Dulce Gonzalez-Beltran

Dulce Gonzalez-Beltran


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 November 2023 in Atmosphere
Verified
Journal Article
Open access
PDF file
SSSumit Sankhyan
Sumit Sankhyan
NCNicholas Clements
Nicholas Clements
AHAllison Heckman
Allison Heckman
AHAniya K. Hollo
Aniya K. Hollo
DGDulce Gonzalez-Beltran
Dulce Gonzalez-Beltran
SMShelly Miller
Shelly Miller
The large-scale deployment of Do-it-yourself (DIY) air cleaners, especially in communities that historically bear the brunt of air pollution exposure-related injustices, provides communities a cost-effective option to reduce personal indoor exposure to particulate matter. In this study, we developed nine air cleaner prototypes, altering filter depth and the number and type of filters, and compared their PM2.5 removal effectiveness and maintenance-related parameters prior to deployment in North Denver, Colorado homes. Prototypes containing multiple high efficiency particulate air filters with a minimum reporting value of 13 (MERV13) had higher clean air delivery rates (CADR, >300 m3 h−1) compared to prototypes using a single filter (100–200 m3 h−1), but single-filter designs had comparable values of CADR normalized by initial and annual operating costs. Based on performance, cost, build time, and feedback from the community regarding concerns related to volatile organic compound exposure, the selected prototype (P9) used a combination of an activated carbon filter and single MERV13 filter with a 10.16 cm (4-inch) depth. Following this assessment, 120 of the selected air cleaner prototypes were built and deployed in homes around the communities in North Denver for two separate cohorts; feedback regarding their usage over the course of the deployment showed that in addition to the increased noise levels perceived by the participants, factors such as cold air flow from the air cleaner impacting the thermal comfort and aesthetics of the design reduced their usage time in homes. Future designs of DIY air cleaners could incorporate this feedback to help design improved features such as quieter air cleaners and real-time pollutant monitoring feedback to prompt users to keep them operational at all times of the day.

10 June 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
SSSumit Sankhyan
Sumit Sankhyan
AHAniya K Hollo
Aniya K Hollo
DGDulce Gonzalez-Beltran
Dulce Gonzalez-Beltran
NCNicholas Clements
Nicholas Clements
SMShelly Miller
Shelly Miller
Carbon monoxide (CO) is a colorless, odorless gas emitted from carbon fuel combustion. In this study we monitored indoor carbon monoxide (CO) levels for 120 homes over three seasons in the North Denver metropolitan region as part of an environmental justice initiative to quantify health and social well-being impacts from a major freeway construction upgrade nearby. Urban outdoor CO levels are typically very low (less than 1 ppm in Denver) due to air pollution control strategies and technologies implemented over the past several decades. However, people can still be exposed to higher than outdoor levels of CO in their homes due to the operation of indoor appliances that use carbon fuels such as natural gas. Our data show that ~10% of the homes had consistent daily average levels of CO above 3.5 ppm and 24-57% of the homes showed peaks greater than 9 ppm. While much higher levels can result in CO poisoning and fatalities, these lower levels of CO have been associated with adverse health impacts, especially pregnant women, and sensitive populations. Our results highlight the need for increasing awareness regarding CO exposures in homes with gas appliances and motivate the transition from non-electrified homes toward electrification.