Pelvic organ prolapse (POP) is a major health issue with a lifetime risk of undergoing at least one surgical intervention estimated at close to 10%. In the 1990s, the risk of reoperation after primary standard vaginal procedure was estimated to be as high as 30% to 50%. In order to reduce the risk of relapse, gynecological surgeons started to use mesh implants in pelvic organ reconstructive surgery with the emergence of new complications. Recent studies have nevertheless shown that the risk of POP recurrence requiring reoperation is lower than previously estimated, being closer to 10% rather than 30%. The development of mesh surgery – actively promoted by the marketing industry – was tremendous during the past decade, and preceded any studies supporting its benefit for our patients. Randomized trials comparing the use of mesh to native tissue repair in POP surgery have now shown better anatomical but similar functional outcomes, and meshes are associated with more complications, in particular for transvaginal mesh implants. POP is not a life-threatening condition, but a functional problem that impairs quality of life for women. The old adage “primum non nocere” is particularly appropriate when dealing with this condition which requires no treatment when asymptomatic. It is currently admitted that a certain degree of POP is physiological with aging when situated above the landmark of the hymen. Treatment should be individualized and the use of mesh needs to be selective and appropriate. Mesh implants are probably an important tool in pelvic reconstructive surgery, but the ideal implant has yet to be found. The indications for its use still require caution and discernment. This review explores the reasons behind the introduction of mesh augmentation in POP surgery, and aims to clarify the risks, benefits, and the recognized indications for its use.
1 December 2006 in European Journal of Surgical Oncology
OBJECTIVE: To estimate the incidence and identify the risk factors for pelvic organ prolapse repair after hysterectomy. METHODS: We conducted a case-control study. We identified 6,214 women who underwent hysterectomy in our gynecology department from 1982 to 2002. Cases (n=114) were women who required pelvic organ prolapse surgery after hysterectomy from January 1982 through December 2005. Controls (n=236) were women randomly selected from the same cohort who did not require pelvic organ surgery during the same period. We performed a univariable and a multivariable analysis among 104 cases and 190 controls to identify the variables associated with prolapse repair after hysterectomy. RESULTS: The incidence of pelvic organ prolapse that required surgical correction after hysterectomy was 1.3 per 1,000 women-years. The risk of prolapse repair was 4.7 times higher in women whose initial hysterectomy was indicated by prolapse and 8.0 times higher if preoperative prolapse grade 2 or more was present. Risk factors included preoperative prolapse grade 2 or more (adjusted odds ratio [OR] 12.6, 95% confidence interval [CI] 4.6–34.7), previous pelvic organ prolapse or urinary incontinence surgery (adjusted OR 7.9, 95% CI 1.3–48.2), history of vaginal delivery (adjusted OR 5.0, 95% CI 1.3–19.7), and sexual activity (adjusted OR 6.2, 95% CI 2.7–14.5). Vaginal hysterectomy was not a risk factor when preoperative prolapse was taken into account (adjusted OR 0.7, 95% CI 0.4–1.1). CONCLUSION: Preoperative pelvic organ prolapse and other factors related to pelvic floor weakness were significantly associated with subsequent pelvic floor repair after hysterectomy. Vaginal hysterectomy was not a risk factor. LEVEL OF EVIDENCE: II
5 September 2008 in International Urogynecology Journal
Backround: The transobturator tape procedure (TOT) is an effective surgical treatment of female stress urinary incontinence. However data concerning safety are rare, follow-up is often less than two years, and complications are probably underreported. The aim of this study was to describe early and late complications associated with TOT procedures and identify risk factors for erosions. Methods: It was a 27 months follow-up of a cohort of 233 women who underwent TOT with three different types of slings (Aris®, Obtape®, TVT-O®). Follow-up information was available for 225 (96.6%) women. Results: There were few per operative complications. Forty-eight women (21.3%) reported late complications including de novo or worsening of preexisting urgencies (10.2%), perineal pain (2.2%), de novo dyspareunia (9%), and vaginal erosion (7.6%). The risk of erosion significantly differed between the three types of slings and was 4%, 17% and 0% for Aris®, Obtape® and TVT-O® respectively (P = 0.001). The overall proportion of women satisfied by the procedure was 72.1%. The percentage of women satisfied was significantly lower in women who experienced erosion (29.4%) compared to women who did not (78.4%) (RR 0.14, 95% CI 0.05-0.38, P < 0.001). Conclusion: Late post operative complications are relatively frequent after TOT and can impair patient's satisfaction. Women should be informed of these potential complications preoperatively and require careful follow-up after the procedure. Choice of the safest sling material is crucial as it is a risk factor for erosion.
1 January 2003 in American Journal of Obstetrics and Gynecology