Summary: A 22‐year‐old donkey ( Equus asinus ) mare was presented for investigation of a 3‐day history of lethargy and anorexia. Serum biochemistry profile revealed severe increased liver‐derived enzymes. Abdominal ultrasound demonstrated several large round cysts in the liver. Broad‐spectrum antimicrobials and anti‐inflammatory therapy were started. However, exacerbation of the clinical signs occurred, and the donkey was euthanised. Necropsy and histopathological evaluation showed multiple hydatid cysts with protoscoleces from Echinocococcus spp. in the liver with replacement of parenchyma by fibrosis accompanied by liver atrophy, severe ascites and thorax effusion. The present report describes the first case of a molecularly confirmed Echinococcus equinus infection in a donkey in northern Switzerland.
Summary: A 25‐year‐old Irish sport horse was presented for investigation of a 7‐day history of apathy and lethargy. Clinical examination revealed tachycardia, tachypnoea, distended, pulsating jugular veins and ventral oedema. Serum biochemistry showed azotaemia. The ultrasonographic examination of the abdomen and the thorax revealed peritoneal, pleural and pericardial effusion. Following the assessment, the mare was euthanised and a full post‐mortem examination was performed. The main findings included a ruptured mass in the left atrium of the heart with subsequent haemopericardium. By histological examination and immunoreactivity for thyroglobulin‐1, the cardiac mass could be further classified as a thyroid carcinoma. As there was no evidence of thyroid neoplasia in the rest of the carcass, it is likely that the neoplasia originated from ectopic thyroid tissue in the heart. Additional findings included multiple intestinal haemangiomas and perianal melanomas. The case report indicates that cardiac thyroid carcinoma may be a possible differential diagnosis in horses diagnosed with congestive heart failure.
Left atrial mechanical dysfunction is common in horses following the treatment of atrial fibrillation (AF). This study aimed to evaluate the use of an acoustic cardiography monitor (Audicor®) in quantifying cardiac mechanical and hemodynamic function in horses with AF before and after treatment and to correlate these findings with echocardiographic measures. Twenty-eight horses with AF and successful transvenous electrical cardioversion were included. Audicor® recordings with concomitant echocardiographic examinations were performed one day before, one day after, and two to seven days after cardioversion. Key variables measured by Audicor® included electromechanical activating time (EMAT), heart rate-corrected EMATc, left ventricular systolic time (LVST), heart rate-corrected LVSTc, systolic dysfunction index (SDI), and intensity and persistence of the third and fourth heart sound (S3, S4). A repeated-measures ANOVA with Tukey’s test was used to compare these variables over time, and linear regression and Bland–Altman analyses were applied to assess associations with echocardiographic findings. Following conversion to sinus rhythm, there was a significant decrease in EMATc and LVSTc (p < 0.0001) and a significant increase in LVST (p = 0.0001), indicating improved ventricular systolic function, with strong agreement between Audicor® snapshot and echocardiographic measures. However, S4 quantification did not show clinical value for assessing left atrial function after conversion.
Mitral and aortic valve insufficiencies have been commonly reported in horses. The objective of this study was to establish the use of acoustic cardiography (Audicor®) in horses with aortic (AI) or mitral valve insufficiency (MI). A total of 17 healthy horses, 18 horses with AI, and 28 horses with MI were prospectively included. None of the horses was in heart failure. Echocardiography and Audicor® analyses were conducted. Electromechanical activating time (EMAT), rate-corrected EMATc, left ventricular systolic time (LVST), rate-corrected LVSTc, and intensity and persistence of the third and fourth heart sound (S3, S4) were reported by Audicor®. Graphical analysis of the three-dimensional (3D) phonocardiogram served to visually detect murmurs. Audicor® snapshot variables were compared between groups using one-way ANOVA followed by Tukey’s multiple-comparisons test. The association between Audicor® snapshot variables and the corresponding echocardiographic variables was investigated by linear regression and Bland–Altman analyses. Heart murmurs were not displayed on Audicor® phonocardiograms. No significant differences were found between Audicor® variables obtained in clinically healthy horses and horses with valvular insufficiency. The Audicor® device is unable to detect heart murmurs in horses. Audicor® variables representing cardiac function are not markedly altered, and their association with corresponding echocardiographic variables is poor in horses with valvular insufficiency that are not in heart failure.