Objectives. The purpose of this study was to review the experiences with transcatheter closure of mitral PVL after surgical valve replacement. Background. Transcatheter closure of paravalvular leak (PVL) is an intricate alternative to surgical closure. But it represents one of the most intricate procedures in the field of structural heart interventions, especially for patients with mitral PVL. Methods. From January 2015 through January 2019, 35 patients with mitral PVL after valve replacement underwent transcatheter closure. We reviewed the catheter techniques, perioperative characteristics, and prognosis. The median follow-up was 26 (348) months. Results. Acute procedural success was achieved in 33/35 (94.3) patients. Twenty-five patients had single mitral prosthetic valve replacements; 10 had combined aortic and mitral prosthetic valve replacements previously; 28 had mechanical valves; and 7 had bioprosthetic valves. All percutaneous procedures were performed with local anesthesia except for seven transapical cases with general anesthesia. Multiple approaches were used: transfemoral, transapical, and transseptal via an arteriovenous loop. Multiple devices were deployed. There were no hospital deaths. The procedural time was 67300 (124±62) minutes. Fluoroscopic time was 1750 (23.6±12.1) minutes. The hospital stay was 517 (8.3±3.2) days. Complications included recurrent hemolysis, residual regurgitation, acute renal insufficiency, and anemia. Twenty-seven (77.1) patients improved by 1 New York Heart Association functional class at the 1-year follow-up. Conclusions. Transcatheter mitral PVL closure requires complex catheter techniques. However, this minimally invasive treatment could provide reliable outcomes and shorter hospital stays in selected patients. This trial is registered with NCT02917980.
Background: Severe pulmonary regurgitation (PR) often occurs following a transannular patch repair of tetralogy of Fallot, resulting in an enlarged native right ventricular outflow tract (nRVOT) with varying shapes. Methods: We conducted a single-center study with eight patients having severe PR and enlarged nRVOT (diameters ≥ 29 mm). Transcatheter pulmonary valve replacement (TPVR) was performed using the self-expanding PT-Valve. Preoperative evaluation included echocardiography, computed tomography, and magnetic resonance imaging. A 3D-printed model of the nRVOT was used for preoperative assessment. Follow-up data were collected in 1-year follow-up. Results: PT-Valve was successfully implanted in all patients, resulting in immediate improvement of severe PR. Pulmonary artery diastolic pressure increased significantly (p < 0.001). No deaths or coronary compression occurred during the procedure. Over a 1-year follow-up, no stent displacement or fracture occurred. Only two patients had trace paravalvular leaks. Magnetic resonance imaging revealed a reversal of right ventricular remodeling, with a significant reduction in right ventricular end-diastolic volume index (p < 0.001) and improved right ventricular ejection fraction (p < 0.001). All patients achieved primary endpoints. Conclusion: 3D printing-guided PT-Valve implantation in enlarged nRVOT for severe PR is safe and effective, expanding TPVR indications and offering potential treatment for a broader patient population.
Background: Transcatheter mitral valve-in-ring replacement (TMViR) is an emerging alternative for patients with recurrent mitral regurgitation (MR) after a prior failed annuloplasty ring. However, intraoperative common issues and complications remain to be addressed. Case summary: We describe the case of a 67-year-old male patient who underwent surgical mitral concomitant tricuspid annuloplasty repair 7 years ago who developed recurrent severe MR (New York Heart Association functional class IV). To avoid a high-risk surgical reoperation, we chose to perform a TMViR using an innovative dedicated device—the Mi-thos system—via a transapical approach. A patient-specific, 3-dimensional printed model was used to guide the procedure to avoid potential challenges. The procedure was performed successfully, and the patient exhibited symptomatic improvement. Conclusions: This case report highlights the first use of the innovative Mi-thos system in a TMViR procedure. The findings demonstrate the feasibility and safety of utilizing the Mi-thos system, guided by 3-dimensional printing technology, for patients who have experienced recurrent mitral regurgitation MR following a failed annuloplasty ring.