Boris Brkić

Dr. Boris Brkić

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2014 in International Journal of Mass Spectrometry
Verified
Journal Article
Closed access
BBBoris Brkić
Boris Brkić
SGStamatios Giannoukos
Stamatios Giannoukos
NFNeil France
Neil France
RMRobert Murcott
Robert Murcott
FSFabrizio Siviero
Fabrizio Siviero
STStephen Taylor
Stephen Taylor

27 September 2024 in Life
Verified
Journal Article
Open access
PDF file
EPElena Patra
Elena Patra
AKAnna Kokkinopoulou
Anna Kokkinopoulou
SWSaskia L. Wilson-Barnes
Saskia L. Wilson-Barnes
Kathryn HartKathryn Hart
Kathryn Hart
Lazaros P. GymnopoulosLazaros P. Gymnopoulos
Lazaros P. Gymnopoulos
IPIoannis Pagkalos
Ioannis Pagkalos
Mobile applications have been shown to be an effective and feasible intervention medium for improving healthy food intake in different target groups. As part of the PeRsOnalized nutriTion for hEalthy livINg (PROTEIN) European Union H2020 project, the PROTEIN mobile application was developed as an end-user environment, aiming to facilitate healthier lifestyles through artificial intelligence (AI)-based personalised dietary and physical activity recommendations. Recommendations were generated by an AI advisor for different user groups, combining users’ personal information and preferences with a custom knowledge-based system developed by experts to create personalised, evidence-based nutrition and activity plans. The PROTEIN app was piloted across different user groups in five European countries (Belgium, Germany, Greece, Portugal, and the United Kingdom). Data from the PROTEIN app’s user database (n = 579) and the PROTEIN end-user questionnaire (n = 446) were analysed using the chi-square test of independence to identify associations between personal goals, meal recommendations, and meal adherence among different gender, age, and user groups. The results indicate that weight loss-related goals are more prevalent, as well as more engaging, across all users. Health- and physical activity-related goals are key for increased meal adherence, with further differentiation evident between age and user groups. Congruency between user groups and their respective goals is also important for increased meal adherence. Our study outcomes, and the overall research framework created by the PROTEIN project, can be used to inform the future development of nutrition mobile applications and enable researchers and application designers/developers to better address personalisation for specific user groups, with a focus on user intent, as well as in-app features.

22 June 2018 in The Analyst
Verified
Journal Article
Open access
PDF file
BBBoris Brkić
Boris Brkić
NFNeil France
Neil France
SGStamatios Giannoukos
Stamatios Giannoukos
STStephen Taylor
Stephen Taylor
We report a novel portable 17 kg system based on a quadrupole mass spectrometer (QMS) with an electronic power consumption of 24 W. The system can be used for the in-field identification of gases and volatile/semivolatile organic compounds (VOCs/SVOCs). The mass analyser is a custom-made quadrupole mass filter with a Brubaker pre-filter that gives a mass range of m/z 1–500. It is an upgrade of the previous m/z 1–200 range triple filter analyser system. Analyser design was optimized using 3D numerical simulations as a performance trade-off between single and triple filter designs while maintaining high sensitivity and ease of integration. This also required enhanced design of the electronic control unit (ECU) compared to the previous triple filter ECU designs with lower power consumption, size, weight and cost of the overall system. Another major ECU improvement includes high stability of DC voltage control and ultra-low RF drift, which is important for in-field applications that require stable mass peaks for reliable quantitative analysis and continuous monitoring. Experimental results are presented for the perfluorotributylamine (PFTBA) calibrant and acetone to assess the functionality of the instrument. Performance comparison between the dual and triple filter quadrupole analysers has also been done. Mass spectra are given for methyl benzoate (cocaine simulant), piperidine (phencyclidine simulant), cyclohexanone (C4 simulant) and 2-nitrotoluene (TNT simulant) to assess potential capability for the identification of threat compounds. All spectral results show good correlation with the NIST library mass spectra with unit resolution obtained for spectral peaks within a m/z 1–400 mass range.

20 February 2024 in Sustainability
Verified
Journal Article
Open access
PDF file
DIDaria Ilić
Daria Ilić
BBBoris Brkić
Boris Brkić
MSMaja Turk Sekulić
Maja Turk Sekulić
The wellbeing of the honey bee colonies and the health of humans are connected in numerous ways. Therefore, ensuring the wellbeing of bees is a crucial component of fostering sustainability and ecological harmony. The colony collapse disorder (CCD) phenomenon was first reported in 2006 when the majority of bee colonies in Europe died out, due to an increase in infections, contamination of hives with agrochemical pesticides, and persistent organic pollutants (POPs). Only 6 years after the emergence of CCD, more than 6.5 million premature deaths were reported, as a consequence of persistent human exposure to air pollution. The insect species such as the honey bee Apis mellifera L. and the air matrix inside the beehive can be used as tools in biomonitoring, instead of traditional monitoring methods. This may have advantages in terms of cost-effective bioindicators of the environmental health status, showing the ability to record spatial and temporal pollutant variations. In this study, we present the sustainable in-field usage of the portable membrane inlet mass spectrometry (MIMS) instrument for an instant and effective determination of the level of environmental pollution by analytical identification of hive atmosphere volatile organic compound (VOC) contaminants, polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs), monocyclic aromatic hydrocarbons (BTEX) compounds, and pesticides. The samples were taken from hives located in urbanized and rural regions, highlighting variations in contamination. The MIMS results were benchmarked against a conventional laboratory sampling technique, such as GC-MS.

31 July 2023 in Journal of Breath Research
Verified
Journal Article
Closed access
MJMilena Jakšić
Milena Jakšić
ASAndrea Simeon
Andrea Simeon
DVDjordje Vujic
Djordje Vujic
SGStamatios Giannoukos
Stamatios Giannoukos
BBBoris Brkić
Boris Brkić
In the modern world, many people are changing old dietary and lifestyle habits to improve the quality of their living—to treat or just prevent possible diseases. The main goal of this pilot study was to assess the food and lifestyle impact on exhaled breath volatile organic compounds (VOCs) in various population groups. It was done by employing a recently validated portable membrane-inlet mass spectrometer—MIMS. Thus, the obtained results would also represent the additional confirmation for the employment of the new instrument in the breath analysis. The pilot study involved 151 participants across Europe, including people with overweight, obesity, type 2 diabetes mellitus, cardiovascular disease, people with poor-quality diet and professional athletes. Exhaled breath acetone, ethanol, isoprene, and n-pentane levels were determined in samples before the meal, and 120 min after the meal. Obtained basal ppbv values were mainly in accordance with previously reported, which confirms that MIMS instrument can be used in the breath analysis. Combining the quantified levels along with the information about the participants’ lifestyle habits collected via questionnaire, an assessment of the food and lifestyle impact was obtained. Notable alteration in examined VOC levels upon meal consumption was detected in more than 70% of all participants, with exception for isoprene, which was affected in about half of participants. Lifestyle parameters impact was examined using statistical analysis of variance (ANOVA) on ranks test. Statistically significant differences in basal breath VOC levels were observed among all examined population groups. Also, n-pentane and ethanol levels significantly differed in people of different ages, as well as acetone levels in people with different physical activity habits. These findings are promising for further, more focused research using MIMS technique in breath analysis.

26 November 2018 in Analytical Methods
Verified
Journal Article
Open access
PDF file
BBBoris Brkić
Boris Brkić
SGStamatios Giannoukos
Stamatios Giannoukos
STStephen Taylor
Stephen Taylor
DLDarren F. Lee
Darren F. Lee
This work uses a portable mass spectrometer (MS) for lab-based water quality monitoring of organic compounds, which are present in highly toxic nuclear waste ponds. This is due to a number of effects that such species have on storage of radioactive waste. The MS system that was used for the tests consists of a quadrupole mass spectrometer (QMS) housed in a mobile vacuum system with dual sample inlet options. The QMS uses a triple filter analyser for high performance and sensitivity to ppb levels in water. Mass spectra were obtained using a membrane sample inlet for the following organic substances: acetone, acetophenone, cyclohexanone, isophorone, 1-pentanol, 1-heptanol, propionaldehyde, ethyl acetate, ethyl propionate and odourless kerosene. Calibration curves were obtained for selected mass fragments for each of the compounds tested and showed excellent linearity (R2 ≥ 0.9835 in all cases). Spectra were also obtained for compound mixtures for acetone, cyclohexanone, acetophenone and isophorone as well as for 1-pentanol and 1-heptanol. All the tested substances were successfully detected with their spectral peaks clearly distinguished. Rise and fall membrane response times are given for specific compounds including their limits of detection (LOD), which are within the current demands of the nuclear industry.