Yukichi Horiguchi

Dr. Yukichi Horiguchi


Research Focus & Metrics

Academic Career Length

36Years (1991-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 March 2013 in The Analyst
Verified
Journal Article
Closed access
PDF file
TLThangavel Lakshmipriya
Thangavel Lakshmipriya
MFMakoto Fujimaki
Makoto Fujimaki
SGSubash C. B. Gopinath
Subash C. B. Gopinath
KAKoichi Awazu
Koichi Awazu
YHYukichi Horiguchi
Yukichi Horiguchi
YNYukio Nagasaki
Yukio Nagasaki
An evanescent-field-coupled waveguide-mode (EFC-WM) sensor utilizes monolithic SiO2/Si/SiO2 sensing plates having a multilayered structure and is used to evaluate a blocking agent comprising poly(ethylene glycol)-based block copolymers. Factor IX (FIX) protein was detected using its aptamer, viz. FIX was immobilized on a glutaraldehyde-modified silica surface, and then treated with a biotinylated aptamer. The quantitative analysis of FIX was carried out using streptavidin-conjugated gold nanoparticles (SA-GNPs). The blocking polymer, poly(ethylene glycol)-b-poly(acrylic acid) (PEG-b-PAAc), was found to mask unreacted amine and glutaraldehyde (Glu) moieties on the SiO2 surface, and it completely prevented the non-specific binding of SA-GNPs. By exploiting the strong blocking effect of PEG-b-PAAc, we achieved high ligand–analyte interaction sensitivity (sensitive down to 100 pM). To improve the sensitivity further, we also used pentaethylenehexamine-terminated PEG (N6-PEG) on GNPs. The improvement in sensitivity was found to be 1000-fold (to 100 fM), which was substantiated by the observation of higher numbers of GNPs on the sensing surface in the results of the scanning electron microscopic examination. Based on the competition assay of free biotin premixed with SA-GNPs, it was concluded that some active biotin-binding sites on the streptavidin were blocked by N6-PEG, which improved the binding ability to the biotinylated sensing surface. An optimum number of binding sites on the SA-GNPs might improve their binding affinity. The strategy shown with dual polymers, viz. blocking of the sensor chip surface and coating of SA-GNPs, is recommended for developing sensors with higher sensitivity and reliability. Selective binding of the aptamer to a very small amount of FIX in the mixed sample containing FXIa and FVIIa, or albumin, makes this the optimal strategy for detecting a FIX deficiency in human blood samples.

19 May 2014 in The Analyst
Verified
Journal Article
Closed access
PDF file
TLThangavel Lakshmipriya
Thangavel Lakshmipriya
YHYukichi Horiguchi
Yukichi Horiguchi
YNYukio Nagasaki
Yukio Nagasaki
In order to detect an extremely low amount of human coagulation factor IX (FIX), poly(ethylene glycol) (PEG)/aptamer co-immobilized surface was constructed using original PEG–polyamine surface modification agents on surface plasmon resonance (SPR) sensor chip. Initially, a gold (Au) sensor chip of SPR was modified using poly(ethylene glycol)-b-poly[2-(N,N-dimethylamino)ethyl methacrylate] (PEG-b-PAMA) followed by treatment with SH-dT20 and was duplexed with anti-FIX aptamer extended using A24. Furthermore, the co-immobilization of pentaethylenehexamine-terminated poly(ethylene glycol) (N6-PEG) on the sensing surface completely quenched bio-fouling. On this dual tethered PEG-surface, we determined that the dissociation constant for FIX–aptamer interaction was 37 ± 10 pM, and the sensitivity of detection could reach up to 800 fM on using aptamer–FIX–antibody sandwich pattern detected by gold nanoparticle-conjugated anti-mouse antibody. We could detect FIX in the presence of abundant albumin. Furthermore, to mimic the actual detection of FIX in clinical samples, we demonstrated our experimental results with human blood plasma instead of FIX. Higher-sensitivity was attained because of dual polymers immobilized on Au surface, and this can emerge as a common strategy for any aptamer–protein interactions. The selective binding of aptamer in human blood plasma described here indicates the suitability of the present strategy for detection in clinically relevant samples.

30 August 2008 in Langmuir
Verified
Journal Article
Closed access
YHYukichi Horiguchi
Yukichi Horiguchi
KHKanako Honda
Kanako Honda
YKYuichi Kato
Yuichi Kato
NNNaotoshi Nakashima
Naotoshi Nakashima
YNYasuro Niidome
Yasuro Niidome

13 April 2017 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
WHWenfeng Hai
Wenfeng Hai
Tatsuro GodaTatsuro Goda
Tatsuro Goda
HTHiroaki Takeuchi
Hiroaki Takeuchi
SYShoji Yamaoka
Shoji Yamaoka
YHYukichi Horiguchi
Yukichi Horiguchi
YMYuji Miyahara
Yuji Miyahara

1 May 2018 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
WHWenfeng Hai
Wenfeng Hai
TGTatsuro Goda
Tatsuro Goda
HTHiroaki Takeuchi
Hiroaki Takeuchi
SYShoji Yamaoka
Shoji Yamaoka
YHYukichi Horiguchi
Yukichi Horiguchi
YMYuji Miyahara
Yuji Miyahara

1 October 2016 in Biomaterials
Verified
Journal Article
Closed access
ZGZhenyu Gao
Zhenyu Gao
YHYukichi Horiguchi
Yukichi Horiguchi
KNKei Nakai
Kei Nakai
AMAkira Matsumura
Akira Matsumura
MSMinoru Suzuki
Minoru Suzuki
YNYukio Nagasaki
Yukio Nagasaki