In this study, a theoretical design of a simple fiberoptic gyroscope is proposed. This fiber-optic gyroscope not only realizes the full-dynamic-range of Sagnac-phase measurement, but also eliminates the excess phase affected by the elliptical birefringence of a single-mode fiber coil. Under the conditions that the fiber coil has 1100 turns and the fiber length is 242.9 m, the bias stability of this gyroscope is theoretically evaluated as 9.44°/h. In this study, we also discuss the error signal that arises from the intensity stability, as well as the polarization nonreciprocity. We generate 1000 random values to simulate the possible distribution of a bias drift, and the result shows that the drift of the Sagnac phase is less than 10 -3 °. In addition, we deduce the influence of the error signal induced by polarization nonreciprocity. The result indicates that the maximum error arises if the reciprocal phase of the SMF is φ = 2mπ (m = 0, ±1, ±2, ±3, . . .) and the optical rotation angle is θ = 45°.
Field-effect transistor (FET)-based biosensors are powerful analytical tools for detecting trace-specific biomolecules in diverse sample matrices, especially in the realms of pandemics and infectious diseases. The primary concern in applying these biosensors is their stability, a factor directly impacting the accuracy and reliability of sensing over extended durations. The risk of biosensor degradation is substantial, potentially jeopardizing the sensitivity and selectivity and leading to inaccurate readings, including the possibility of false positives or negatives. This paper delves into the documented degradation of silicon nanobelt FET (NBFET) biosensors induced by buffer solutions. The results highlight a positive correlation between immersion time and the threshold voltage of NBFET devices. Secondary ion mass spectrometry analysis demonstrates a gradual increase in sodium and potassium ion concentrations within the silicon as immersion days progress. This outcome is ascribed to the nanobelt’s exposure to the buffer solution during the biosensing period, enabling ion penetration from the buffer into the silicon. This study emphasizes the critical need to address buffer-solution-induced degradation to ensure the long-term stability and performance of FET-based biosensors in practical applications.
In this work, we dealt with the optimization of the pulley-type ring resonator using the offset of the straight input and output waveguide at the junction with the curved waveguide. We adopted the finite-difference time-domain method to simulate the structure. It was found that the coupling loss could be significantly reduced and the critical coupling could be precisely tuned. This results in the possibility of the Q-factor being higher than that of the structure without waveguide offset. In this study, the Q-factor of the ring resonator is increased from 9180 to 11,302. The corresponding enhancement is 23.1%.
Field-effect transistor (FET)-based biosensors stand as powerful analytical tools for detecting trace-specific biomolecules in diverse sample matrices, especially in the realms of pandemics and infectious diseases. The primary concern in applying these biosensors is their stability, a factor directly impacting the accuracy and reliability of sensing over extended durations. The risk of biosensor degradation is substantial, potentially jeopardizing sensitivity and selectivity and leading to inaccurate readings, including the possibility of false positives or negatives. This paper delves into the documented degradation of silicon nanobelt FET (NBFET) biosensors induced by buffer solutions. The results highlight a positive correlation between immersion time and the threshold voltage of NBFET devices. Secondary ion mass spectrometry analysis demonstrates a gradual increase in sodium and potassium ion concentrations within the silicon as immersion days progress. This outcome is ascribed to the nanobelt's exposure to the buffer solution during the biosensing period, enabling ion penetration from the buffer into the silicon. The study emphasizes the critical need to address buffer solution-induced degradation to ensure the long-term stability and performance of FET-based biosensors in practical applications.