Shun Tao

Shun Tao


Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 July 2024 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
STShun Tao
Shun Tao
XZxinyi zhu
xinyi zhu
SXShaobo Xu
Shaobo Xu
YXYonghai Xu
Yonghai Xu
Power systems are entering the era of high proportions of new energy and power electronic equipment. The interaction between grid background harmonics and grid-connected inverters (GCIs) leads to frequency coupling effect, which results in additional frequency components injecting into the power networks. However, there is limited research on the modeling of harmonic sources based on the frequency coupling effects. Hence, this article, first, analyzes the harmonic response and emission mechanisms of frequency coupling effect caused by dq -axis asymmetric control of GCIs. Then, the transmission process of harmonic components in sampling delay progress, outer loop, inner loop, phase-locked loop, signal modulation module, and filter of the inverter is deduced. Voltage-controlled coupled harmonic current source models are established considering the frequency coupling effect, suitable for harmonic/interharmonic power flow studies of public supply networks. The proposed models are verified by time-domain simulations under different single harmonic and by hardware-in-the-loop simulations under multiple harmonics. Finally, the impacts of the outer loop, inner loop, phase-locked loop and output power, and the characteristics of harmonic admittance are analyzed.

17 June 2025 in International Journal of Electrical Power & Energy Systems
Verified
Journal Article
Open access
SXShaobo Xu
Shaobo Xu
STShun Tao
Shun Tao
YXYonghai Xu
Yonghai Xu

23 March 2023 in International Journal of Electrical Power & Energy Systems
Verified
Journal Article
Closed access
STShun Tao
Shun Tao
JSJunyan Shen
Junyan Shen
YSYidan Song
Yidan Song
SGShangshu Guan
Shangshu Guan

18 January 2024 in Energies
Verified
Journal Article
Open access
PDF file
HZHuaying Zhang
Huaying Zhang
YWYingxin Wang
Yingxin Wang
XZxinyi zhu
xinyi zhu
YXYonghai Xu
Yonghai Xu
STShun Tao
Shun Tao
With the complication of the power system, features of the resonance interaction behave diversely and pose a threat to the effectiveness of the resonance suppression strategies. Existing resonance suppression strategies are usually designed for specific scenarios which are in close correlation with the impedance frequency-amplitude distribution, and their adaptability under different scenarios is hard to evaluate. In this paper, the resonance suppression domain of a DC distribution network is derived based on the node impedance variation before/after the resonance is suppressed. The derived criterion takes the admittance change of the resonance suppression strategies as variables, and the conservative/ideal suppression domain criteria are defined. On this basis, a method for evaluating the effectiveness of resonance suppression strategies is proposed, which simplifies the evaluation process and avoids a complicated matrix inverse process to each resonance suppression strategy during the system impedance calculation. Furthermore, a DC active damper control strategy based on the resonance suppression strategy evaluation is proposed, and the proposed strategy could suppress resonances under different scenarios by a targeted design of the reshaping admittance parameters. Time domain simulations with a 5-node distribution network are carried out to verify the proposed method.

5 March 2023 in Electronics
Verified
Journal Article
Open access
PDF file
LCLin Chen
Lin Chen
YXYonghai Xu
Yonghai Xu
STShun Tao
Shun Tao
TWTianze Wang
Tianze Wang
SSShuguang Sun
Shuguang Sun
The Norton equivalent model based on the transfer function and the frequency domain analysis method for inverter resonance analysis lacks a comprehensive analysis of the resonant characteristics, and more information about the resonant key components and the degree of participation cannot be obtained. In this paper, a decomposed conductance model is proposed to characterize the resonance characteristics of the multi-inverter grid-connected system and the effect of the equivalent control link of the inverter on the resonance in more detail by combining the modal analysis method and the sensitivity analysis method. Firstly, based on αβ coordinates, the conductance division is carried out for the dual-loop inverter control link with the voltage external loop and current internal loop using capacitor-current feedback damping, and the inverter model based on the decomposition conductance is derived. The mathematical model of the multi-inverter grid-connected system is then established. Secondly, the resonance characteristics of the system are analyzed by combining the modal and frequency domain analysis methods when the number of inverters, inverter parameters, and grid-side impedance are changed. Thirdly, the degree of involvement of the system components, especially the equivalent control link of the inverter in resonance conditions, is determined in combination with the proposed model and the sensitivity analysis method, which is the basis for proposing an effective suppression strategy. Finally, a simulation model is built to verify the proposed method and the analysis results.

1 January 2012
Verified
Conference Paper
Closed access
WSWang Shuo
Wang Shuo
XXXiao Xiangning
Xiao Xiangning
XYXu Yonghai
Xu Yonghai
ZJZheng Jianhui
Zheng Jianhui
STShun Tao
Shun Tao
LYLin Yan
Lin Yan