This article proposes an unsupervised online spike sorter, dedicated to brain-implantable neural recording microsystems. The main (online) spike sorting phase in the proposed approach is based on the wave shape resemblance between spike classes, realized by template matching. This phase follows an offline training phase, implemented off the implant. In the training phase, the number and centroids of the clusters are automatically determined and subsequently sent to the implant to configure the on-implant online spike sorter. Comprehensively verified using two separate datasets with a wide spectrum of spike wave shapes, the proposed approach presents average classification accuracies of $\sim 85$ % (unsupervised) and $\sim 92$ % (supervised). A 64-channel spike sorter was designed using a computational core with folded architecture. To make the very large-scale integration (VLSI) implementation of this spike sorter appropriate for brain implants in terms of both power and area consumption, the computations realizing the proposed approach were significantly reduced. Designed in a standard 180-nm CMOS technology, the circuit consumes $1.74~\mu \text{W}$ /channel and per-channel area of 0.047 mm2. The circuit is capable of clustering neural spikes in real-time with a latency of as short as 1.36 ms. A prototype of the circuit was implemented and successfully tested.
2 September 2019 in Medical & Biological Engineering & Computing
In the field of Brain Machine Interface (BMI), the process of translating motor intention into a machine command is denoted as decoding. However, despite recent advancements, decoding remains a formidable challenge within BMI. The utilization of current decoding algorithms in the field of BMI often involves computational complexity and requires the use of computers. This is primarily due to the reliance on mathematical models to address the decoding issue and perform subsequent output calculations. Unfortunately, computers are not feasible for implantable BMI systems due to their size and power consumption. To address this predicament, this study proposes a pioneering approach inspired by hyperdimensional computing. This approach first involves identifying the pattern of each stimulus by considering the normal firing rate distribution of each neuron. Subsequently, the newly observed firing pattern for each input is compared with the patterns detected at each moment for each neuron. The algorithm, which shares similarities with hyperdimensional computing, identifies the most similar pattern as the final output. This approach reduces the dependence on mathematical models. The efficacy of this method is assessed through the utilization of an authentic dataset acquired from the Frontal Eye Field (FEF) of two male rhesus monkeys. The output space encompasses eight possible angles. The results demonstrate an accuracy rate of 51.5% while exhibiting significantly low computational complexity, involving a mere 2050 adder operators. Furthermore, the proposed algorithm is implemented on a field-programmable gate array (FPGA) and as an ASIC designe in a standard CMOS 180 nm technology, underscoring its suitability for real-time implantable BMI applications. The implementation required only 2.3 Kbytes of RAM, occupied an area of 2.2 mm2, and consumed 9.32 µW at a 1.8 V power supply. Consequently, the proposed solution represents an accurate, low computational complexity, hardware-friendly, and real-time approach.
16 October 2024 in International Journal of Neural Systems
Motor intention decoding is one of the most challenging issues in brain machine interface (BMI). Despite several important studies on accurate algorithms, the decoding stage is still processed on a computer, which makes the solution impractical for implantable applications due to its size and power consumption. This study aimed to provide an appropriate real-time decoding approach for implantable BMIs by proposing an agile decoding algorithm with a new input model and implementing efficient hardware. This method, unlike common ones employed firing rate as input, used a new input space based on spike train temporal information. The proposed approach was evaluated based on a real dataset recorded from frontal eye field (FEF) of two male rhesus monkeys with eight possible angles as the output space and presented a decoding accuracy of 62%. Furthermore, a hardware architecture was designed as an application-specific integrated circuit (ASIC) chip for real-time neural decoding based on the proposed algorithm. The designed chip was implemented in the standard complementary metal-oxide-semiconductor (CMOS) 180 nm technology, occupied an area of 4.15 mm2, and consumed 28.58 μW @1.8 V power supply.