Siyu Yao

Prof. Dr. Siyu Yao


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 January 2024 in Biomedicines
Verified
Journal Article
Open access
PDF file
HBHaona Bao
Haona Bao
Kevin HackshawKevin Hackshaw
Kevin Hackshaw
SCSilvia de Lamo Castellvi
Silvia de Lamo Castellvi
YWYalan Wu
Yalan Wu
Celeste GonzalezCeleste Gonzalez
Celeste Gonzalez
Luis Rodriguez-SaonaLuis Rodriguez-Saona
Luis Rodriguez-Saona
Fibromyalgia (FM) is a chronic muscle pain disorder that shares several clinical features with other related rheumatologic disorders. This study investigates the feasibility of using surface-enhanced Raman spectroscopy (SERS) with gold nanoparticles (AuNPs) as a fingerprinting approach to diagnose FM and other rheumatic diseases such as rheumatoid arthritis (RA), systemic lupus erythematosus (SLE), osteoarthritis (OA), and chronic low back pain (CLBP). Blood samples were obtained on protein saver cards from FM (n = 83), non-FM (n = 54), and healthy (NC, n = 9) subjects. A semi-permeable membrane filtration method was used to obtain low-molecular-weight fraction (LMF) serum of the blood samples. SERS measurement conditions were standardized to enhance the LMF signal. An OPLS-DA algorithm created using the spectral region 750 to 1720 cm−1 enabled the classification of the spectra into their corresponding FM and non-FM classes (Rcv > 0.99) with 100% accuracy, sensitivity, and specificity. The OPLS-DA regression plot indicated that spectral regions associated with amino acids were responsible for discrimination patterns and can be potentially used as spectral biomarkers to differentiate FM and other rheumatic diseases. This exploratory work suggests that the AuNP SERS method in combination with OPLS-DA analysis has great potential for the label-free diagnosis of FM.

2 January 2024 in Foods
Verified
Journal Article
Open access
PDF file
SYSiyu Yao
Siyu Yao
Gonzalo Miyagusuku-CruzadoGonzalo Miyagusuku-Cruzado
Gonzalo Miyagusuku-Cruzado
MWMegan West
Megan West
VNVictor Nwosu
Victor Nwosu
EDEric Dowd
Eric Dowd
Luis Rodriguez-SaonaLuis Rodriguez-Saona
Luis Rodriguez-Saona
A nondestructive and rapid classification approach was developed for identifying aflatoxin-contaminated single peanut kernels using field-portable vibrational spectroscopy instruments (FT-IR and Raman). Single peanut kernels were either spiked with an aflatoxin solution (30 ppb–400 ppb) or hexane (control), and their spectra were collected via Raman and FT-IR. An uHPLC-MS/MS approach was used to verify the spiking accuracy via determining actual aflatoxin content on the surface of randomly selected peanut samples. Supervised classification using soft independent modeling of class analogies (SIMCA) showed better discrimination between aflatoxin-contaminated (30 ppb–400 ppb) and control peanuts with FT-IR compared with Raman, predicting the external validation samples with 100% accuracy. The accuracy, sensitivity, and specificity of SIMCA models generated with the portable FT-IR device outperformed the methods in other destructive studies reported in the literature, using a variety of vibrational spectroscopy benchtop systems. The discriminating power analysis showed that the bands corresponded to the C=C stretching vibrations of the ring structures of aflatoxins were most significant in explaining the variance in the model, which were also reported for Aspergillus-infected brown rice samples. Field-deployable vibrational spectroscopy devices can enable in situ identification of aflatoxin-contaminated peanuts to assure regulatory compliance as well as cost savings in the production of peanut products.

15 January 2024 in Molecules
Verified
Journal Article
Open access
PDF file
SNShreya Madhav Nuguri
Shreya Madhav Nuguri
Kevin HackshawKevin Hackshaw
Kevin Hackshaw
SCSilvia de Lamo Castellvi
Silvia de Lamo Castellvi
HBHaona Bao
Haona Bao
SYSiyu Yao
Siyu Yao
Luis Rodriguez-SaonaLuis Rodriguez-Saona
Luis Rodriguez-Saona
The diagnostic criteria for fibromyalgia (FM) have relied heavily on subjective reports of experienced symptoms coupled with examination-based evidence of diffuse tenderness due to the lack of reliable biomarkers. Rheumatic disorders that are common causes of chronic pain such as rheumatoid arthritis, systemic lupus erythematosus, osteoarthritis, and chronic low back pain are frequently found to be comorbid with FM. As a result, this can make the diagnosis of FM more challenging. We aim to develop a reliable classification algorithm using unique spectral profiles of portable FT-MIR that can be used as a real-time point-of-care device for the screening of FM. A novel volumetric absorptive microsampling (VAMS) technique ensured sample volume accuracies and minimized the variation introduced due to hematocrit-based bias. Blood samples from 337 subjects with different disorders (179 FM, 158 non-FM) collected with VAMS were analyzed. A semi-permeable membrane filtration approach was used to extract the blood samples, and spectral data were collected using a portable FT-MIR spectrometer. The OPLS-DA algorithm enabled the classification of the spectra into their corresponding classes with 84% accuracy, 83% sensitivity, and 85% specificity. The OPLS-DA regression plot indicated that spectral regions associated with amide bands and amino acids were responsible for discrimination patterns and can be potentially used as spectral biomarkers to differentiate FM and other rheumatic diseases.

12 December 2025 in Food Chemistry
Verified
Journal Article
Closed access
SYSiyu Yao
Siyu Yao
TYTong Yu
Tong Yu
ARAlessandra Fantina Victorio Ramos
Alessandra Fantina Victorio Ramos
ZZZhongkun Zhang
Zhongkun Zhang
LRLuis Rodriguez-Saona
Luis Rodriguez-Saona

9 September 2025 in Food Chemistry: X
Verified
Journal Article
Open access
SYSiyu Yao
Siyu Yao
TYTong Yu
Tong Yu
ARAlessandra Fantina Victorio Ramos
Alessandra Fantina Victorio Ramos
ZZZhongkun Zhang
Zhongkun Zhang
ZRZulipikaer Rouzi
Zulipikaer Rouzi
Luis Rodriguez-SaonaLuis Rodriguez-Saona
Luis Rodriguez-Saona
Recent advances in vibrational spectroscopy combined with machine learning are enabling smart and in-situ detection of mycotoxins in complex food matrices. Infrared and spontaneous Raman spectroscopy detect molecular vibrations or compositional changes in host matrices, capturing direct or indirect mycotoxin fingerprints, while surface-enhanced Raman spectroscopy (SERs) amplifies characteristic mycotoxins molecular vibrations via plasmonic nanostructures, enabling ultra-sensitive detection. Machine learning further enhances analysis by extracting subtle and unique mycotoxin spectral features from information-rich spectra, suppressing noise, and enabling robust predictions across heterogeneous samples. This review critically examines recent sensing strategies, model development, application performance, non-destructive screening, and potential application challenges, highlighting strengths and limitations relative to conventional methods. Innovations in portable, miniaturized spectrometers integrated with cloud computation are also discussed, supporting scalable, rapid, and on-site mycotoxin monitoring. By integrating state-of-art vibrational fingerprints with computational analysis, these approaches provide a pathway toward sensitive, smart, and field-deployable mycotoxin detection in food.

21 June 2024
Verified
Book Chapter
Closed access
PDF file
Luis Rodriguez-SaonaLuis Rodriguez-Saona
Luis Rodriguez-Saona
SYSiyu Yao
Siyu Yao
SNShreya Madhav Nuguri
Shreya Madhav Nuguri