Yang Zhou

Dr. Yang Zhou

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2019
Verified
Conference Paper
Closed access
ZZZhen Zhang
Zhen Zhang
LHLi Huabao
Li Huabao
YZYang Zhou
Yang Zhou
HJHuang Jian
Huang Jian
Space-Time Image Velocimetry (STIV) is a time-averaged velocity estimation method, which has been used for nonintrusive flow measurements from micro scale to large scale over the past decade. It takes a testing line as the Interrogation Area (IA), and detects the texture orientation of a generated Space-Time Image to determine the 1D velocity. Since STIV is superior to the Large-Scale Particle Image Velocimetry (LSPIV) in spatial resolution and time complexity, it has great potential in real-time monitoring of river flow. However, its practicality is still limited by the deficiencies of performance evaluation and sensitivity analysis due to its complexity and uncertainty. To simplify the detection of texture orientation in spatial domain, an FFT-STIV method was proposed based on Fast Fourier Transform, which detected the orientation of magnitude spectra in frequency domain. Then, a theoretical evaluation was provided, including measuring accuracy, measuring range and computational complexity. Finally, the sensitivities of image size, sampling rate, edge threshold, calibration accuracy, and tracing condition were analyzed based on a Rolling Painting Model (RPM). Results showed that the random errors of FFT-STIV could be controlled within ± 5%, where the systematic error was about ± 1%.

8 February 2024 in Symmetry
Verified
Journal Article
Open access
PDF file
YZYang Zhou
Yang Zhou
JZJin Zhao
Jin Zhao
ZWZhixi Wu
Zhixi Wu
Power converters can convert the electrical energy output by power source into specific forms required by target device. They are widely used in various fields such as electrification, transportation, and power systems, and are the core components of the systems. Power converters are composed of power semiconductor devices (such as IGBTs), which are prone to failure due to abnormal conditions and aging degradation, leading to power converter faults. Therefore, over the past twenty years, extensive fault diagnosis methods for power converters have been studied and proposed. Among them, symmetry-based methods have the characteristics of rapid diagnosis speed and strong robustness, but so far there’s no systemic summary of such methods. Therefore, this paper reviews the relevant research on fault diagnosis of power converters based on symmetry in recent years, analyzes the mathematical principles of these methods, and compares their diagnostic performance. In addition, two factors that may have an influence on the symmetry are pointed out. This paper provides references and suggestions for the future development and research of power converter fault diagnosis.

13 March 2017 in Optics Express
Verified
Journal Article
Open access
PDF file
JJJialin Jiang
Jialin Jiang
JSJunqiang Sun
Junqiang Sun
YZYang Zhou
Yang Zhou
JGJianfeng Gao
Jianfeng Gao
HZHeng Zhou
Heng Zhou
RZRuiwen Zhang
Ruiwen Zhang
We design a CMOS-compatible Distributed Bragg Reflector (DBR) laser based on highly uniaxial tensile stressed germanium. Our design first incorporates three critical elements including high uniaxial tensile stress, low loss optical resonator and heterojunction for electrical injection. A threshold current density of 80 kA/cm2 and an internal quantum efficiency of 8.5% are estimated when the Shockley–Reed–Hall (SRH) lifetime is chosen to be 3 ns. Furthermore, the performance of the DBR laser can be enhanced by improving the crystal quality and carefully designing the p-n junction. The simulation results also indicate that the limitation of the improvement of threshold current density and internal quantum efficiency are 29 kA/cm2 and 19.6%, resulting from the Auger recombination. The influences of strain and n-type doping on the threshold current density and the internal quantum efficiency are discussed. The proposed DBR laser offers a new approach to realize on-chip light source for silicon photonics.

28 June 2023 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
ZWZhixi Wu
Zhixi Wu
JZJin Zhao
Jin Zhao
LYLiu Yang
Liu Yang
YZYang Zhou
Yang Zhou
The T-type inverter plays an essential role in grid-tied high-performance power generation systems, but its reliability is risky due to the open-circuit fault of transistors. In the grid-tied T-type inverter diagnosis, modulation index regulation has a significant effect on the fault distortion of load currents. An online open-circuit fault diagnosis method is proposed in this paper for the grid-tied T-type inverter based on specific frequency calculation, considering the modulation index regulation. At first, variations of the three-phase currents under healthy and faulty conditions are deeply analyzed. Then, the fundamental, DC and second frequency components of the three-phase currents are extracted by equivalent spectrum calculation to perform fault detection, fault phase location, and fault transistor location. The cost of the calculation is small, and no additional hardware is required. At last, the effectiveness of the proposed method is verified by experimental results.

15 January 2026 in IEEE Transactions on Transportation Electrification
Verified
Journal Article
Closed access
YZYang Zhou
Yang Zhou
JZJin Zhao
Jin Zhao
WXWanting Xiang
Wanting Xiang
LYLiu Yang
Liu Yang
Fault diagnosis is essential to ensure the reliability and continuous operation of power converter systems. Despite significant progress over the years, the applicability of diagnosis methods in transient processes remains limited, hindering their practical application, especially in transportation electrification. To tackle this issue, a diagnosis method for voltage-source inverter (VSI) power switch open-circuit (OC) faults with superior transient adaptability is proposed. The method firstly transforms the three-phase (3P) current into a two-phase orthogonal coordinate system and then analyzes the current vector trajectory under different fault conditions. A fast fault detection method is then developed based on trajectory analysis. Furthermore, the trajectory is converted into a 2-D binary matrix, which is then recognized by a lightweight convolutional neural network (CNN) to locate the fault. Compared to existing methods, the proposed method significantly expands the diagnostic range while maintaining high accuracy, particularly excelling in handling transient processes. Physical experiments have verified the method’s performance across a wide range of operating conditions.

1 October 2026 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
YZYang Zhou
Yang Zhou
JZJin Zhao
Jin Zhao
LYLiu Yang
Liu Yang
KRKang Ren
Kang Ren
The data-driven-based fault diagnostic methods have continued to emerge in power electronics systems in recent years. Among them, though the methods that convert one-dimensional (1-D) electrical signals into two-dimensional (2-D) images for classification have shown promise, they often suffer from information loss or excessive computational burden. This article refines the Gramian angular field (GAF) theory and proposes a lossless and efficient method for transforming time series into images, termed extended Gramian angular field (EGAF). Building upon EGAF, an efficient and robust fault diagnostic method is proposed, with implementation demonstrated on a two-level (2L) three-phase (3P) voltage-source-inverter (VSI). The diagnostic method first extracts the current time series under different faults through Clarke transformation and zero-crossing detection, then converts the windowed time series into 2-D matrices using EGAF to construct the diagnostic dataset, and finally implements fault classification through a lightweight convolutional neural network (CNN). The proposed diagnostic method achieved an accuracy of 98.64%, and the experimental results demonstrate its high performance.