Guanlong Zhou

Dr. Guanlong Zhou


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 March 2024 in Sensors
Verified
Journal Article
Open access
PDF file
GZGuanlong Zhou
Guanlong Zhou
LLLiyan Li
Liyan Li
YZYan Zhou
Yan Zhou
Xinyu ChenXinyu Chen
Xinyu Chen
The refractive index of seawater is one of the essential parameters in ocean observation, so it is necessary to achieve high-precision seawater refractive index measurements. In this paper, we propose a method for measuring the refractive index of seawater, based on a position-sensitive detector (PSD). A theoretical model was established to depict the correlation between laser spot displacement and refractive index change, utilizing a combination of a position-sensitive detector and laser beam deflection principles. Based on this optical measurement method, a seawater refractive index measurement system was established. To effectively enhance the sensitivity of refractive index detection, a focusing lens was incorporated into the optical path of the measuring system, and simulations were conducted to investigate the impact of focal length on refractive index sensitivity. The calibration experiment of the measuring system was performed based on the relationship between the refractive index of seawater and underwater pressure (depth). By measuring laser spot displacement at different depths, changes in displacement, with respect to both refractive index and depth, were determined. The experimental results demonstrate that the system exhibits a sensitivity of 9.93×10−9 RIU (refractive index unit), and the refractive index deviation due to stability is calculated as ±7.54×10−9 RIU. Therefore, the feasibility of this highly sensitive measurement of seawater refractive index is verified. Since the sensitivity of the refractive index measurement of this measurement system is higher than the refractive index change caused by the wake of underwater vehicles, it can also be used in various applications for underwater vehicle wake measurement, as well as seawater refractive index measurement, such as the motion state monitoring of underwater navigation targets such as AUVs and ROVs.

7 February 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
GZGuanlong Zhou
Guanlong Zhou
LLLiyan Li
Liyan Li
YZYan Zhou
Yan Zhou
Xinyu ChenXinyu Chen
Xinyu Chen
The refractive index of seawater is one of the essential parameters in ocean observation, so it is necessary to achieve high precision seawater refractive index measurement. In this paper, we propose a method for measuring the refractive index of seawater based on a Position Sensitive Detector (PSD). Theoretical model is established to depict the correlation between laser spot displacement and refractive index change, utilizing a combination of position sensitive detector and laser beam deflection principle. Based on this optical measurement method, a seawater refractive index measurement system was established. To effectively enhance the sensitivity of refractive index detection, a focusing lens was incorporated into the optical path of the measuring system, and simulations were conducted to investigate the impact of focal length on refractive index sensitivity. The calibration experiment of the measuring system was performed based on the relationship between refractive index of seawater and underwater pressure (depth). By measuring laser spot displacement at different depths, changes in displacement with respect to both refractive index and depth were determined. Experimental results demonstrate that the system exhibits a sensitivity of 9.9277×10−9RIU (refractive index unit), the refractive index deviation due to stability is calculated as ±7.545×10−9RIU. Thereby the feasibility of highly sensitive measurement of seawater refractive index is verified.

14 July 2024 in Sensors
Verified
Journal Article
Open access
PDF file
GZGuanlong Zhou
Guanlong Zhou
LLLiyan Li
Liyan Li
YZYan Zhou
Yan Zhou
Xinyu ChenXinyu Chen
Xinyu Chen
The seawater refractive index is an essential parameter in ocean observation, making its high-precision measurement necessary. This can be effectively achieved using a position-sensitive detector-based measurement system. However, in the actual measurement process, the impact of the jitter signal measurement error on the results cannot be ignored. In this study, we theoretically analysed the causes of long jitter signals during seawater refractive index measurements and quantified the influencing factors. Through this analysis, it can be seen that the angle between the two windows in the seawater refractive index measurement area caused a large error in the results, which could be effectively reduced by controlling the angle to within 2.06°. At the same time, the factors affecting the position-sensitive detector’s measurement accuracy were analysed, with changes to the background light, the photosensitive surface’s size, and the working environment’s temperature leading to its reduction. To address the above factors, we first added a 0.9 nm bandwidth, narrow-band filter in front of the detector’s photosensitive surface during system construction to filter out any light other than that from the signal light source. To ensure the seawater refractive index’s measuring range, a position-sensitive detector with a photosensitive surface size of 4 mm × 4 mm was selected; whereas, to reduce the working environment’s temperature variation, we partitioned the measurement system. To validate the testing error range of the optimised test system, standard seawater samples were measured under the same conditions, showing a reduction in the measurement system’s jitter signal from 0.0022 mm to 0.0011 mm, before and after optimisation, respectively, as well as a reduction in the refractive index’s deviation. The experimental results show that the refractive index of seawater was effectively reduced by adjusting the measurement system’s optical path and structure.

12 July 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
GZGuanlong Zhou
Guanlong Zhou
QLQin Liu
Qin Liu
HWHu Wang
Hu Wang
LLLiyan Li
Liyan Li
YZYan Zhou
Yan Zhou
Xinyu ChenXinyu Chen
Xinyu Chen
The study of underwater vehicle wake detection is of significant importance within the field of target detection, localisation and tracking of underwater vehicles. Given that propellers are the propellers of modern ships and underwater vehicles, the propeller wake field represents the principal target source for wake detection in underwater vehicles. The objective of this paper is to propose a method for measuring the wake of an underwater propeller based on a position-sensitive detector. A theoretical model of the relationship between the laser spot displacement and the change of refractive index of the wake field is established on the basis of the principle of laser beam deflection. A prototype experimental setup for underwater propeller wake measurement was constructed based on the aforementioned optical measurement method. Furthermore, the simulation of the propeller wake flow field with strong density stratification and linear density stratification was conducted based on the experimental setup. In the experiment, a three-bladed propeller with a diameter of 39mm was selected, the water tank size was 980mm×380mm×380mm, and the laser acted at a distance of 550 mm from the propeller. The experimental results indicate that the wake dissipation time of the propeller in a strong density-stratified water environment is approximately 800s. Following the stabilization of the wake field density, the laser spot position is observed to be stable at 0.341 mm, with a corresponding refractive index change of 2.99×10-6 RIU. The wake dissipation time of the propeller in a linear density-stratified water environment is approximately 750 s. Once the wake field density has reached a stable state, the laser spot position is found to be 0.441mm, corresponding to a refractive index change of 3.87×10-6 RIU. These experimental results are found to be in general agreement with the simulation results of the propeller wake field. A comparison of the experimental device-based wake measurements with the CTD-based wake measurements reveals a consistent trend.

6 August 2024 in Photonics
Verified
Journal Article
Open access
PDF file
GZGuanlong Zhou
Guanlong Zhou
QLQin Liu
Qin Liu
HWHu Wang
Hu Wang
LLLiyan Li
Liyan Li
YZYan Zhou
Yan Zhou
Xinyu ChenXinyu Chen
Xinyu Chen
The study of underwater vehicle wake detection is of significant importance within the field of target detection, localisation, and tracking of underwater vehicles. Given that propellers are the propellers of modern ships and underwater vehicles, the propeller wake field represents the principal target source for wake detection in underwater vehicles. The objective of this paper is to propose a method for measuring the wake of an underwater propeller based on a position-sensitive detector. A theoretical model of the relationship between the laser spot displacement and the change in the refractive index of the wake field is established on the basis of the principle of laser beam deflection. A prototype experimental setup for underwater propeller wake measurement was constructed based on the aforementioned optical measurement method. Furthermore, the simulation of the propeller wake flow field with strong density stratification and linear density stratification was conducted based on the experimental setup. Furthermore, experiments were conducted to detect the flow field of a propeller wake. The experimental results indicate that the wake dissipation times of the propeller in a strong density-stratified water environment are approximately 800 s and 750 s. Following the stabilisation of the wake field density, the laser spot position is observed to be stable at 0.341 mm and 0.441 mm, respectively, with a corresponding refractive index change of 2.99 × 10−6 RIU (refractive index unit) and 3.87 × 10−6 RIU, respectively. These experimental results are found to be in general agreement with the simulation results of the propeller wake field. A comparison of the experimental wake measurements based on the device with the wake measurements based on a CTD (conductivity–temperature–depth) device reveals a consistent trend. The realisation of this detection technique is of great significance for the advancement of research in the field of optical detection of underwater vehicle wake streams.

26 June 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
GZGuanlong Zhou
Guanlong Zhou
LLLiyan Li
Liyan Li
YZYan Zhou
Yan Zhou
Xinyu ChenXinyu Chen
Xinyu Chen
The refractive index of seawater is one of the essential parameters in ocean observation, so it is necessary to achieve high-precision seawater refractive index measurements. A seawater refractive index measurement system based on position-sensitive detectors is an effective means to achieve high-precision measurement of seawater refractive index. However, in the actual seawater refractive index measurement process, the impact of the measurement error caused by the jitter signal obtained from the measurement on the measurement results cannot be ignored. In this paper, we theoretically analyse the causes of the long jitter signals during seawater refractive index measurement and quantify the influencing factors. Through the analysis, it can be seen that the angle between the two windows in the refractive index measurement area of seawater causes a great error on the measurement results, so the angle between the two windows should be controlled within 2.06° in order to effectively reduce the measurement error. At the same time, the factors affecting the measurement accuracy of the position-sensitive detector are analysed, and the factors leading to the reduction of the measurement accuracy of the position-sensitive detector are mainly the background light, the size of the photosensitive surface, and the change of the temperature of the working environment. For the above factors, we add a narrow-band filter with a bandwidth of 0.9nm in front of the photosensitive surface of the position-sensitive detector during the construction of the measurement system, so as to filter out stray light other than the signal light source. On the premise of ensuring the measuring range of the refractive index of seawater, a position-sensitive detector with a photosensitive surface size of 4 mm×4 mm was selected. In order to reduce the temperature variation of the working environment of the position-sensitive detector, the measurement system was partitioned. In order to validate the testing error range of the optimised test system, standard seawater samples under the same conditions were measured. It can be seen that the jitter signal of the measurement system has been reduced from 0.0022mm before the optimisation to 0.0011mm after the optimisation, and the deviation of the refractive index has been reduced by 1.09×10−8RIU. The experimental results show that the refractive index of seawater has been effectively reduced by adjusting the optical path and the structure of the seawater refractive index measurement system.