Joost J A De Jong

Dr. Joost J A De Jong


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2021 in Radiology
Verified
Journal Article
Closed access
LVLaura W. M. Vergoossen
Laura W. M. Vergoossen
JJJacobus F A Jansen
Jacobus F A Jansen
TSThomas T. van Sloten
Thomas T. van Sloten
CSCoen D. A. Stehouwer
Coen D. A. Stehouwer
NSNicolaas Schaper
Nicolaas Schaper
WBWalter H. Backes
Walter H. Backes
White matter hyperintensity volume, local efficiency, and information processing speed scores are interrelated, and local network alterations as response to white matter abnormality explain detrime... Background Lesions of cerebral small vessel disease, such as white matter hyperintensities (WMHs) in individuals with cardiometabolic risk factors, interfere with the trajectories of the white matt...

1 July 2014 in Bone
Verified
Journal Article
Closed access
JJJoost J A De Jong
Joost J A De Jong
PWPaul C. Willems
Paul C. Willems
CAChris Arts
Chris Arts
SBSandrine G.P. Bours
Sandrine G.P. Bours
PBPeter R.G. Brink
Peter R.G. Brink
PBPeter Van Den Berg
Peter Van Den Berg

1 October 2024 in Hypertension
Verified
Journal Article
Open access
MKMarieke van Den Kerkhof
Marieke van Den Kerkhof
JJJoost J A De Jong
Joost J A De Jong
PVPaulien Voorter
Paulien Voorter
APAlida Annechien Postma
Alida Annechien Postma
AKAbraham A. Kroon
Abraham A. Kroon
WBWalter H. Backes
Walter H. Backes
BACKGROUND: Blood-brain barrier (BBB) integrity is presumed to be impaired in hypertension, resulting from cerebral endothelial dysfunction. Hypertension precedes various cerebrovascular diseases, such as cerebral small vessel disease, and is a risk factor for developing neurodegenerative diseases for which BBB disruption is a preceding pathophysiological process. In this cross-sectional study, we investigated the relation between hypertension, current blood pressure, and BBB leakage in human subjects. METHODS: BBB leakage was determined in 22 patients with hypertension and 19 age- and sex-matched normotensive controls (median age [range], 65 [45–80] years; 19 men) using a sparsely time-sampled contrast-enhanced 7T magnetic resonance imaging protocol. Structural cerebral small vessel disease markers were visually rated. Multivariable regression analyses, adjusted for age, sex, cardiovascular risk factors, and cerebral small vessel disease markers, were performed to determine the relation between hypertension status, systolic and diastolic blood pressure, mean arterial pressure, drug treatment, and BBB leakage. RESULTS: Both hypertensive and normotensive participants showed mild scores of cerebral small vessel disease. BBB leakage did not differ between hypertensive and normotensive participants; however, it was significantly higher for systolic blood pressure, diastolic blood pressure, and mean arterial pressure in the cortex, and diastolic blood pressure and mean arterial pressure in the gray matter. Effectively treated patients showed less BBB leakage than those with current hypertension. CONCLUSIONS: BBB integrity in the total and cortical gray matter decreases with increasing blood pressure but is not related to hypertension status. These findings show that BBB disruption already occurs with increasing blood pressure, before the presence of overt cerebral tissue damage. Additionally, our results suggest that effective antihypertensive medication has a protective effect on the BBB. REGISTRATION: URL: https://trialsearch.who.int/ ; Unique identifier: NL7537.

16 December 2015 in Journal of Bone and Mineral Research
Verified
Journal Article
Open access
PDF file
JJJoost J A De Jong
Joost J A De Jong
FHFrans L Heyer
Frans L Heyer
CAChris Arts
Chris Arts
MPMartijn Poeze
Martijn Poeze
AKAndrás P Keszei
András P Keszei
PBPeter Van Den Berg
Peter Van Den Berg
Fracture healing is characterized by an intense increase in modeling and remodeling of bone, which allows removal of the cast after a stable distal radius fracture within 3 to 5 weeks. However, at that time, bone strength has not recovered yet. We studied the changes in bone mineral density (BMD), microarchitecture, and bone stiffness after a distal radius fracture during a 2‐year follow‐up in comparison to the contralateral side and the association between the 2‐year stiffness and baseline BMD, microarchitecture, and early changes in these parameters. The fractured side of 14 postmenopausal women (mean age 64 ± 8 years) with a conservatively treated distal radius fracture was scanned by high‐resolution peripheral quantitative computed tomography (HRpQCT) at 1 to 2, 3 to 4, 6 to 8, and 12 weeks and 2 years postfracture. The same region contralaterally was scanned as well at the 2‐year visit. BMD, microarchitecture, and stiffness parameters were determined and the fracture side was compared with the contralateral side using a linear mixed‐effect model. Spearman's correlation was used to correlate the 2‐year bone stiffness with baseline BMD, microarchitecture, and early 3‐month changes in these parameters. Two years postfracture, cortical and trabecular thickness and torsional and bending stiffness were significantly higher at the fractured side compared with the nonfractured side (21%, 55%, 31%, and 29%, respectively, p < 0.05), whereas BMD was similar. Two‐year torsional and bending stiffness correlated significantly with baseline BMD and cortical perimeter (|rho| ≥ 0.63, p < 0.016) but not with early changes in bone parameters. Using HRpQCT, this study illustrates that fracture healing is not completed by the time the cast is removed. We showed that from 6 weeks to 2 years postfracture, large changes occur in BMD, microarchitecture, and biomechanical parameters at the fractured side, which were fully recovered after 2 years in comparison to the nonfractured contralateral side. Interestingly, higher 2‐year torsional and bending stiffness were associated with lower BMD and higher cortical perimeter at baseline. © 2015 American Society for Bone and Mineral Research.

18 March 2014 in Journal of Bone and Mineral Research
Verified
Journal Article
Open access
PDF file
UMUrsina Meyer
Ursina Meyer
JJJoost J A De Jong
Joost J A De Jong
SBSandrine Gp Bours
Sandrine Gp Bours
AKAndrás P Keszei
András P Keszei
CAChris Arts
Chris Arts
PWPaul C Willems
Paul C Willems
Fracture healing is an active process with early changes in bone and inflammation. We performed an exploratory study evaluating the association between early changes in densitometric, structural, biomechanical, and biochemical bone parameters during the first weeks of fracture healing and wrist‐specific pain and disability at 12 weeks in postmenopausal women with a conservatively treated distal radius fracture. Eighteen patients (aged 64 ± 8 years) were evaluated at 1 to 2 and 3 to 4 weeks postfracture, using high‐resolution peripheral quantitative computed tomography (HR‐pQCT), micro‐finite element analysis, serum procollagen type‐I N‐terminal propeptide (P1NP), carboxy‐terminal telopeptide of type I collagen (ICTP), and high‐sensitive C‐reactive protein (hsCRP). After 12 weeks, patients rated their pain and disability using Patient Rated Wrist Evaluation (PRWE) questionnaire. Additionally, Quick Disability of the Arm Shoulder and Hand (QuickDASH) questionnaire and active wrist range of motion was evaluated. Linear regression models were used to study the relationship between changes in bone parameters and in hsCRP from visit 1 to 2 and PRWE score after 12 weeks. A lower PRWE outcome, indicating better outcome, was significantly related to an early increase in trabecular bone mineral density (BMD) (β −0.96 [95% CI −1.75 to −0.16], R2 = 0.37), in torsional stiffness (−0.14 [−0.28 to −0.004], R2 = 0.31), and to an early decrease in trabecular separation (209 [15 to 402], R2 = 0.33) and in ICTP (12.1 [0.0 to 24.1], R2 = 0.34). Similar results were found for QuickDASH. Higher total dorsal and palmar flexion range of motion was significantly related to early increase in hsCRP (9.62 [3.90 to 15.34], R2 = 0.52). This exploratory study indicates that the assessment of early changes in trabecular BMD, trabecular separation, calculated torsional stiffness, bone resorption marker ICTP, and hsCRP after a distal radius fracture provides valuable information regarding the 12‐week clinical outcome in terms of pain, disability, and range of motion and validates its use in studies on the process of early fracture healing. © 2014 American Society for Bone and Mineral Research.

27 February 2017 in BMC Medical Imaging
Verified
Journal Article
Open access
PDF file
JJJoost J A De Jong
Joost J A De Jong
ALArno Lataster
Arno Lataster
BRBert van Rietbergen
Bert van Rietbergen
CAChris Arts
Chris Arts
PGPiet P. Geusens
Piet P. Geusens
PWPaul Willems
Paul Willems
Carbon-fiber-reinforced poly-ether-ether-ketone (CFR-PEEK) has superior radiolucency compared to other orthopedic implant materials, e.g. titanium or stainless steel, thus allowing metal-artifact-free postoperative monitoring by computed tomography (CT). Recently, high-resolution peripheral quantitative CT (HRpQCT) proved to be a promising technique to monitor the recovery of volumetric bone mineral density (vBMD), micro-architecture and biomechanical parameters in stable conservatively treated distal radius fractures. When using HRpQCT to monitor unstable distal radius fractures that require volar distal radius plating for fixation, radiolucent CFR-PEEK plates may be a better alternative to currently used titanium plates to allow for reliable assessment. In this pilot study, we assessed the effect of a volar distal radius plate made from CFR-PEEK on bone parameters obtained from HRpQCT in comparison to two titanium plates. Plates were instrumented in separate cadaveric human fore-arms (n = 3). After instrumentation and after removal of the plates duplicate HRpQCT scans were made of the region covered by the plate. HRpQCT images were visually checked for artifacts. vBMD, micro-architectural and biomechanical parameters were calculated, and compared between the uninstrumented and instrumented radii. No visible image artifacts were observed in the CFR-PEEK plate instrumented radius, and errors in bone parameters ranged from −3.2 to 2.6%. In the radii instrumented with the titanium plates, severe image artifacts were observed and errors in bone parameters ranged between −30.2 and 67.0%. We recommend using CFR-PEEK plates in longitudinal in vivo studies that monitor the healing process of unstable distal radius fractures treated operatively by plating or bone graft ingrowth.