Samafou Penabeï

Samafou Penabeï

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 December 2022 in International Journal of Environmental Analytical Chemistry
Verified
Journal Article
Closed access
SPSamafou Penabeï
Samafou Penabeï
DBDaniel Bongue
Daniel Bongue
HEHazou Eyakifama
Hazou Eyakifama
AEAlexandre Ngwa Ebongue
Alexandre Ngwa Ebongue
ABAjani Mistura Bolaji
Ajani Mistura Bolaji
MNMoïse Godfroy Kwato Njock
Moïse Godfroy Kwato Njock
The activity concentrations of natural radionuclides 226Ra, 232Th and 40K in 19 soil samples from Zabili uranium exploration area were measured using a low-background digital gamma-ray spectrometer equipped with broad energy germanium detector. The activity concentrations of 238U, 232Th, and 40K range from 16.5 to 1110.9 Bq.kg−1, 19.45 to 76.97 Bq.kg−1, and 3.28 to 839.5 Bq.kg−1, with their mean values of 478.0, 58.9, and 562.5, respectively. In addition, radiological hazard parameters from the activity concentrations obtained were assessed by estimating radium equivalent activity, external and internal hazard index, indoor and outdoor absorbed gamma dose rate and the corresponding annual effective dose, effective dose rate to different body organs and tissues, and excess lifetime cancer risk. Derived radiological hazard indices have been revised in accordance with relevant national and international legislation and guidelines. The radiological hazard parameter values were found to be above the relevant limit values for soils. In order to investigate the distribution of radionuclides and associated health hazard parameters in the study area, a statistical study was performed.

22 March 2023 in Antioxidants
Verified
Journal Article
Open access
PDF file
SPSamafou Penabeï
Samafou Penabeï
JMJintana Meesungnoen
Jintana Meesungnoen
Jean-Paul Jay-GerinJean-Paul Jay-Gerin
Jean-Paul Jay-Gerin
(1) Background: cystamine and its reduced form cysteamine have radioprotective/antioxidant effects in vivo. In this study, we use an in vitro model system to examine the behavior of cystamine towards the reactive primary species produced during the radiolysis of the Fricke dosimeter under high dose-rate irradiation conditions. (2) Methods: our approach was to use the familiar radiolytic oxidation of ferrous to ferric ions as an indicator of the radioprotective/antioxidant capacity of cystamine. A Monte Carlo computer code was used to simulate the multi-track radiation-induced chemistry of aerated and deaerated Fricke-cystamine solutions as a function of dose rate while covering a large range of cystamine concentrations. (3) Results: our simulations revealed that cystamine provides better protection at pulsed dose rates compared to conventional, low-dose-rate irradiations. Furthermore, our simulations confirmed the radical-capturing ability of cystamine, clearly indicating the strong antioxidant profile of this compound. (4) Conclusion: assuming that these findings can be transposable to cells and tissues at physiological pH, it is suggested that combining cystamine with FLASH-RT could be a promising approach to further enhance the therapeutic ratio of cancer cure.

20 September 2023 in Arabian Journal of Geosciences
Verified
Journal Article
Closed access
PDF file
SPSamafou Penabeï
Samafou Penabeï
BDBongue Daniel
Bongue Daniel
NANgwa Ebongue Alexandre
Ngwa Ebongue Alexandre
PMPeane Maleka
Peane Maleka
MAMistura Bolaji Ajani
Mistura Bolaji Ajani
KGKwato Njock Moïse Godfroy
Kwato Njock Moïse Godfroy

Verified
Journal Article
Open access
PDF file
SPSamafou Penabeï
Samafou Penabeï
JMJintana Meesungnoen
Jintana Meesungnoen
Jean-Paul Jay-GerinJean-Paul Jay-Gerin
Jean-Paul Jay-Gerin
This study conducts a comparative analysis of cystamine (RSSR), a disulfide, and cysteamine (RSH), its thiol monomer, to evaluate their efficacy as radioprotectors and antioxidants under high linear energy transfer (LET) and high-dose-rate irradiation conditions. It examines their interactions with reactive primary species produced during the radiolysis of the aqueous ferrous sulfate (Fricke) dosimeter, offering insights into the mechanisms of radioprotection and highlighting their potential to enhance the therapeutic index of radiation therapy, particularly in advanced techniques like FLASH radiotherapy. Using Monte Carlo multi-track chemical modeling to simulate the radiolytic oxidation of ferrous to ferric ions in Fricke-cystamine and Fricke-cysteamine solutions, this study assesses the radioprotective and antioxidant properties of these compounds across a variety of irradiation conditions. Concentrations were varied in both aerated (oxygen-rich) and deaerated (hypoxic) environments, simulating conditions akin to healthy tissue and tumors. Both cystamine and cysteamine demonstrate radioprotective and strong antioxidant properties. However, their effectiveness varies significantly depending on the concentration employed, the conditions of irradiation, and whether or not environmental oxygen is present. Specifically, excluding potential in vivo toxicity, cysteamine substantially reduces the adverse effects of ionizing radiation under aerated, low-LET conditions at concentrations above ~1 mM. However, its efficacy is minimal in hypoxic environments, irrespective of the concentration used. Conversely, cystamine consistently offers robust protective effects in both oxygen-rich and oxygen-poor conditions. The distinct protective capacities of cysteamine and cystamine underscore cysteamine’s enhanced potential in radiotherapeutic settings aimed at safeguarding healthy tissues from radiation-induced damage while effectively targeting tumor tissues. This differential effectiveness emphasizes the need for personalized radioprotective strategies, tailored to the specific environmental conditions of the tissue involved. Implementing such approaches is crucial for optimizing therapeutic outcomes and minimizing collateral damage in cancer treatment.

4 November 2023 in International Journal of Environmental Science and Technology
Verified
Journal Article
Closed access
PDF file
SPSamafou Penabeï
Samafou Penabeï
DBD. Bongue
D. Bongue
AMA. B. Mistura
A. B. Mistura
PMP. Maleka
P. Maleka
KDK. M. Demdah
K. M. Demdah
GKG. N. M. Kwato
G. N. M. Kwato

18 December 2023 in Molecules
Verified
Journal Article
Open access
PDF file
SPSamafou Penabeï
Samafou Penabeï
ESEsteban Sepulveda
Esteban Sepulveda
AZABDULLAH MUHAMMAD ZAKARIA
ABDULLAH MUHAMMAD ZAKARIA
JMJintana Meesungnoen
Jintana Meesungnoen
Jean-Paul Jay-GerinJean-Paul Jay-Gerin
Jean-Paul Jay-Gerin
(1) Background: Radioprotective agents have garnered considerable interest due to their prospective applications in radiotherapy, public health medicine, and situations of large-scale accidental radiation exposure or impending radiological emergencies. Cystamine, an organic diamino–disulfide compound, is recognized for its radiation-protective and antioxidant properties. This study aims to utilize the aqueous ferrous sulfate (Fricke) dosimeter to measure the free-radical scavenging capabilities of cystamine during irradiation by fast carbon ions. This analysis spans an energy range from 6 to 500 MeV per nucleon, which correlates with “linear energy transfer” (LET) values ranging from approximately 248 keV/μm down to 9.3 keV/μm. (2) Methods: Monte Carlo track chemistry calculations were used to simulate the radiation-induced chemistry of aerated Fricke–cystamine solutions across a broad spectrum of cystamine concentrations, ranging from 10−6 to 1 M. (3) Results: In irradiated Fricke solutions containing cystamine, cystamine is observed to hinder the oxidation of Fe2+ ions, an effect triggered by oxidizing agents from the radiolysis of acidic water, resulting in reduced Fe3+ ion production. Our simulations, conducted both with and without accounting for the multiple ionization of water, confirm cystamine’s ability to capture free radicals, highlighting its strong antioxidant properties. Aligning with prior research, our simulations also indicate that the protective and antioxidant efficiency of cystamine diminishes with increasing LET of the radiation. This result can be attributed to the changes in the geometry of the track structures when transitioning from lower to higher LETs. (4) Conclusions: If we can apply these fundamental research findings to biological systems at a physiological pH, the use of cystamine alongside carbon-ion hadrontherapy could present a promising approach to further improve the therapeutic ratio in cancer treatments.