Amine-functionalized carbon dots (A-CDs) were synthesized by one-step hydrothermal reaction of urea and citric acid. The purified CD sample exhibits a surface states dominated fluorescence emission with a quantum yield of 30%. The A-CDs demonstrate excellent sensitivity toward methamphetamine pre-precursor and precursor, and a remarkable selectivity against common drug cutting agents (diluents) such as aspirin, paracetamol, etc. The specific selectivity of CDs towards such type of drug precursor molecules is first time reported, which appears to be related to the spatial distribution of the surface functional groups. The fluorescence-based sensing mechanism is revealed by a detailed analysis on the static and dynamic fluorescence behaviour. We further demonstrated an immobilization strategy for fabricating solid-state sensors, and the retained sensitivity of the A-CDs after immobilization. The study reveals the potential of the use of a CDs as an effective sensing probe for illicit drugs, which is in demand.
This review paper updates the previous literature in relation to the continued and developing use of stable isotope ratio analysis in samples which are relevant to forensic science. Recent advances in the analysis of drug samples, explosive materials, and samples derived from human and animal samples are discussed. The paper also aims to put the use of isotope ratio mass spectrometry into a forensic context and discuss its evidential potential.
The development of novel on-line microwave techniques is described for the selective extraction of polycyclic aromatic hydrocarbons from sediment samples. Two flow systems were evaluated, in the first, samples of sediment were slurried in water and on passing through the microwave the analytes were extracted and subsequently trapped onto a C18 cartridge. Elution from the in-line C18 cartridge directly onto an analytical HPLC column was then performed. In the second study, samples were slurried in acetone and passed through the microwave cavity. The effluent was then shaken with 10 ml of hexane in order to pre-concentrate the extracted components, which were detected and quantified by GC-MS. Recoveries from the second technique on average ranged from 62 to 93% (0.28–8.15 µg). Both techniques were compared to the standard EPA method for microwave-assisted solvent extraction. The second method based on acetone, was found to give comparable recoveries to the EPA method, but offered significant improvement in the precision for replicate samples which were found to be in the range 2–7% RSD compared to 6–16% RSD for the batch technique.