Machine learning (ML), artificial neural networks (ANNs), and deep learning (DL) are all topics that fall under the heading of artificial intelligence (AI) and have gained popularity in recent years. ML involves the application of algorithms to automate decision-making processes using models that have not been manually programmed but have been trained on data. ANNs that are a part of ML aim to simulate the structure and function of the human brain. DL, on the other hand, uses multiple layers of interconnected neurons. This enables the processing and analysis of large and complex databases. In medicine, these techniques are being introduced to improve the speed and efficiency of disease diagnosis and treatment. Each of the AI techniques presented in the paper is supported with an example of a possible medical application. Given the rapid development of technology, the use of AI in medicine shows promising results in the context of patient care. It is particularly important to keep a close eye on this issue and conduct further research in order to fully explore the potential of ML, ANNs, and DL, and bring further applications into clinical use in the future.
Objectives: The purpose of this study is to evaluate the performance of our deep learning algorithm in calculating cardiothoracic ratio (CTR) and thus in the assessment of cardiomegaly or pericardial effusion occurrences on chest radiography (CXR). Methods: From a database of 8000 CXRs, 13 folders with a comparable number of images were created. Then, 1020 images were chosen randomly, in proportion to the number of images in each folder. Afterward, CTR was calculated using RadiAnt Digital Imaging and Communications in Medicine (DICOM) Viewer software (2023.1). Next, heart and lung anatomical areas were marked in 3D Slicer. From these data, we trained an AI model which segmented heart and lung anatomy and determined the CTR value. Results: Our model achieved an Intersection over Union metric of 88.28% for the augmented training subset and 83.06% for the validation subset. F1-score for subsets were accordingly 90.22% and 90.67%. In the comparative analysis of artificial intelligence (AI) vs. humans, significantly lower transverse thoracic diameter (TTD) (p < 0.001), transverse cardiac diameter (TCD) (p < 0.001), and CTR (p < 0.001) values obtained using the neural network were observed. Conclusions: Results confirm that there is a significant correlation between the measurements made by human observers and the neural network. After validation in clinical conditions, our method may be used as a screening test or advisory tool when a specialist is not available, especially on Intensive Care Units (ICUs) or Emergency Departments (ERs) where time plays a key role.
Cerebral vascular angiography, or digital subtraction angiography (DSA), is essential for diagnosing neurological conditions but poses radiation risks. This study aims to analyze the impact of examination parameters and patient characteristics on the radiation dose received during DSA to optimize safety and minimize exposure. A retrospective analysis of 251 DSA procedures using the GE Innova IGS 630 dual-plane instrument was conducted. Data on dose area product (DAP) and air kerma (KERMA), along with patient and examination details, were collected. Statistical analyses, including Mann–Whitney, Kruskal–Wallis, and Spearman rank correlation tests, assessed the relationships between variables and radiation dose outcomes. Significant correlations were found between the sides examined (left, right, or both) and DAP (p < 0.0001) and KERMA (p < 0.0001) values, with bilateral studies showing the highest values. The post hoc Dunn tests showed that the ‘L + P’ group significantly differs from both the right group (p < 0.0001 and the left group (p < 0.0001). There is no significant difference between the ‘P’ group and the ‘L’ group (p-value = 0.53). These results suggest that the right and left (both) group have unique KERMA mGy values compared to the other two groups. A strong correlation (rS = 0.87) existed between DAP and KERMA. The number of projections significantly impacted radiation dose (rS = 0.61). Tube parameters (kV and mA) and skull size had low correlations with DAP and KERMA. Optimizing imaging protocols and individualizing parameters can significantly enhance patient safety and diagnostic efficacy while also reducing occupational exposure for medical staff.
As the number of smartphones increases, so does the number of medical apps. Medical mobile applications are widely used in many medical fields by both patients and doctors. However, there are still few approved mobile applications that can be used in the diagnostic-therapeutic process and radiological apps are affected as well. We conducted our research by classifying radiological applications from the Google Play® store into appropriate categories, according to our own qualification system developed by researchers for the purposes of this study. In addition, we also evaluated apps from the App Store®. The radiology application rating system we created has not been previously used in other articles. Out of 228 applications from the Google Play store, only 6 of them were classified as “A” category with the highest standard. Apps from the App Store (157) were not categorized due to the lack of download counts, which was necessary in our app-rating system. The vast majority of applications are for educational purposes and are not used in clinical practice. This is due to the need of obtaining special permits and certificates from relevant institutions in order to use them in medical practice. We recommend applications from the Google Play store that have been classified in the “A” category, evaluating them as the most valuable. App Store apps data is described and presented in the form of diagrams and tables.
Investigating the correlation between patient dimensions (Body Mass Index (BMI), weight, height) and radiation dose, the study also assesses the impact of the isocenter on dosage and X-ray tube. This retrospective study analyzed 258 consecutive three-phase liver CT exams (135 women, 123 men) performed on a Siemens SOMATOM Definition Edge scanner between January 3 and December 15, 2023. BMI, weight, height, maximum abdominal width (from topograms), and vertical isocenter status were extracted using the Dose&Care system and Horos software. BMI strongly correlated with total DLP in abdomen-plus-pelvis scans (r = 0.70) and moderately in abdomen-only scans (r = 0.54). Liver-phase DLP correlations were weaker (r = 0.44 and r = 0.28, respectively). Abdominal width showed similar associations with total DLP (r = 0.67 and r = 0.64) and liver-phase DLP (r = 0.41 and 0.37). Vertical mis-centering did not significantly affect total DLP (p = 0.174 and p = 0.705) or tube load. Patient size—not minor deviations from the isocenter—is the principal driver of radiation dose in multiphase liver CT. Automated, size-adapted protocols and restriction of scan range to clinically essential regions can preserve image quality while minimizing unnecessary radiation in routine practice.