Gema Paniagua

Dr. Gema Paniagua


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 May 2024 in Heliyon
Verified
Journal Article
Open access
DSDulce L. Soliz
Dulce L. Soliz
GPGema Paniagua
Gema Paniagua
JMJuan Muñoz-Arnanz
Juan Muñoz-Arnanz
JBJUAN CARLOS BRAVO-YAGÜE
JUAN CARLOS BRAVO-YAGÜE
PHPilar Fernández Hernando
Pilar Fernández Hernando
RGRosa M. Garcinuño
Rosa M. Garcinuño
The knowledge of the polymeric composition of microplastics (MPs) is interesting because offers useful information on the resistance, durability, and degradability of these materials, also allowing progress in the control of this contamination. However, there is currently a lack of reliable standardized methods for the identification, and characterization of the plastic microparticles. This work uses different techniques in a complementary manner for the identification, and characterization of MPs that more frequently are found in the environment. A total of 10 types of plastics were collected (polystyrene (PS), polyethylene terephthalate (PETE), polyethylene (PE), high- and low-density polyethylene (HDPE and LDPE, respectively), polyvinyl chloride (PVC), polypropylene (PP), polytetrafluoroethylene (PTFE), Polyamide (PA, Nylon 6,6) and poly-carbonate (PC)) and their chemical identification were analyzed by reflectance-attenuated infrared (FTIR-ATR). Furthermore, the samples were observed using light microscopy, and scan-ning electron microscopy (SEM). Also, staining with 12 different dyes was performed to improve the identification of microplastics. The results of this study revealed that PETE, PE, HDPE and LDPE, whose SEM images exhibited smoothness and flat uniformity of their surface, were not (or less) susceptible to adsorb staining solutions while PP, PA, PVC, and PTFE, were capable of adsorbing the dye solutions.

4 May 2025 in Chemosensors
Verified
Journal Article
Open access
PDF file
JBJUAN CARLOS BRAVO-YAGÜE
JUAN CARLOS BRAVO-YAGÜE
GPGema Paniagua
Gema Paniagua
RGRosa M. Garcinuño
Rosa M. Garcinuño
MGM. Asunción García-Mayor
M. Asunción García-Mayor
PHPilar Fernández Hernando
Pilar Fernández Hernando
This review offers a comprehensive examination of the development and current state of the art in the field of molecularly imprinted polymer (MIP)-based colorimetric sensors, focusing on their potential for the rapid detection of organic compounds. These MIP-sensors are gaining considerable attention due to their distinctive capacity to modify sensor surfaces by creating recognition cavities within the polymer matrix, providing a versatile and highly selective platform for detecting a broad spectrum of analytes. This review systematically examines different types of MIP-based colorimetric sensors, attending to the target analyte, highlighting their applications in on-site sample detection, drug monitoring, environmental analysis, and food safety detection. The integration of novel technologies, such as nanozymes and smartphone-based detection, which enhance the capabilities of colorimetric MIP sensors, is also addressed. The sensors are particularly valuable due to their low cost, rapid response times, portability, and ease of use. Finally, the review outlines the future challenges for the development of MIP-based colorimetric sensors, focusing on overcoming existing limitations, improving sensor performance, and expanding their applications across various fields.

1 July 2021 in Food Chemistry
Verified
Journal Article
Open access
Raquel CañadasRaquel Cañadas
Raquel Cañadas
EGEsther Garrido Gamarro
Esther Garrido Gamarro
RGRosa M. Garcinuño
Rosa M. Garcinuño
GPGema Paniagua
Gema Paniagua
PHP. Fernández Hernando
P. Fernández Hernando
A new matrix solid-phase dispersion (MSPD) extraction methodology, combined with high-performance liquid chromatography equipped with a diode-array detector, was developed and validated for the simultaneous determination of 10 compounds in mussels from Galician Rias (Spain). These pollutants are compounds commonly used for plastic production as additives, as well as common plastic contaminants. The compounds selected were bisphenol-A, bisphenol-F, bisphenol-S, nonylphenol-9, nonylphenol, diethyl phthalate, dibutyl phthalate, di-2-ethylhexyl phthalate, dichlorodiphenyltrichloroethane, dichlorodiphenyldichloroethane, and dichlorodiphenyldichloroethylene. The parameters affecting the MSPD extraction efficiency such as the type of sorbent, mass sample-sorbent ratio, and extraction solvent were optimised. The proposed method provided satisfactory quantitative recoveries (80-100%), with relative standard deviations lower than 7%. In all cases, the matrix-matched calibration curves were linear in the concentration range of 0.32-120.00 µg/kg, with quantification limits of 0.25-16.20 µg/kg. The novel developed MSPD-high-performance liquid chromatography methodology provided good sensitivity, accuracy, and repeatability for quality control analysis in mussels.


3 November 2023 in Polymers
Verified
Journal Article
Open access
PDF file
RGRosa M. Garcinuño
Rosa M. Garcinuño
ECEduardo José Collado
Eduardo José Collado
GPGema Paniagua
Gema Paniagua
JBJUAN CARLOS BRAVO-YAGÜE
JUAN CARLOS BRAVO-YAGÜE
PHPilar Fernández Hernando
Pilar Fernández Hernando
This paper describes a new methodology for carrying out quantitative extraction of cloxacillin from drinking and river water samples using a molecularly imprinted polymer (MIP) as a selective sorbent for solid-phase extraction (MISPE). Several polymers were synthesized via thermal polymerization using cloxacillin as a template, methacrylic acid (MAA) as a functional monomer, ethyleneglycoldimethacrylate (EGDMA) as a cross-linker and different solvents as porogens. Binding characteristics of the adequate molecularly imprinted and non-imprinted (NIP) polymers were evaluated via batch adsorption assays following the Langmuir and Freundlich isotherms and Scatchard assays. The parameters related to the extraction approach were studied to select the most appropriate polymer for cloxacillin determination. Using the optimized MIP as the SPE sorbent, a simple sample treatment methodology was combined with high-performance liquid chromatography (HPLC) to analyze cloxacillin residues in drinking and river water. Under the optimum experimental conditions, the MISPE methodology was validated using spiked samples. The linearity for cloxacillin was assessed within the limits of 0.05–1.5 µg L−1 and the recovery percentage was higher than 98% (RSD < 4%). The limits of detection and limits of quantification were 0.29 and 0.37 µg L−1 and 0.8 and 0.98 µg L−1 for drinking and river water, respectively. The selectivity of MIP against other ß-lactam antibiotics with similar structures (oxacillin, cefazoline, amoxicillin and penicillin V) was studied, obtaining a good recovery higher than 85% for all except cefazoline. The proposed MISPE-HPLC methodology was successfully applied for the detection of cloxacillin in drinking water from Canal de Isabel II (Madrid) and river water from the Manzanares River (Madrid).

27 February 2024 in Polymers
Verified
Journal Article
Open access
PDF file
ATAna María Gil Tejedor
Ana María Gil Tejedor
JBJUAN CARLOS BRAVO-YAGÜE
JUAN CARLOS BRAVO-YAGÜE
GPGema Paniagua
Gema Paniagua
RGRosa M. Garcinuño
Rosa M. Garcinuño
PHPilar Fernández Hernando
Pilar Fernández Hernando
In this research, a molecularly imprinted polymer (MIP) was synthesized by precipitation polymerization using oxazepam (OZ) as a template molecule and was subsequently applied as a selective sorbent for the extraction of diazepam (DZP) and its metabolites in urine samples using an SPE cartridge. OZ, temazepam (TZ), nordiazepam (NZ) and DZP were analyzed in the final extracts by high-performance liquid chromatography with diode array detection (HPLC-DAD). The SPE extraction steps were optimized, and the evaluation of an imprinting factor was carried out. The selectivity of the method for OZ versus structurally related benzodiazepines (BZDs), such as bromazepam (BRZ), tetrazepam (TTZ) and halazepam (HZ), was investigated. Under the optimum conditions, the proposed methodology provided good linearity in the range of 10–1500 ng/mL, with limit of detection values between 13.5 and 21.1 ng/mL and recovery levels for DZP and its metabolites from 89.0 to 93.9% (RSD ≤ 8%) at a concentration level of 1000 ng/mL. The proposed method exhibited good selectivity, precision and accuracy and was applied to the analysis of urine samples from a real case of DZP intake.