Augustė Melaikaitė

Augustė Melaikaitė

Vilnius University, Faculty of Medicine, Vilnius, Vilniaus Miestas, Lithuania
orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 January 2024 in Medicina
Verified
Journal Article
Open access
PDF file
TBTomas Baltrūnas
Tomas Baltrūnas
KMKarolis Medelis
Karolis Medelis
AMAugustė Melaikaitė
Augustė Melaikaitė
ARAustėja Račytė
Austėja Račytė
GPGabija Pikturnaitė
Gabija Pikturnaitė
KRKęstutis Ručinskas
Kęstutis Ručinskas
Background and Objectives: The Walking Impairment Questionnaire (WIQ) is a short and simple tool to measure walking impairment for patients with peripheral arterial disease requiring no special equipment or trained staff. The aim of this study was to assess the validity and reliability of the culturally adapted Lithuanian WIQ version in patients with intermittent claudication. Materials and Methods: In total, 40 patients with intermittent claudication and ankle–brachial index < 0.90 participated in this study. Reliability and internal consistency of the questionnaire were assessed by the intra-class correlation coefficient (ICC) and Cronbach’s alpha (α), respectively. Validity was determined by correlations between the WIQ scores and a subjective test (Quality of Life 5 Dimension Questionnaire 3 Level Version (EQ-5D-3L)) and objective tests (6 min walk test (6MWT), treadmill test, and ankle–brachial index). Results: The test–retest reliability was assessed as excellent with an intraclass correlation coefficient of 0.90. The values of Cronbach’s alpha were 0.957 (I time) and 0.948 (II time) and indicated an excellent internal consistency. Statistically significant Spearman correlations were detected between the WIQ and walking distances on the 6MWT (rho 0.514, p < 0.001) and treadmill test (rho 0.515, p < 0.001). Higher WIQ scores were associated with longer walking distances and duration. Moderate negative and low negative correlations were found between the WIQ and EQ-5D-3L scores. Conclusions: The Lithuanian version of culturally adapted WIQ demonstrates reliability and validity for patients with intermittent claudication, supported by two different walking tests showing statistically significant moderate Spearman correlations.

23 April 2026 in Sensors
Verified
Journal Article
Open access
PDF file
VLVaidas Labunskas
Vaidas Labunskas
VDVilius Dambrauskas
Vilius Dambrauskas
AMAugustė Melaikaitė
Augustė Melaikaitė
VLVilhelmas Konstantinas Landsbergis
Vilhelmas Konstantinas Landsbergis
RKRadvilė Kadytė
Radvilė Kadytė
TBTomas Baltrūnas
Tomas Baltrūnas
This prospective, cross-sectional study evaluated reaction time (RT) variations across different sensory stimuli to investigate the efficacy of haptic feedback (HF) in reducing response latency for telesurgical applications. Three healthy-volunteer age cohorts (18–25, 35–45, and 55–65 years) were tested using visual, auditory, superficial, and deep sensations, alongside a multimodal stimulus combining visual and superficial inputs to simulate HF. The findings revealed that combined visual and superficial stimulation yielded a mean RT of 227 ± 27 ms, outperforming visual-only stimulation by 40 ms (95% CI: 32–48 ms) and superficial-only stimulation by 26 ms (95% CI: 20–33 ms) (p = 0.001). While this performance boost was consistent across all age groups, the 55–65 age cohort demonstrated the most pronounced reduction in RT when the combined stimuli were used. These results suggest that integrating tactile sensations with visual cues significantly mitigates latency compared to unimodal inputs, underscoring the potential of haptic feedback to enhance operator performance and safety in latency-sensitive environments like remote surgery.