Ascorbic acid (AA) is a water-soluble vitamin which shows no fluorescence. However, in reaction with iron(III), AA is oxidised to dehydroascorbic acid and iron(III) is reduced to iron(II) which forms a complex with 2,4,6-tripyridyl-S-triazine (TPTZ) in buffered medium. The relative fluorescence intensity of the resulting Fe(TPTZ)22+ complex can be measured at excitation and emission wavelengths of 393 and 790 nm, respectively. Based on this data, a new indirect spectrofluorimetric method for the determination of AA in pharmaceutical samples was proposed. Influence of the reaction conditions, such as acidity of acetic buffer, concentration of TPTZ and iron(III), reaction time and instrumental parameters were investigated in detail. The linear range was from 5.4 × 10−4 to 5.4 × 10−6 mol·L−1 (R = 0.9971). The LOD was 7.7 × 10−7 mol·L−1 and LOQ was 2.3 × 10−4 mol·L−1. Fourteen pharmaceutical samples containing various amounts of AA were analysed. Influences of potential interfering substances were also examined. Analysis of commercial pharmaceutical formulations showed good correlation with the nominal values given by the manufacturers and with the results obtained by a titration method. The proposed method can be applied in routine quality control in the pharmaceutical industry due to its sensitivity, simplicity, selectivity and low cost.
New sequential injection analysis (SIA) methods with optical sensing for the determination of N-acetyl-L-cysteine ethyl ester (NACET) have been developed and optimized. NACET is a potential drug and antioxidant with advantageous pharmacokinetics. The methods involve the reduction of Cu(II) in its complexes with neocuproine (NCN), bicinchoninic acid (BCA), and bathocuproine disulfonic acid (BCS) to the corresponding chromophoric Cu(I) complexes by the analyte. The absorbance of the Cu(I) complexes with NCN, BCA, and BCS was measured at their maximum absorbance wavelengths of 458, 562, and 483 nm, respectively. The sensing manifold parameters and experimental conditions were optimized for each of the Cu(II) complexes used. Under optimal conditions, the corresponding linear calibration ranges, limits of detection, and sampling rates were 8.0 × 10−6–2.0 × 10−4 mol L−1, 5.5 × 10−6 mol L−1, and 60 h−1 for NCN; 6.0 × 10−6–1.0 × 10−4 mol L−1, 5.2 × 10−6 mol L−1, and 60 h−1 for BCA; and 4.0 × 10−6–1.0 × 10−4 mol L−1, 2.6 × 10−6 mol L−1, and 78 h−1 for BCS. The Cu(II)-BCS complex was found to be best performing in terms of sensitivity and sampling rate. Usual excipients in pharmaceutical preparations did not interfere with NACET analysis.
A new flow-injection spectrophotometric method for the determination of glutathione (GSH), penicillamine (PEN) and tiopronin (mercaptopropionyl glycine, MPG) in pharmaceutical formulations is reported. The method is based on the...
A sequential injection analysis method for the determination of glutathione (GSH) in pharmaceuticals has been developed. It is based on the reduction of the Cu(II)-neocuproine complex by GSH and the formation of an orange-yellow colored Cu(I)-neocuproine complex with maximum absorbance at 458 nm. Under optimal conditions the method is characterized by a linear calibration range of 6.0 × 10−7–8.0 × 10−5 mol L−1 (Amax = 3270 CGSH − 0.0010; R2 = 0.9983), limit of detection of 2.0 × 10−7 mol L−1, limit of quantification of 6.7 × 10−7 mol L−1, repeatability (expressed as relative standard deviation) of 3.8%, and sampling rate of 60 h−1. The newly developed method has been successfully applied to the determination of GSH in pharmaceutical samples with no statistically significant difference between the results obtained and those produced by the standard Pharmacopoeia method.
Leaching of the extractant from polymer inclusion membranes (PIMs) into the feed and receiving aqueous solutions shortens their life. Therefore, when a particular PIM extractant has been selected, it is important to choose a base polymer that will minimize to the greatest extent extractant leaching compared to other base polymers, thus providing the best stability of the PIM. However, comparisons of the stability of PIMs composed of the same extractant and different base polymers is usually conducted by multiple cycles of extraction and back-extraction steps, which are time-consuming and labor-intensive. An alternative approach based on thermal analysis (thermogravimetric analysis (TGA) and differential thermal analysis (DTA)) was developed and applied to PIMs containing 40 wt.% Aliquat 336, one of the most frequently used PIM extractants, and the three most frequently used PIM base polymers, i.e., poly(vinyl chloride) (PVC), cellulose triacetate (CTA), and poly(vinylidene fluoride-co-hexafluoropropylene) (PVDF-HFP). The temperatures and enthalpies associated with Aliquat 336 release were compared, with PVDF-HFP exhibiting the highest values, indicating the strongest interaction between the extractant and the polymer matrix and, thus, the highest stability. The PVC-based PIM was predicted to be the most prone to extractant leaching among the PIMs studied. This stability ranking was confirmed theoretically by quantum chemistry (DFT) calculations, which provided molecular-level insights into the likely interaction sites between Aliquat 336 and the polymer chains. An experimental validation of the above leaching order was also provided by PIM leaching experiments in aqueous 0.1 M and 0.05 M NaCl solutions, where membrane mass losses over a 24 h period were determined. The results of the current study demonstrated thermal analysis to be a fast and viable approach in comparing the stability of PIMs with the same extractant but different base polymers.
N-acetyl-L-cysteine (NAC), a sulfhydryl-containing compound, is mainly used as a mucolytic and as an antidote for acetaminophen overdose. Flow injection and sequential injection systems were designed and optimized with the aim of providing precise, a...