Due to the growth in the application of antibacterial nanomaterials (NMs), there is an increased potential for ingestion by humans. Evidence shows that NMs can induce dysbiosis in the gut microbiota in vivo. However, in vitro investigation of the antibacterial activity of NMs on gut-relevant, commensal bacteria has been neglected, with studies predominantly assessing NM toxicity against pathogenic bacteria. The current study investigates the antibacterial activity of copper oxide (CuO) NMs to Escherichia coli K12, Enterococcus faecalis, and Lactobacillus casei using a combination of approaches and evaluates the importance of reactive oxygen species (ROS) production as a mechanism of toxicity. The impact of CuO NMs (100, 200, and 300 μg/mL) on the growth and viability of bacterial strains was assessed via plate counts, optical density (OD) measurements, well and disc diffusion assays, and live/dead fluorescent imaging. CuO NMs reduced the viability of all bacteria in a concentration-dependent manner in all assays except the diffusion assays. The most sensitive methods were OD measurements and plate counts. The sensitivity of bacterial strains varied depending on the method, but overall, the results suggest that E. coli K12 is the most sensitive to CuO NM toxicity. The production of ROS by all bacterial strains was observed via DCFH-DA fluorescent imaging following exposure to CuO NMs (300 μg/mL). Overall, the data suggests that CuO NMs have antibacterial activity against gut-relevant bacteria, with evidence that NM-mediated ROS production may contribute to reductions in bacterial viability. Our findings suggest that the use of a combination of assays provides a robust assessment of the antibacterial properties of ingested NMs, and in particular, it is recommended that plate counts and OD measurements be prioritised in the future when screening the antibacterial properties of NMs.
Efficient isolation and ultrasensitive detection of cancer cell‐derived extracellular vesicles (EVs), which carry molecular fingerprints of their parent cells, can enable precise early‐stage cancer diagnostics and prognostics. In this study, we developed a label‐free impedimetric biosensor using electroactive 3D porous graphene foam (3D‐PGF) electrodes to detect CD81 protein and MCF‐7 cells‐derived EVs in human serum. 1‐pyrenebutyric acid N‐hydroxysuccinimide ester (PYB‐NHS) was non‐covalently attached to the 3D‐PGF via π–π interactions without compromising structural integrity or electrocatalytic performance. Sensor selectivity was achieved by immobilizing anti‐CD81 antibodies onto the modified electrode, followed by quenching and blocking with ethanolamine and bovine serum albumin. MCF‐7 cells‐derived EVs were isolated by ultracentrifugation and characterized using nanoparticle tracking analysis and immunoaffinity plate‐based assay. Capture and detection of CD81‐ and MCF‐7‐derived EVs were evaluated using electrochemical impedance spectroscopy with a ferro/ferri redox mediator. The sensor demonstrated exceptional sensitivity, with limits of detection of 0.048 fg/mL for CD81 protein and ∼24 EVs/mL for MCF‐7 EVs. Performance was benchmarked against 2D graphene electrodes, highlighting structural and electrochemical advantages. The binder‐free 3D‐PGF combined with non‐covalent functionalization establishes a robust platform for selective, label‐free, and ultrasensitive detection of cancer‐cell‐derived EVs in human serum samples.