Dewang Yang

Dr. Dewang Yang


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 March 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Fengxin XinFengxin Xin
Fengxin Xin
JLJie Li
Jie Li
JGJinjia Guo
Jinjia Guo
DYDewang Yang
Dewang Yang
YWYong Wang
Yong Wang
ZLZhishen Liu
Zhishen Liu
Monitoring of CO2 column concentrations is valuable for atmospheric research. A mobile open-path system was developed based on tunable diode laser absorption spectroscopy (TDLAS) to measure atmospheric CO2 column concentrations. A laser beam was emitted downward from a distributed feedback diode laser at 2 μm and then reflected by the retroreflector array on the ground. We measured the CO2 column concentrations over the 20 and 110 m long vertical path. Several single-point sensors were distributed at different heights to provide comparative measurements for the open-path TDLAS system. The results showed that the minimum detection limit of system was 0.52 ppm. Some similarities were observed in trends from the open-path TDLAS system and these sensors, but the average of these sensors was more consistent with the open-path TDLAS system values than the single-point measurement. These field measurements demonstrate the feasibility of open-path TDLAS for measuring the CO2 column concentration and monitoring carbon emission over large areas.

1 December 2017 in Sensors
Verified
Journal Article
Open access
PDF file
DYDewang Yang
Dewang Yang
JGJinjia Guo
Jinjia Guo
LCLiu Chunhao
Liu Chunhao
QLQingsheng Liu
Qingsheng Liu
RZRonger Zheng
Ronger Zheng
Raman spectroscopy has great potential as a tool in a variety of hydrothermal science applications. However, its low sensitivity has limited its use in common sea areas. In this paper, we develop a near-concentric cavity-enhanced Raman spectroscopy system to directly detect bicarbonate in seawater for the first time. With the aid of this near-concentric cavity-enhanced Raman spectroscopy system, a significant enhancement in HCO3− detection has been achieved. The obtained limit of detection (LOD) is determined to be 0.37 mmol/L—much lower than the typical concentration of HCO3− in seawater. By introducing a specially developed data processing scheme, the weak HCO3− signal is extracted from the strong sulfate signal background, hence a quantitative analysis with R2 of 0.951 is made possible. Based on the spectra taken from deep sea seawater sampling, the concentration of HCO3− has been determined to be 1.91 mmol/L, with a relative error of 2.1% from the reported value (1.95 mmol/L) of seawater in the ocean. It is expected that the near-concentric cavity-enhanced Raman spectroscopy system could be developed and used for in-situ ocean observation in the near future.