Kazuki NAKAJIMA

Prof. Dr. Kazuki NAKAJIMA


Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2019 in Advanced Biomedical Engineering
Verified
Journal Article
Open access
PDF file
KFKoya Fujita
Koya Fujita
YKYoshio Kanayama
Yoshio Kanayama
JKJuhyon Kim
Juhyon Kim
KNKazuki NAKAJIMA
Kazuki NAKAJIMA
Japan's largest platform for academic e-journals: J-STAGE is a full text database for reviewed academic papers published by Japanese societies

1 January 2014 in Advanced Biomedical Engineering
Verified
Journal Article
Closed access
KNKazuki NAKAJIMA
Kazuki NAKAJIMA
YHYutaro Hayase
Yutaro Hayase
KTKeiko Tonami
Keiko Tonami
GYGenki Yamaguchi
Genki Yamaguchi
JKJuhyon Kim
Juhyon Kim
TFToshiro Fujimoto
Toshiro Fujimoto

1 January 2020 in Advanced Biomedical Engineering
Verified
Journal Article
Open access
PDF file
SKShujiro Konno
Shujiro Konno
JKJuhyon Kim
Juhyon Kim
KNKazuki NAKAJIMA
Kazuki NAKAJIMA
The number of people requiring care in Japan has increased with the increase in number of people aged 65 or more. Thus, the production of disposable diapers for the elderly is also increasing. Two types of diapers; pad-type and tape-type, are generally used in combination in nursing homes. Diaper change is a burden for both the caregiver and the care receiver. To reduce the number of diaper changes, this study aimed to develops electrodes as a capacitive sensor attached to the outer surface of the tape-type diaper. The capacitive sensor evaluates the absorption volume of the pad-type diaper, and consists of electrodes and a converter circuit that converts the capacitance of electrodes into an output voltage. The study used a waist-type torso mannequin wearing a pad-type diaper on the inside and a tape-type diaper on the outside. The inside of the torso was filled with saline, and the weight of the torso including the saline was 8.9 kg in total. The electrodes were made of copper tape fixed to an insulating film, and the copper tape was 500-mm long and 25-mm wide with a 20-mm interelectrode gap. The electrodes were attached to the outside of the tape-type diaper and connected to the circuit. Experiment was conducted with the torso placed in supine and 30º lateral positions. Tap water (100 mL) was introduced via a silicone tube between the pad-type diaper and the torso hip surface at a flow rate of 7.8 mL/s, which is the average urinary flow rate for the elderly. This procedure was repeated six times. The experiment was repeated three times. The output voltage increased linearly with increasing volume of water absorbed by the pad-type diaper, in both torso positions. Therefore, the absorption volume was quantitatively evaluated, and the results suggested that the resolution was at least 100 mL when using this sensor.

1 January 2022 in Advanced Biomedical Engineering
Verified
Journal Article
Open access
PDF file
KSKeisuke Shichitani
Keisuke Shichitani
STSota Tanaka
Sota Tanaka
YFYuki Fujio
Yuki Fujio
SYShintaro Yamamoto
Shintaro Yamamoto
JKJyuhyon Kim
Jyuhyon Kim
KNKazuki NAKAJIMA
Kazuki NAKAJIMA
The production of disposable diapers is rising due to an increase in number of elderly people who require nursing care. When providing diaper care, it is difficult to know remotely the time of urination and amount of urine absorbed by a diaper. Hence, a remote sensor system that automatically records the time and amount of wine in a diaper is being developed. in this study, a digital capacitive sensor system was developed to estimate the amount of diaper absorption. Preliminary and phantom experiments were conducted to investigate the basic performance of the developed system. We also measured the amount of urination of two subjects using the developed system. A phantom, a waist-type torso mannequin filled with saline solution, and two male subjects wore pad-type diaper on the inside and tape-type diaper on the outside. Electrodes were attached to the outer surface of the tape-type diaper to measure the change in capacitance caused by urination. In the preliminary experiment, the developed system measured capacitors with known capacitance within 5.47% error. In the phantom experiment, the change in capacitance decreased as the amount of pseudo-wine absorbed by the pad-type diaper increased. Moreover, the results of human subjects urinating five times were consistent with the results of the preliminary experiment. Therefore, remote and quantitative evaluation of the urine absorption volume was possible using the developed digital system.

1 January 2020 in Advanced Biomedical Engineering
Verified
Journal Article
Open access
PDF file
ANArata Nakagawa
Arata Nakagawa
JKJuhyon Kim
Juhyon Kim
KNKazuki NAKAJIMA
Kazuki NAKAJIMA
Many sensors have been developed to measure physiological information in the toilet for healthcare management and disease prevention. These sensors require personal identification to classify toilet users, assuming that several people use the same toilet. We aimed to provide biometrics based on cardiovascular physiological information obtained from a toilet seat. An electrocardiogram was measured by the toilet seat, and personal identification was performed, as in the previous study. In this study, we developed a ballistocardiographic (BCG) monitoring system using two vibration sensors installed beneath a toilet seat. We recorded 70 BCGs from seven healthy males during their urination. Peaks H, I, J, K, and L of the BCGs were clearly obtained. Twenty-six features such as amplitude and interval were calculated from the BCG peaks. Personal identification was performed using the Mahalanobis distance, and the accuracy of identification and equal error rate (EER) were calculated. The average identification accuracy was found to be 92.2%, and the average EER was found to be 34.1%. Although the EER was not sufficiently low, the average accuracy suggested that the proposed method using a toilet seat could provide adequate biometrics for application in the healthcare system.

1 January 2024 in Advanced Biomedical Engineering
Verified
Journal Article
Open access
PDF file
RSRyuta Sakamoto
Ryuta Sakamoto
TFTetsuya Fujita
Tetsuya Fujita
KNKazuki NAKAJIMA
Kazuki NAKAJIMA
A scale-type uroflowmeter designed specifically for male standing urination has been developed. While several uroflowmeters exist, most require the voided urine to come into contact with a uroflowmeter container or similar device. These devices and containers may become contaminated with urine, necessitating cleaning, and potentially serving as a breeding ground for infection. To address these issues, we developed a scale-type uroflowmeter. One example of a typical disease causing lower urinary tract symptoms is benign prostatic hyperplasia. Our uroflowmeter is designed to automatically measure the decrease in weight during standing urination. A basic study using water demonstrated an excellent correlation between the volume of water poured and the measured weight, with errors within 10 mL. Furthermore, a feasibility study involving five young and six older subjects showed good agreement in voided volume (VV) and maximum urinary flow rate (Qmax) between the novel device and a medical uroflowmeter. The average VV error rate was 5.30 ± 4.60%, and Qmax error rate was 15.74 ± 16.91%. The uroflowmeter for standing urination developed in this study allowed measurement of VV and Qmax with the same accuracy as the medical uroflowmeter. This system has the potential to be utilized as a noncontact uroflowmeter, offering a more hygienic and convenient solution for measuring urinary flow.