Ella Markalunas

Ms. Ella Markalunas

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 June 2024 in Genes
Verified
Journal Article
Open access
PDF file
EMElla Markalunas
Ella Markalunas
DADavid Harrison Arnold
David Harrison Arnold
AFAvery T. Funkhouser
Avery T. Funkhouser
Julie C. MartinJulie C. Martin
Julie C. Martin
MSMichael Shtutman
Michael Shtutman
Anna BlendaAnna Blenda
Anna Blenda
Galectins are innate immune system regulators associated with disease progression in cancer. This paper aims to investigate the correlation between mutated cancer-critical genes and galectin levels in breast cancer patients to determine whether galectins and genetic profiles can be used as biomarkers for disease and potential therapy targets. Prisma Health Cancer Institute’s Biorepository provided seventy-one breast cancer samples, including all four stages spanning the major molecular subtypes and histologies. Hotspot mutation statuses of cancer-critical genes were determined using multiplex PCR in tumor samples from the same patients by Precision Genetics and the University of South Carolina Functional Genomics Core Facility. The galectin-1, -3, and -9 levels in patients’ sera were analyzed using Enzyme-linked Immunosorbent Assay (ELISA). An analysis was performed using JMP software to compare mean and median serum galectin levels between samples with and without specific cancer-critical genes, including pooled t-test, Wilcoxon Rank Sum Test, ANOVA, and Steel Dwass Test (α=0.05). Our analysis indicates that KIT mutations correlate with elevated serum levels of galectin-9 in patients with breast cancer. In patients with Luminal A subtype, FLT3 mutation correlates with lower serum galectin-1 and -9 levels and TP53 mutations correlate with higher serum galectin-3 levels. Patients with invasive ductal carcinoma had significantly higher serum galectin-3 levels than patients with ductal carcinoma in situ. Patients with both TP53 and PIK3CA mutations exhibit elevated serum galectin-3 levels, while patients with one or neither mutation show no significant difference in serum galectin-3 levels. In addition, metastatic breast cancer samples were more likely to have a KIT or PIK3CA mutation compared to primary breast cancer samples. The relationship between genetic mutations and galectin levels has the potential to identify appropriate candidates for combined therapy, targeting genetic mutations and galectins. Further understanding of the effect of genetic mutations and galectin levels on cancer progression and metastasis could aid in the search for biomarkers for breast cancer diagnosis, disease progression, and prognosis.

10 May 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
EMElla Markalunas
Ella Markalunas
DADavid Harrison Arnold
David Harrison Arnold
AFAvery T. Funkhouser
Avery T. Funkhouser
Julie C. MartinJulie C. Martin
Julie C. Martin
MSMichael Shtutman
Michael Shtutman
Anna BlendaAnna Blenda
Anna Blenda
Background: Galectins are innate immune system regulators, associated with disease progression in cancer. This paper aims to investigate the correlation between mutated cancer-critical genes and galectin levels in breast cancer patients to determine whether galectins and genetic profiles can be used as biomarkers for disease and potential therapy targets. Materials and Methodology: Prisma Health Cancer Institute’s Biorepository provided seventy-one breast cancer patient samples, including all four stages as well as major molecular subtypes and histologies of breast cancer. Hotspot mutation statuses of cancer-critical genes were determined using multiplex PCR in tumor samples from the same patients by Precision Genetics and the University of South Carolina Functional Genomics Core Facility. The galectin levels of patients’ sera were analyzed using enzyme-linked immunosorbent assay (ELISA) to measure the concentrations of galectins-1, -3, and -9. Analysis was performed using JMP software to compare mean and median serum galectin levels between samples with and without specific cancer-critical genes including pooled t-test, Wilcoxon test, ANOVA, Tukey’s range test, and Steel Dwass Method (α=0.05). Results: Our analysis indicates that KIT mutations correlate with elevated serum levels of galectin-1 and -9 in patients with breast cancer. In patients with Luminal A subtype, FLT3 mutation correlates with lower serum galectin-1 and -9 levels and TP53 mutations correlate with higher serum galectin-3 levels. Patients with invasive ductal carcinoma had significantly higher serum galectin-3 levels than patients with ductal carcinoma in situ. Patients with both TP53 and PIK3CA mutations exhibit elevated serum galectin-3 levels, while patients with one or neither mutation show no significant difference in serum galectin-3 levels. In addition, metastatic breast cancer samples were more likely to have KIT or PIK3CA mutation compared to primary breast cancer samples. Conclusion: The relationship between genetic mutations and galectin levels has the potential to identify appropriate candidates for combined therapy, targeting genetic mutations and galectins. Further understanding of the effect of genetic mutations and galectin levels on cancer progression and metastasis could aid in the search for biomarkers for breast cancer diagnosis, disease progression, and prognosis.

5 August 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
EMElla Markalunas
Ella Markalunas
SHShannon Harold
Shannon Harold
DADavid Harrison Arnold
David Harrison Arnold
Julie C. MartinJulie C. Martin
Julie C. Martin
WEWilliam Jeffery Edenfield
William Jeffery Edenfield
Anna BlendaAnna Blenda
Anna Blenda
Background: Galectin-3 (Gal-3) levels have been indicated as a promising diagnostic, prognostic, and therapeutic target in breast cancer patients. Serum galectin-3 levels are traditionally measured using manual Enzyme-Linked Immunosorbent Assay (ELISA), but recent automated methods, such as ProteinSimple’s SimplePlex assay run on an Ella instrument, have shown promising evidence of being faster and less error-prone than manual methods. This paper aims to assess whether there are differences in serum galectin-3 measurements between automated and manual ELISA methods. Methods: Galectin-3 serum levels were analyzed from one hundred and five breast cancer samples using both manual ELISA and the Ella instrument. JMP was used to perform paired t-tests and regression analyses. Results: The Ella instrument resulted in significantly lower coefficients of variation (CV), confirming that it is more precise and reliable than manual ELISA methods. There was a moderate correlation between ELISA and Ella measurements (r=0.54), but a paired t-test revealed that automated ELISA using Ella resulted in significantly lower galectin-3 levels compared to manual ELISA (p< 0.0001). Regression analysis showed a significant increase in the difference between Ella and manual ELISA measurements as serum galectin-3 levels increase (p< 0.0001). Conclusions: While the Ella instrument is a fast and reliable tool, the discrepancies between manual ELISA and the Ella instrument in quantifying galectin-3 levels are important to address prior to widespread use.

1 October 2025 in Cancers
Verified
Journal Article
Open access
PDF file
EMElla Markalunas
Ella Markalunas
SHShannon E. Harold
Shannon E. Harold
DADavid Harrison Arnold
David Harrison Arnold
Julie C. MartinJulie C. Martin
Julie C. Martin
WEWilliam Jeffery Edenfield
William Jeffery Edenfield
Anna BlendaAnna Blenda
Anna Blenda
Background: Circulating galectin-3 (Gal-3) levels have been indicated as a promising diagnostic, prognostic, and therapeutic target in breast cancer patients. Specifically, serum galectin-3 levels are traditionally measured using manual Enzyme-Linked Immunosorbent Assay (ELISA), but recent automated methods, such as Simple Plex assay by ProteinSimple™ run on an Ella instrument, have shown promising evidence of being more efficient and less error-prone than manual methods. This paper aims to assess whether there are differences in serum galectin-3 measurements between manual and automated ELISA methods. Methods: Serum galectin-3 levels were initially analyzed from one hundred and fifteen breast cancer samples using both manual ELISA and the Ella instrument. Following coefficient of variation (CV) and outlier analysis, ninety-five samples were analyzed further with JMP statistical software to perform Shapiro-Wilk, Spearman’s correlation, Wilcoxon signed-rank, and regression analyses. Results: The Ella instrument resulted in significantly lower CV values, confirming that it is more precise and reliable than manual ELISA methods. There was a moderate correlation between ELISA and Ella measurements (r = 0.49, p < 0.0001), but a Wilcoxon signed-rank test revealed that serum gaelectin-3 measurements obtained with the Ella instrument were significantly lower compared to those obtained with manual ELISA, with a mean difference of −5.19 ng/mL (p < 0.0001). Regression analysis showed a significant increase in the difference between manual ELISA and Ella measurements as serum galectin-3 levels increase (p < 0.0001). This difference in measurements between manual and automated ELISA techniques remained consistent when analyses were performed within each breast cancer stage, immunophenotype, and histology. Conclusions: While the Ella instrument is a fast and reliable tool, the discrepancies between manual ELISA and the Ella instrument in quantifying serum galectin-3 levels are important to consider prior to widespread use.