Background: The outbreak of novel coronavirus pneumonia (NCP) caused by 2019-nCoV spread rapidly, and elucidating the diagnostic accuracy of different respiratory specimens is crucial for the control and treatment of this disease. Methods: Respiratory samples including nasal swabs, throat swabs, sputum and bronchoalveolar lavage fluid (BALF) were collected from Guangdong CDC confirmed NCP patients, and viral RNAs were detected using a CFDA approved detection kit. Results were analyzed in combination with sample collection date and clinical information. Findings: Except for BALF, the sputum possessed the highest positive rate (74.4%∼88.9%), followed by nasal swabs (53.6%∼73.3%) for both severe and mild cases during the first 14 days after illness onset (d.a.o). For samples collected ≥ 15 d.a.o, sputum and nasal swabs still possessed a high positive rate ranging from 42.9%∼61.1%. The positive rate of throat swabs collected ≥ 8 d.a.o was low, especially in samples from mild cases. Viral RNAs could be detected in all the lower respiratory tract of severe cases, but not the mild cases. CT scan of cases 02, 07 and 13 showed typical viral pneumonia with ground-glass opacity, while no viral RNAs were detected in first three or all the upper respiratory samples. Interpretation: Sputum is most accurate for laboratory diagnosis of NCP, followed by nasal swabs. Detection of viral RNAs in BLAF is necessary for diagnosis and monitoring of viruses in severe cases. CT scan could serve as an important make up for the diagnosis of NCP. Funding: National Science and Technology Major Project, Sanming Project of Medicine and China Postdoctoral Science Foundation.
The outbreak of Coronavirus Disease 2019 (COVID-19) caused by the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) emerged in Wuhan, December 2019, and continuously poses a serious threat to public health. Our previous study has shown that cytokine storm occurred during SARS-CoV-2 infection, while the detailed role of cytokines in the disease severity and progression remained unclear due to the limited case number. In this study, we examined 48 cytokines in the plasma samples from 53 COVID-19 cases, among whom 34 were severe cases, and the others moderate. Results showed that 14 cytokines were significantly elevated upon admission in COVID-19 cases. Moreover, IP-10, MCP-3, and IL-1ra were significantly higher in severe cases, and highly associated with the PaO 2 /FaO 2 and Murray score. Furthermore, the three cytokines were independent predictors for the progression of COVID-19, and the combination of IP-10, MCP-3 and IL-1ra showed the biggest area under the curve (AUC) of the receiver-operating characteristics (ROC) calculations. Serial detection of IP-10, MCP-3 and IL-1ra in 14 severe cases showed that the continuous high levels of these cytokines were associated with disease deterioration and fatal outcome. In conclusion, we report biomarkers that closely associated with disease severity and outcome of COVID-19. These findings add to our understanding of the immunopathologic mechanisms of SARS-CoV-2 infection, providing novel therapeutic targets and strategy.
Dual‐mode readout platforms with colorimetric and electrochemiluminescence (ECL) signal enhancement are proposed for the ultrasensitive and flexible detection of the monkeypox virus (MPXV) in different scenes. A new nanotag, Ru@U6‐Ru/Pt NPs is constructed for dual‐mode platforms by integrating double‐layered ECL luminophores and the nanozyme using Zr‐MOF (UiO‐66‐NH2) as the carrier, which not only generates enhanced ECL and colorimetric signals but also provide greater stability than that of commonly used nanotags. Dual‐mode platforms are used within 15 min from the “sample in” to the “result out” steps, without nucleic acid amplification. The colorimetric mode allows the screening of MPXV with the visual limit of detection (vLOD) of 0.1 pM (6 × 108 copies µL−1) and the ECL mode supports quantitative detection of MPXV with an LOD as low as 10 aM (6 copies·µL−1), resulting in a broad sensing range of 60 to 3 × 1011 copies·µL−1 (10 orders of magnitude). Validation is conducted using 50 clinical samples, which is 100% concordant to those of quantitative polymerase chain reaction (qPCR), indicating that Ru@U6‐Ru/Pt NPs‐based dual‐mode sensing platforms showed great promise as rapid, sensitive, and accurate tools for diagnosis of the nucleic acid of MPXV and other infectious pathogens.
4 January 2023 in Frontiers in Cellular Neuroscience
Coronavirus disease 2019 (COVID-19) was reported to be associated with severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) infection, and patients present mostly with respiratory symptoms. There have been an increasing number of reports on oral manifestations, and some of these signs are informative in terms of identifying SARS-CoV-2 infection. The goal of present study was to review and synthesize the clinical characteristics and underlying mechanisms of COVID-19 oral manifestations, as well as to evaluate the factors influencing SARS-CoV-2 infectivity, in order to conduct further in-depth investigations and help clinicians diagnose COVID-19 patients exhibiting oral symptoms.
The ongoing SARS-CoV-2 outbreak has killed over twenty-one thousand and sickened over four hundred thousand people worldwide, posing a great challenge to global public health. A sensitive and accurate diagnosis method will substantially help to control disease expansion. Here, we developed a chemiluminescence-immunoassay method based on the recombinant nucleocapsid antigen and the magnetic beads for diagnosis of SARS-CoV-2 infections and surveillance of antibody changing pattern. Serums from 29 healthy individuals, 51 tuberculosis patients, and 79 SARS-CoV-2 confirmed patients were employed to evaluate the performance of this approach. Compared to the IgM testing, the IgG testing was more reliable in which it identified 65 SARS-CoV-2 infections from the 79 confirmed patients and only two false-positive cases from the 80 control group with a sensitivity and specificity reaching 82.28% and 97.5%, respectively. However, only a slight difference (not statistically significant) in the detected cases of SARS-CoV-2 infections was observed between the IgM and IgG testing manner in patients at a different time of onset of disease. A performance comparison between an ELISA kit using the same nucleocapsid antigen and our chemiluminescence method was undertaken. The same false-positive cases were seen in both methods from the paired control group, while ELISA kit can only detect half of the SARS-CoV-2 infections from paired SARS-CoV-2 confirmed patients group than that of the chemiluminescence method, indicating a higher performance for the chemiluminescence-immunoassay approach. Together, our studies provide a useful and valuable serological testing tool for the diagnosis of SARS-CoV-2 infections in the community.
Early monitoring and warning arrangements are effective ways to distinguish infectious agents and control the spread of epidemic diseases. Current testing technologies, which cannot achieve rapid detection in the field, have a risk of slowing down the response time to the disease. In addition, there is still no epidemic surveillance system, implementing prevention and control measures is slow and inefficient. Motivated by these clinical needs, a sample‐to‐answer genetic diagnosis platform based on light‐controlled capillary modified with a photocleavable linker is first developed, which could perform nucleic acid separation and release by light irradiation in less than 30 seconds. Then, on site polymerase chain reaction was performed in a handheld closed‐loop convective system. Test reports are available within 20 min. Because this method is portable, rapid, and easy to operate, it has great potential for point‐of‐care testing. Additionally, through multiple device networking, a real‐time artificial intelligence monitoring system for pathogens was developed on a cloud server. Through data reception, analysis, and visualization, the system can send early warning signals for disease control and prevention. Thus, anti‐epidemic measures can be implemented effectively, and deploying and running this system can improve the capabilities for the prevention and control of infectious diseases.