Raychelle Burks

Dr. Raychelle Burks

orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 August 2016 in Critical Reviews in Analytical Chemistry
Verified
Journal Article
Open access
MKMichael Kangas
Michael Kangas
RBRaychelle Burks
Raychelle Burks
JAJordyn Atwater
Jordyn Atwater
RLRachel M. Lukowicz
Rachel M. Lukowicz
PWPat Williams
Pat Williams
AHAndrea E. Holmes
Andrea E. Holmes
There is a significant demand for devices that can rapidly detect chemical–biological–explosive (CBE) threats on-site and allow for immediate responders to mitigate spread, risk, and loss. The key to an effective reconnaissance mission is a unified detection technology that analyzes potential threats in real time. In addition to reviewing the current state of the art in the field, this review illustrates the practicality of colorimetric arrays composed of sensors that change colors in the presence of analytes. This review also describes an outlook toward future technologies, and describes how they could possibly be used in areas such as war zones to detect and identify hazardous substances.

31 July 2009 in Analytical and Bioanalytical Chemistry
Verified
Journal Article
Closed access
PDF file
RBRaychelle Burks
Raychelle Burks
DHDavid S. Hage
David S. Hage

13 October 2017 in Journal of Chemometrics
Verified
Journal Article
Closed access
PDF file
MKMichael Kangas
Michael Kangas
RBRaychelle Burks
Raychelle Burks
JAJordyn Atwater
Jordyn Atwater
RLRachel M. Lukowicz
Rachel M. Lukowicz
BGBilly Garver
Billy Garver
AHAndrea E. Holmes
Andrea E. Holmes

1 January 2015 in Journal of Analytical Methods in Chemistry
Verified
Journal Article
Open access
PDF file
MOMacduff O. Okuom
Macduff O. Okuom
RBRaychelle Burks
Raychelle Burks
CNCrysta Naylor
Crysta Naylor
AHAndrea E. Holmes
Andrea E. Holmes
In order to determine if electronic circular dichroism (ECD) is a good tool for the qualitative evaluation of absolute configuration and enantiopurity in the absence of chiral high performance liquid chromatography (HPLC), ECD studies were performed on several prescriptions and over-the-counter drugs. Cotton effects (CE) were observed for both S and R isomers between 200 and 300 nm. For the drugs examined in this study, the S isomers showed a negative CE, while the R isomers displayed a positive CE. The ECD spectra of both enantiomers were nearly mirror images, with the amplitude proportional to the enantiopurity. Plotting the differential extinction coefficient (Δε) versus enantiopurity at the wavelength of maximum amplitude yielded linear standard curves with coefficients of determination (R2) greater than 97% for both isomers in all cases. As expected, Equate, Advil, and Motrin, each containing a racemic mixture of ibuprofen, yielded no chiroptical signal. ECD spectra of Suphedrine and Sudafed revealed that each of them is rich in 1S,2S-pseudoephedrine, while the analysis of Equate vapor inhaler is rich in R-methamphetamine.

16 April 2010 in Journal of Forensic Sciences
Verified
Journal Article
Closed access
PDF file
RBRaychelle Burks
Raychelle Burks
SPShari E. Pacquette
Shari E. Pacquette
MGMike A. Guericke
Mike A. Guericke
MWMark V. Wilson
Mark V. Wilson
DSDavid J. Symonsbergen
David J. Symonsbergen
AHAndrea Holmes
Andrea Holmes

20 July 2018 in Analytical Chemistry
Verified
Journal Article
Closed access
MKMichael Kangas
Michael Kangas
RLRachel Lukowicz
Rachel Lukowicz
JAJordyn Atwater
Jordyn Atwater
APArmando Pliego
Armando Pliego
YAYasmine Al-Shdifat
Yasmine Al-Shdifat
AHAndrea E. Holmes
Andrea E. Holmes