were scanned before and after 600,000 chewing cycles using a structured-light 3D scanner. Volumetric wear was calculated by superimposing pre- and post-test scans. Data were analyzed using two-way ANOVA and Tukey’s HSD test (α = 0.05). Results: Porcelain antagonists produced the highest wear values (p < 0.05). No significant difference was found between isosit and nanohybrid antagonists (p > 0.05). Identical material pairings showed less wear, though differences were not statistically significant. Conclusions: Porcelain as an antagonist increased wear risk. Using identical materials bilaterally, such as isosit–isosit or nanohybrid–nanohybrid, may help reduce artificial tooth wear in removable prostheses.

22 April 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
AŞAyben Şentürk
Ayben Şentürk
BABora Akat
Bora Akat
Mert OcakMert Ocak
Mert Ocak
MKMehmet Ali Kılıçarslan
Mehmet Ali Kılıçarslan
KOKaan Orhan
Kaan Orhan
Background and Objectives: CBCT images have been successfully used for CAD/CAM crown restorations; however, their use for ceramic inlay restorations remains unclear. This study aimed to evaluate the marginal and internal fit of CAD/CAM ceramic inlay restorations fabricated using intraoral scanner, model scanner, and CBCT data. Materials and Methods: Inlay preparations were performed on 11 mandibular molar typodont teeth. The teeth were scanned using an intraoral scanner, an extraoral scanner, and CBCT (0.075 mm voxel size). CBCT-generated DICOM data were converted to STL format with dedicated software. All scan data were transferred to CAD software, and a total of 33 restorations were designed. Feldspathic ceramic blocks were used for milling. Micro-CT was employed to measure marginal and internal gaps, with 60 measurement points taken from three cross-sections per sample. Data were analyzed using ANOVA and Bonferroni tests (p < 0.05). Results: CBCT exhibited greater marginal and internal gap dimensions (mean: 169.27 ± 38.64 μm), which were approximately 60–70 μm higher than those of the intraoral (97.00 ± 10.1 μm) and model scanner groups (109.67 ± 9.72 μm), exceeding clinically acceptable limits (≤120 μm) (p < 0.05). Intraoral and model scanners showed similar, clinically acceptable results. Conclusions: CBCT was less accurate for inlay restorations, likely due to their complex geometry. Nevertheless, fabrication was possible, and further research may improve its clinical applicability.

21 September 2025 in Journal of Functional Biomaterials
Verified
Journal Article
Open access
PDF file
AŞAyben Şentürk
Ayben Şentürk
BABora Akat
Bora Akat
FGFehmi Gönüldaş
Fehmi Gönüldaş
OHOnur Alp Halaçlı
Onur Alp Halaçlı
SKSelin Kartal
Selin Kartal
MKMehmet Ali Kılıçarslan
Mehmet Ali Kılıçarslan
This in vitro study aimed to evaluate and compare the shear bond strength (SBS) between monolithic zirconia (MZ) and different core build-up materials. Sixty cylindrical MZ specimens were fabricated and divided into three groups (n = 20) based on the type of core build-up material: nanohybrid composite resin (NHCR), glass ionomer cement (GIC), and zirconia-reinforced glass ionomer cement (zirconomer). All specimens were subjected to airborne-particle abrasion with aluminum oxide and bonded using a self-adhesive dual-cure resin cement. After 24 h of storage in distilled water at 37 °C, SBS testing was performed using a universal testing machine. Failure modes were examined under a stereomicroscope and classified as adhesive, cohesive, or mixed. The NHCR group exhibited the highest SBS values (48.32 ± 12.49 MPa), followed by the Zirkonomer group (14.19 ± 3.66 MPa), and the GIC group (10.37 ± 4.21 MPa). The SBS of NHCR was significantly higher than that of both Zirconomer and GIC (p < 0.001). Although no significant difference was found between Zirconomer and GIC, Zirconomer demonstrated higher mean bond strength. Within the limitations of this study, NHCR showed the highest bond strength to monolithic zirconia. Zirconomer performed better than conventional GIC; however, further investigations involving different surface treatments and long-term clinical conditions are recommended to enhance its bonding efficacy.

19 April 2026 in Materials
Verified
Journal Article
Open access
PDF file
ZİZeynep İrkeç
Zeynep İrkeç
AŞAyben Şentürk
Ayben Şentürk
KOKaan Orhan
Kaan Orhan
Background: Screw loosening remains a common mechanical complication in implant-supported restorations; however, the combined effect of sealing and superstructure materials on abutment screw stability warrants further investigation. Methods: This study evaluated the influence of access channel sealing material and superstructure material on abutment–implant screw stability after thermomechanical cyclic loading. Forty-eight Straumann analog–abutment assemblies restored with monolithic zirconia or resin nano-ceramic (Cerasmart) crowns were assigned to two sealing protocols: Polytetrafluoroethylene (PTFE) + composite or polyvinyl siloxane (PVS) putty (n = 12). After 750,000 off-axis cycles, reverse torque values (RTV) were analyzed using two-way analysis of variance (ANOVA) and Tukey’s HSD, with effect sizes calculated (α = 0.05). Results: A significant interaction between restorative material and sealing protocol was observed (p = 0.0170; η2 = 0.116). Superstructure material showed no significant influence on RTV (p = 0.8368), whereas sealing protocol had a significant main effect (p = 0.0499). RTVs were highest for zirconia + PVS putty (36.33 ± 4.53 Ncm) and lowest for zirconia + PTFE (29.32 ± 6.30 Ncm), while the Cerasmart groups showed intermediate values. Post hoc analysis confirmed higher RTV for zirconia + PVS compared with zirconia + PTFE (p = 0.0138). Conclusions: Access channel sealing materials showed a material-dependent influence on abutment screw stability. Silicone-based sealing improved torque maintenance in zirconia, indicating that rigid restorative materials may be more sensitive to sealing material selection. In contrast, Cerasmart showed comparable RTV regardless of sealing protocol, suggesting that resilient restorative materials may reduce the influence of sealing on preload maintenance.