Colistin is a polymixin antibiotic (polymixin E) that is produced by Bacillus colistinus bacteria. The aim of the present study was to develop and validate a method to quantify colistin levels in plasma using high performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) technique and then apply it in experimental animals (rats) to investigate the pharmacokinetic profile of colistin in this species. Polymyxin B was used as an internal standard (IS) and the quantitation was carried out using ESI + interface and employing multiple reaction monitoring (MRM) mode. A mobile phase consisting of acetonitrile:water:formic acid (30:70:0.1%; v/v/v) was employed and Zorbax eclipse plus C18 (1.8 µm, 2.1 mm i.d. x 50 mm) was the optimal column for this method and utilized at a flow rate of 0.2 mL/min. The full scan mass spectra of precursor/product ions of colistin A were at m/z 585.5 > 100.8, for colistin B at m/z 578.8 > 101 and for the IS at m/z 602.8 > 101. The lower limit of quantification (LLOQ) was 0.5 µg/mL. The method demonstrated acceptable intra-run and inter-run precision and accuracy for both colistin A and colistin B. Colistin was stable when assessed for long-term stability, freeze-thaw stability and autosampler stability. However, it was not stable when stored at room temperature. The matrix effect evaluation showed minimal or no effect. Incurred sample reanalysis findings were within acceptable ranges (<20% of the nominal concentration). The pharmacokinetic parameters of colistin were investigated in rats using the present method. The developed method for colistin demonstrates that it is rapid, sensitive, specific, accurate, precise, and reliable.
Busulfan (Bu) is an alkylating agent commonly used in preparative regimens for hematologic malignant and non-malignant patients undergoing hematopoietic stem cell transplantation (HSCT). The objective of the present study was to develop an UPLC-MS/MS method for quantification of Bu in human plasma. A total of 55 patients with hematologic malignancies (n = 34) and non- malignancies (n = 21) received myeloablative Bu therapy prior to HSCT. A tandem mass spectrometric method was developed and validated to quantify Bu levels in these patients. The method was fully validated over the concentration range of 25–2000 ng/mL (r > 0.99). The assay method demonstrated good precision and accuracy. Stability studies indicated that the drug was stable in various conditions. Incurred sample reanalysis findings were within acceptable ranges (<15% of the nominal concentration). Based on the 1stdose AUC results, one third of hematologic malignant patients and half of non-malignant patients needed dose adjustment. However, in subsequent doses (5th, 9th, and 13th), 77%, 82% and 82%, respectively, of hematologic malignant patients and 71%, 67% and 86%, respectively, of non-malignant patients achieved the target range of Bu AUC. The suitability of the developed method for routine TDM of Bu in HSCT patients was demonstrated. The study suggests that the pharmacokinetic profile of Bu varies in both groups.