Alejandro Lopez Valdes

Dr. Alejandro Lopez Valdes

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 August 2024 in Nature Medicine
Verified
Journal Article
Open access
PDF file
SMSebastian Moguilner
Sebastian Moguilner
SBSandra Baez
Sandra Baez
HHHernan Hernandez
Hernan Hernandez
JMJoaquín Migeot
Joaquín Migeot
ALAgustina Legaz
Agustina Legaz
AIAgustin Ibanez
Agustin Ibanez
Brain clocks, which quantify discrepancies between brain age and chronological age, hold promise for understanding brain health and disease. However, the impact of diversity (including geographical, socioeconomic, sociodemographic, sex and neurodegeneration) on the brain-age gap is unknown. We analyzed datasets from 5,306 participants across 15 countries (7 Latin American and Caribbean countries (LAC) and 8 non-LAC countries). Based on higher-order interactions, we developed a brain-age gap deep learning architecture for functional magnetic resonance imaging (2,953) and electroencephalography (2,353). The datasets comprised healthy controls and individuals with mild cognitive impairment, Alzheimer disease and behavioral variant frontotemporal dementia. LAC models evidenced older brain ages (functional magnetic resonance imaging: mean directional error = 5.60, root mean square error (r.m.s.e.) = 11.91; electroencephalography: mean directional error = 5.34, r.m.s.e. = 9.82) associated with frontoposterior networks compared with non-LAC models. Structural socioeconomic inequality, pollution and health disparities were influential predictors of increased brain-age gaps, especially in LAC (R² = 0.37, F² = 0.59, r.m.s.e. = 6.9). An ascending brain-age gap from healthy controls to mild cognitive impairment to Alzheimer disease was found. In LAC, we observed larger brain-age gaps in females in control and Alzheimer disease groups compared with the respective males. The results were not explained by variations in signal quality, demographics or acquisition methods. These findings provide a quantitative framework capturing the diversity of accelerated brain aging.

1 August 2013 in Hearing Research
Verified
Journal Article
Closed access
MLMyles Mc Laughlin
Myles Mc Laughlin
AVAlejandro Lopez Valdes
Alejandro Lopez Valdes
Richard B ReillyRichard B Reilly
Richard B Reilly
FZFan-Gang Zeng
Fan-Gang Zeng

15 February 2024 in Sensors
Verified
Journal Article
Open access
PDF file
GCGuilherme Correia
Guilherme Correia
MCMichael J. Crosse
Michael J. Crosse
AVAlejandro Lopez Valdes
Alejandro Lopez Valdes
EEG-enabled earbuds represent a promising frontier in brain activity monitoring beyond traditional laboratory testing. Their discrete form factor and proximity to the brain make them the ideal candidate for the first generation of discrete non-invasive brain–computer interfaces (BCIs). However, this new technology will require comprehensive characterization before we see widespread consumer and health-related usage. To address this need, we developed a validation toolkit that aims to facilitate and expand the assessment of ear-EEG devices. The first component of this toolkit is a desktop application (“EaR-P Lab”) that controls several EEG validation paradigms. This application uses the Lab Streaming Layer (LSL) protocol, making it compatible with most current EEG systems. The second element of the toolkit introduces an adaptation of the phantom evaluation concept to the domain of ear-EEGs. Specifically, it utilizes 3D scans of the test subjects’ ears to simulate typical EEG activity around and inside the ear, allowing for controlled assessment of different ear-EEG form factors and sensor configurations. Each of the EEG paradigms were validated using wet-electrode ear-EEG recordings and benchmarked against scalp-EEG measurements. The ear-EEG phantom was successful in acquiring performance metrics for hardware characterization, revealing differences in performance based on electrode location. This information was leveraged to optimize the electrode reference configuration, resulting in increased auditory steady-state response (ASSR) power. Through this work, an ear-EEG evaluation toolkit is made available with the intention to facilitate the systematic assessment of novel ear-EEG devices from hardware to neural signal acquisition.

5 March 2014 in PLOS ONE
Verified
Journal Article
Open access
PDF file
AVAlejandro Lopez Valdes
Alejandro Lopez Valdes
MLMyles Mc Laughlin
Myles Mc Laughlin
LVLaura Viani
Laura Viani
PWPeter Walshe
Peter Walshe
JSJaclyn Smith
Jaclyn Smith
Richard B ReillyRichard B Reilly
Richard B Reilly
Cochlear implants (CIs) can partially restore functional hearing in deaf individuals. However, multiple factors affect CI listener's speech perception, resulting in large performance differences. Non-speech based tests, such as spectral ripple discrimination, measure acoustic processing capabilities that are highly correlated with speech perception. Currently spectral ripple discrimination is measured using standard psychoacoustic methods, which require attentive listening and active response that can be difficult or even impossible in special patient populations. Here, a completely objective cortical evoked potential based method is developed and validated to assess spectral ripple discrimination in CI listeners. In 19 CI listeners, using an oddball paradigm, cortical evoked potential responses to standard and inverted spectrally rippled stimuli were measured. In the same subjects, psychoacoustic spectral ripple discrimination thresholds were also measured. A neural discrimination threshold was determined by systematically increasing the number of ripples per octave and determining the point at which there was no longer a significant difference between the evoked potential response to the standard and inverted stimuli. A correlation was found between the neural and the psychoacoustic discrimination thresholds (R2 = 0.60, p<0.01). This method can objectively assess CI spectral resolution performance, providing a potential tool for the evaluation and follow-up of CI listeners who have difficulty performing psychoacoustic tests, such as pediatric or new users.

6 March 2020 in Clinical Otolaryngology
Verified
Journal Article
Closed access
PDF file
CSCristina Simões‐Franklin
Cristina Simões‐Franklin
IFIsobel Flood
Isobel Flood
SSStephen Sechler
Stephen Sechler
AVAlejandro Lopez Valdes
Alejandro Lopez Valdes
SWSaskia M. Waechter
Saskia M. Waechter
LVLaura Viani
Laura Viani

1 May 2017
Verified
Conference Paper
Closed access
SSStephen D. Sechler
Stephen D. Sechler
AVAlejandro Lopez Valdes
Alejandro Lopez Valdes
SWSaskia M. Waechter
Saskia M. Waechter
CSCristina Simoes-Franklin
Cristina Simoes-Franklin
LVLaura Viani
Laura Viani
Richard B ReillyRichard B Reilly
Richard B Reilly
Localizing sounds in our environment is a fundamental perceptual ability. However, methods to assess sound localization ability are often cumbersome, requiring large speaker array systems. In adults with sensorineural hearing loss who are fitted with cochlear implant (CIs), sound localization is known to improve when bilateral CIs are used compared to a single CI. This study proposes a portable virtual reality (VR) tool for measuring sound localization in bilateral cochlear implant (CI) users. Head related transfer functions (HRTFs) were used to replicate 3-dimensional sounds delivered to the users via headphones or a direct connect (DC) CI audio cable. Users wearing the VR headset were then instructed to turn and face these sound sources. From measurements of head position and velocity, objective measures of accuracy were derived. Pilot testing of the device was conducted with 4 bilateral CI participants and 12 normal hearing (NH) participants. Results showed that NH listeners performed better than CI users in all metrics. Bilateral CI users performed above chance level when presented with sounds to their first implanted ear only or to both implants simultaneously. Compared to previously reported localization studies, NH listeners demonstrated lower performance using this VR system. This study provides a foundation for objective sound localization testing in bilateral CI users in a clinical setting.