Zheng Shi

Dr. Zheng Shi


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 July 2024 in Electronics
Verified
Journal Article
Open access
PDF file
YLYan Liang
Yan Liang
JZJunwei Zhang
Junwei Zhang
ZSZheng Shi
Zheng Shi
HZHaibo Zhao
Haibo Zhao
YWYao Wang
Yao Wang
HZHaixiao Zhu
Haixiao Zhu
Aiming at the shortcomings of traditional fault identification methods in fault information acquisition, In the scenario of hybrid HVDC transmission system, a new fault identification method is proposed by using wavelet packet energy spectrum and convolutional neural network (CNN), which effectively solves the problem of complex fault feature extraction of hybrid HVDC transmission system. This method effectively improves the accuracy of fault identification. Firstly, tThe frequency-domain characteristics of the fault transient signal are extracted by wavelet packet transform, and the feature differences are reflected in the form of energy spectrum. Secondly, according to the extracted energy feature information, the order of fault line and fault type is identified by CNN. Finally, through example verification and algorithm comparison, it is concluded that, the mentioned model has a strong ability to identify faults, and has strong anti-noise interference and tolerance to transition resistance.

14 September 2024 in Energies
Verified
Journal Article
Open access
PDF file
ZSZheng Shi
Zheng Shi
LYLu Yan
Lu Yan
YHYingying Hu
Yingying Hu
YWYao Wang
Yao Wang
WQWenping Qin
Wenping Qin
ZZZhi Zhang
Zhi Zhang
The shared energy storage device acts as an energy hub between multiple microgrids to better play the complementary characteristics of the microgrid power cycle. In this paper, the cooperative operation process of shared energy storage participating in multiple island microgrid systems is researched, and the two-stage research on multi-microgrid operation mode and shared energy storage optimization service cost is focused on. In the first stage, the output of each subject is determined with the goal of profit optimization and optimal energy storage capacity, and the modified grey wolf algorithm is used to solve the problem. In the second stage, the income distribution problem is transformed into a negotiation bargaining process. The island microgrid and the shared energy storage are the two sides of the game. Combined with the non-cooperative game theory, the alternating direction multiplier method is used to reduce the shared energy storage service cost. The simulation results show that shared energy storage can optimize the allocation of multi-party resources by flexibly adjusting the control mode, improving the efficiency of resource utilization while improving the consumption of renewable energy, meeting the power demand of all parties, and realizing the sharing of energy storage resources. Simulation results show that compared with the traditional PSO algorithm, the iterative times of the GWO algorithm proposed in this paper are reduced by 35.62%, and the calculation time is shortened by 34.34%. Compared with the common GWO algorithm, the number of iterations is reduced by 18.97%, and the calculation time is shortened by 22.31%.

25 June 2024 in Energies
Verified
Journal Article
Open access
PDF file
ZSZheng Shi
Zheng Shi
HZHaixiao Zhu
Haixiao Zhu
HZHaibo Zhao
Haibo Zhao
PWPeng Wang
Peng Wang
YLYan Liang
Yan Liang
HLHongli Liu
Hongli Liu
In adapting to the double-high development trend of high-voltage direct current (HVDC) receiving-end power systems and solving optimization problems in emergency frequency control (EFC) supporting virtual power plants (VPPs) in large-scale power systems, a parameter estimation method for a VPP frequency response model based on a successive linear programming (SLP) method is proposed. First, a “centralized/decentralized” hierarchical control architecture for VPP participation in EFC is designed. Second, the frequency response characteristics of multiple flexible resources are scientifically analyzed, and the system frequency response (SFR) model and equivalent model of VPP are constructed. Subsequently, parameter estimation of the VPP frequency response model is carried out based on the SLP method, aiming to balance the accuracy and computational efficiency of the model. Finally, the effectiveness of the proposed methodology is verified by using PSD-BPA to simulate and test the three-zone HVDC recipient area grid.

19 July 2025 in Electronics
Verified
Journal Article
Open access
PDF file
ZSZheng Shi
Zheng Shi
YZYonghao Zhang
Yonghao Zhang
ZHZesheng Hu
Zesheng Hu
YWYao Wang
Yao Wang
YLYan Liang
Yan Liang
DADingguo An
Dingguo An
With the advancement in the “dual carbon” strategy and the integration of high proportions of renewable energy sources, AC/DC ultra-high-power grids are facing new security challenges such as commutation failure and multi-infeed coupling effects. Fault diagnosis, as an important tool for assisting power grid dispatching, is essential for maintaining the grid’s long-term stable operation. Traditional fault diagnosis methods encounter challenges such as limited samples and data quality issues under complex operating conditions. To overcome these problems, this study proposes a fault sample data enhancement method based on the Wasserstein Generative Adversarial Network with Gradient Penalty (WGAN-GP). Firstly, a simulation model of the AC/DC hybrid system is constructed to obtain the original fault sample data. Then, through the adoption of the Wasserstein distance measure and the gradient penalty strategy, an improved WGAN-GP architecture suitable for feature learning of the AC/DC hybrid system is designed. Finally, by comparing the fault diagnosis performance of different data models, the proposed method achieves up to 100% accuracy on certain fault types and improves the average accuracy by 6.3% compared to SMOTE and vanilla GAN, particularly under limited-sample conditions. These results confirm that the proposed approach can effectively extract fault characteristics from complex fault data.

24 July 2026 in Energies
Verified
Journal Article
Open access
PDF file
ZSZheng Shi
Zheng Shi
MXMin Xu
Min Xu
ZFZiyu Fu
Ziyu Fu
JDJiaojiao Deng
Jiaojiao Deng
YHYingying Hu
Yingying Hu
Liwei JuLiwei Ju
Liwei Ju
Green low-carbon data centers operate as coupled cyber-energy systems whose dispatch must coordinate renewable generation, grid exchange, battery storage, cooling load, flexible computing workload, carbon-intensity signals, and reliability constraints. This study develops and evaluates a safety-constrained deep reinforcement learning framework for source–load–storage coordinated operation of a grid-connected green data center. The operating problem is formulated as a constrained Markov decision process with state variables describing the IT load, deferrable workload backlog, renewable availability, electricity price, marginal carbon intensity, battery state of charge, server-room temperature, reserve margin, and calendar context. The action space covers grid import and export, renewable utilization, storage charge and discharge, workload shifting, and cooling control. The learning architecture combines a constrained actor–critic policy, adaptive Lagrangian safety critics, and a control barrier function (CBF)-based action shield that projects unsafe actions onto an explicitly defined operating set before plant execution. The shield is specified as a low-dimensional quadratic projection over state-dependent SOC, thermal, reserve, SLA, and grid-interface constraints, while cumulative risks are priced through Lagrangian safety budgets during policy training. The evaluation uses a controlled and auditable benchmark simulation with normalized public-data-compatible profiles, declared scenarios, random seeds, neural-network settings, and mechanism-matched baselines; it is not a telemetry-based verification or hardware certification of a deployed data center. Within this declared benchmark, the proposed safe DRL controller produces a simulated 13.1% emission reduction relative to the Rule-based controller, 95.8% renewable utilization, a normalized annual cost of 0.91, and fewer boundary contacts than the tested unconstrained, Lagrangian-only, and shield-only PPO variants. These percentages are simulator outputs relative to the stated benchmark and must not be interpreted as measured field savings. The results show how separating reward learning, cumulative safety pricing, and one-step engineering projection changes low-carbon dispatch within the specified model.