Chien-Hao Liu

Prof. Chien-Hao Liu

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 June 2023 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
Abhinav SharmaAbhinav Sharma
Abhinav Sharma
WAWejdan S. AlGhamdi
Wejdan S. AlGhamdi
HFHendrik Faber
Hendrik Faber
YLYen-Hung Lin
Yen-Hung Lin
CLChien-Hao Liu
Chien-Hao Liu
TAThomas D. Anthopoulos
Thomas D. Anthopoulos

21 June 2021 in IEEE Journal of Solid-State Circuits
Verified
Journal Article
Closed access
SWSung-Hao Wang
Sung-Hao Wang
YHYu-Kai Huang
Yu-Kai Huang
CCChing-Yuan Chen
Ching-Yuan Chen
LTLi-Yang Tang
Li-Yang Tang
YTYen-Fu Tu
Yen-Fu Tu
CWChung-Yu Wu
Chung-Yu Wu
A CMOS bone-guided cochlear implant (BGCI) microsystem is proposed and verified. In the implanted System on Chip (SoC) of the proposed BGCI, the evoked compound action potential (ECAP) acquisition and electrode–tissue impedance measurement (EAEIM) circuit is integrated to measure both ECAP and electrode–tissue impedance for clinical diagnoses. Both positive-/negative-voltage charge pumps and monopolar biphasic constant-current stimulation (CCS) stimulator are designed on-chip to realize monopolar biphasic CCS or double-electrode multiple stimulations with a maximum stimulation current of 1.2 mA and a step of 10 $\mu \text{A}$ . With the double-electrode multiple stimulations, the electric field can be shifted and localized under the stimulating electrode to stimulate the auditory nerves. The wireless bilateral data telemetry circuits with a full-wave active rectifier and the pulsed load-shift keying (PLSK) modulators/demodulators are designed for power and data transmission. In vivo animal tests on guinea pigs have shown that the Wave III of electrically evoked auditory brainstem responses (EABRs) can be evoked successfully by electrical stimulation. Moreover, the decreasing latency gradient of evoked Wave III has been measured under the double-electrode multiple stimulations where the location of peak electric field can be shifted to the stimulating electrode in the apical site to stimulate the auditory nerves. Thus, the desired frequency resolution and spatial specificity of stimulation can be achieved. Both electrical measurement and in vivo animal tests have verified that the proposed BGCI microsystem is a feasible solution to eliminate the symptoms for patients with high-frequency hearing loss.

14 February 2013 in Journal of Applied Physics
Verified
Journal Article
Closed access
PDF file
CLChien-Hao Liu
Chien-Hao Liu
NBNader Behdad
Nader Behdad
In this paper, we experimentally investigate the phenomenon of electromagnetic wave tunneling through ϵ-negative (ENG) metamaterial layers surrounded by double-positive layers. Initial experiments are conducted by using a rectangular waveguide, which operates below its cutoff frequency to emulate an ENG layer. This ENG layer is then sandwiched by two dielectric substrates with relatively high dielectric constants and it is shown that the entire setup acts as a classical microwave filter with a second-order bandpass response. The power handling capability of this filter is examined experimentally using a high-power magnetron source with a frequency of 9.382 GHz, a pulse duration of 1 μs, and a peak power of 25 kW. Based on the results of this experiment, two methods for improving the power handling capability of these multi-layer structures are proposed. In particular, it is demonstrated that emulating the ENG layers with thin perforated metallic sheets with sub-wavelength holes significantly enhances their peak power handling capability. A prototype of such a device is designed, fabricated, and experimentally characterized and it is demonstrated that it can handle extremely high peak power levels. The results presented in this work are expected to be useful in designing microwave filters and frequency selective surfaces that can handle extremely high peak power levels.

5 December 2022 in Applied Physics Letters
Verified
Journal Article
Open access
PDF file
WAWejdan S. AlGhamdi
Wejdan S. AlGhamdi
AFAiman Fakieh
Aiman Fakieh
HFHendrik Faber
Hendrik Faber
YLYen-Hung Lin
Yen-Hung Lin
WLWei-Zhi Lin
Wei-Zhi Lin
TAThomas D. Anthopoulos
Thomas D. Anthopoulos
Combining low-dimensional layers of dissimilar metal oxide materials to form a heterojunction structure offers a potent strategy to improve the performance and stability of thin-film transistors (TFTs). Here, we study the impact of channel layer thicknesses on the operating characteristics of In2O3/ZnO heterojunction TFTs prepared via sputtering. The conduction band offset present at the In2O3/ZnO heterointerface affects the device's operating characteristics, as is the thickness of the individual oxide layers. The latter is investigated using a variety of experimental and computational modeling techniques. An average field-effect mobility (μFE) of >50 cm2 V−1 s−1, accompanied by a low threshold voltage and a high on/off ratio (∼108), is achieved using an optimal channel configuration. The high μFE in these TFTs is found to correlate with the presence of a quasi-two-dimensional electron gas at the In2O3/ZnO interface. This work provides important insight into the operating principles of heterojunction metal oxide TFTs, which can aid further developments.

25 February 2019 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
XQXin-Hong Qian
Xin-Hong Qian
YLYu-Chi Lee
Yu-Chi Lee
JCJia-Heng Chang
Jia-Heng Chang
SLShih-Ting Lin
Shih-Ting Lin
SLShang-Hsuan Li
Shang-Hsuan Li
YLYung-Jen Lin
Yung-Jen Lin
Objective: To develop and verify a CMOS bone-guided cochlear implant (BGCI) microsystem with electrodes placed on the bone surface of the cochlea and the outside of round window for treating high-frequency hearing loss. Methods: The BGCI microsystem consists of an external unit and an implanted unit. The external system-on-chip (SOC) is designed to process acoustic signals through an acquisition circuit and an acoustic DSP processor to generate stimulation patterns and commands that are transmitted to the implanted unit through a 13.56 MHz wireless power and bidirectional data telemetry. In the wireless power te-lemetry, a voltage doubler/tripler (2X/3X) active rectifier is used to enhance the power conversion efficiency and generate 2 V and 3 V output voltages. In the wireless data telemetry, phase-locked loop (PLL) based binary phase-shift keying (BPSK) and load-shift keying (LSK) modulators/demodulators are adopted for the down-link and uplink data through high-Q coils, respectively. The im-planted chip with 4-channel high-voltage-tolerant stimulator gen-erates biphasic stimulation currents up to 800 μA. Results: Electri-cal tests on the fabricated BGCI microsystem has been performed to verify the chip functions. The in-vivo animal tests in guinea pigs have shown the evoked third wave (Wave eIII) of electrically evoked auditory brainstem response (EABR) waveforms. It is ver-ified that auditory nerves can be successfully stimulated and acoustic hearing can be partially preserved. Conclusion and Significance: Different from traditional cochlear implants, the pro-posed BGCI microsystem is less invasive, preserves partially acoustic hearing, and provides an effective alternative to treating high-frequency hearing loss.

19 March 2019 in The International Journal of Advanced Manufacturing Technology
Verified
Journal Article
Closed access
PDF file
YYYung-Chen Yao
Yung-Chen Yao
YCYu-Hsuan Chen
Yu-Hsuan Chen
CLChien-Hao Liu
Chien-Hao Liu
WSWen-Pin Shih
Wen-Pin Shih