Maxime Tijskens

Dr. Maxime Tijskens

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2022 in The American Journal of Cardiology
Verified
Journal Article
Closed access
MTMaxime Tijskens
Maxime Tijskens
MBMarco Bergonti
Marco Bergonti
FSFrancesco Spera
Francesco Spera
CACiro Ascione
Ciro Ascione
JSJohan Saenen
Johan Saenen
ASAndrea Sarkozy
Andrea Sarkozy

7 February 2022 in Journal of Cardiovascular Electrophysiology
Verified
Journal Article
Closed access
PDF file
FSFrancesco Raffaele Spera
Francesco Raffaele Spera
MRMoises Rodriguez‐Mañero
Moises Rodriguez‐Mañero
ABAurora Baluja
Aurora Baluja
JSJohan Saenen
Johan Saenen
WHWim Huybrechts
Wim Huybrechts
ASAndrea Sarkozy
Andrea Sarkozy

Verified
Journal Article
Open access
PDF file
MTMaxime Tijskens
Maxime Tijskens
JAJuan Pablo Abugattas
Juan Pablo Abugattas
HTHendrik Thoen
Hendrik Thoen
ASAntanas Strazdas
Antanas Strazdas
BSBruno Schwagten
Bruno Schwagten
Yves De GreefYves De Greef
Yves De Greef
Background: Adding electroanatomical left atrial (LA) voltage mapping to cryoballoon ablation (CBA) improves validation of acute pulmonary vein isolation (PVI). Aims: To determine whether the addition of mapping can improve outcome and PVI durability. Methods: One-year outcome and PV reconnection (PVR) rate at first repeat ablation were studied in 400 AF patients in a propensity-matched analysis (age, AF type, CHA2DS2-VASc score) between Achieve catheter-guided CBA with additional EnSite LA voltage maps performed pre- and post-CBA (mapping group; N = 200) and CT- and Achieve catheter-guided CBA (control group; N = 200). Clinical success was defined as freedom of documented AF or atrial tachycardia (AT) > 30 s. PV reconnection patterns were characterized in repeat ablations. Results: At 1 year, 77 (19.25%) patients had recurrence of AF/AT, significantly lower than in the mapping group: 21 (10.5%) vs. 56 (28%), p < 0.001. Procedure time was shorter (72.2 ± 25.4 vs. 78.2 ± 29.3 min, p = 0.034) and radiation exposure lower (4465.0 ± 3454.6 Gy.cm2 vs. 5940.5 ± 4290.5 Gy.cm2, p = 0.037). Use of mapping was protective towards AF/AT recurrence (HR = 0.348; 95% CI 0.210–0.579; p < 0.001), independent of persistent AF type (HR = 1.723; 95% CI 1.034–2.872; p = 0.037), and LA diameter (HR = 1.055; 95% CI 1.015–1.096; p = 0.006). At repeat ablation (N = 90), persistent complete PVI was seen in 14/20 (70.0%) versus 23/70 (32.9%) in the mapping and conventional group, respectively (p = 0.03). Reconnection rate of the right inferior PV was lower with mapping (10.0% vs. 34,3%, p = 0.035). Conclusions: Adding electroanatomical LA voltage mapping to CBA improves 1-year clinical outcome and lowers both procedure time and radiation exposure. At repeat, use of mapping increases complete persistent PVI mainly by improving PVI durability of the RIPV.

18 April 2025 in Journal of Cardiovascular Electrophysiology
Verified
Journal Article
Closed access
MTMaxime Tijskens
Maxime Tijskens
JAJuan Pablo Abugattas
Juan Pablo Abugattas
MWMichael Wolf
Michael Wolf
BSBruno Schwagten
Bruno Schwagten
YGYves De Greef
Yves De Greef

11 May 2019 in Journal of Cardiovascular Electrophysiology
Verified
Journal Article
Closed access
PDF file
MTMaxime Tijskens
Maxime Tijskens
HHHein Heidbuchel
Hein Heidbuchel
ASAndrea Sarkozy
Andrea Sarkozy

20 July 2025 in Journal of Cardiovascular Electrophysiology
Verified
Journal Article
Closed access
MTMaxime Tijskens
Maxime Tijskens
KSK. De Schouwer
K. De Schouwer
MWM. Wolf
M. Wolf
YGY. De Greef
Y. De Greef
BSB. Schwagten
B. Schwagten