21 March 2020 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
BCBram Carlier
Bram Carlier
SHSophie Heymans
Sophie Heymans
SNSjoerd Nooijens
Sjoerd Nooijens
YTYosra Toumia
Yosra Toumia
MIMarcus Ingram
Marcus Ingram
ESEdmond Sterpin
Edmond Sterpin
Technologies enabling in vivo range verification during proton therapy are actively sought as a means to reduce the clinical safety margins currently adopted to avoid tumor underdosage. In this contribution, we applied the semi-empirical theory of radiation-induced vaporization of superheated liquids to coated nanodroplets. Nanodroplets are injectable phase-change contrast agents that can vaporize into highly echogenic microbubbles to provide contrast in ultrasound images. We exposed nanodroplet dispersions in aqueous phantoms to monoenergetic proton beams of varying energies and doses. Ultrasound imaging of the phantoms revealed that radiation-induced droplet vaporization occurred in regions proximal to the proton Bragg peak. A statistically significant increase in contrast was observed in irradiated regions for doses as low as 2 Gy and found to be proportional to the proton fluence. The absence of enhanced response in the vicinity of the Bragg peak, combined with theoretical considerations, suggest that droplet vaporization is induced by high linear energy transfer (LET) recoil ions produced by nuclear reactions with incoming protons. Vaporization profiles were compared to non-elastic cross sections and LET characteristics of oxygen recoils. Shifts between the ultrasound image contrast drop and the expected proton range showed a sub-millimeter reproducibility. These early findings confirm the potential of superheated nanodroplets as a novel tool for proton range verification.

1 December 2021 in International Journal of Nanomedicine
Verified
Journal Article
Open access
PDF file
HRHendrik Reynders
Hendrik Reynders
IZIndra Van Zundert
Indra Van Zundert
RSRui Silva
Rui Silva
BCBram Carlier
Bram Carlier
Olivier DeschaumeOlivier Deschaume
Olivier Deschaume
AZAna Zamora
Ana Zamora
Introduction: The inherent fluorescence properties of iron oxide nanoparticles (IONPs) were characterized, and their applicability for multiphoton imaging in cells was tested in combination with their magnetic resonance imaging (MRI) capabilities. Methods: Superparamagnetic iron oxide nanoparticles were synthesized and subsequently coated with polyethylene glycol to make them water-dispersible. Further characterization of the particles was performed using Fourier transform infrared spectroscopy (FT-IR), X-ray diffraction (XRD), dynamic light scattering (DLS), superconducting quantum interference device (SQUID) and magnetic resonance relaxivity measurements. MRI and fluorescence properties of bare IONPs were first studied in solution and subsequently in A549-labeled cells. Results: The particles, with a core size of 11.3 ± 4.5 nm, showed a good negative MRI contrast in tissue-mimicking phantoms. In vitro studies in mammalian A549 cells demonstrate that these IONPs are biocompatible and can also produce significant T2/T2* contrast enhancement in IONPs-labeled cells. Furthermore, excitation-wavelength dependent photoluminescence was observed under one- and two-photon excitation. Discussion: The obtained results indicated that IONPs could be used for fluorescence label-free bioimaging at multiple wavelengths, which was proven by multiphoton imaging of IONPs internalization in A549 cancer cells.

10 October 2024 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
BCBram Carlier
Bram Carlier
SHSophie Heymans
Sophie Heymans
GLGonzalo Collado Lara
Gonzalo Collado Lara
LMLuigi Musetta
Luigi Musetta
MIMarcus Ingram
Marcus Ingram
UHUwe Himmelreich
Uwe Himmelreich
Objective. In proton therapy, range uncertainties prevent optimal benefit from the superior depth-dose characteristics of proton beams over conventional photon-based radiotherapy. To reduce these uncertainties we recently proposed the use of phase-change ultrasound contrast agents as an affordable and effective range verification tool. In particular, superheated nanodroplets can convert into echogenic microbubbles upon proton irradiation, whereby the resulting ultrasound contrast relates to the proton range with high reproducibility. Here, we provide a first in vivo proof-of-concept of this technology. Approach. First, the in vitro biocompatibility of radiation-sensitive poly(vinyl alcohol) perfluorobutane nanodroplets was investigated using several colorimetric assays. Then, in vivo ultrasound contrast was characterized using acoustic droplet vaporization (ADV) and later using proton beam irradiations at varying energies (49.7 MeV and 62 MeV) in healthy Sprague Dawley rats. A preliminary evaluation of the in vivo biocompatibility was performed using ADV and a combination of physiology monitoring and histology. Main results. Nanodroplets were non-toxic over a wide concentration range (<1 mM). In healthy rats, intravenously injected nanodroplets primarily accumulated in the organs of the reticuloendothelial system, where the lifetime of the generated ultrasound contrast (<30 min) was compatible with a typical radiotherapy fraction (<5 min). Spontaneous droplet vaporization did not result in significant background signals. Online ultrasound imaging of the liver of droplet-injected rats demonstrated an energy-dependent proton response, which can be tuned by varying the nanodroplet concentration. However, caution is warranted when deciding on the exact nanodroplet dose regimen as a mild physiological response (drop in cardiac rate, granuloma formation) was observed after ADV. Significance. These findings underline the potential of phase-change ultrasound contrast agents for in vivo proton range verification and provide the next step towards eventual clinical applications.

27 May 2022 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
BHBrent van der Heyden
Brent van der Heyden
SHSophie Heymans
Sophie Heymans
BCBram Carlier
Bram Carlier
GLGonzalo Collado Lara
Gonzalo Collado Lara
ESEdmond Sterpin
Edmond Sterpin
JDJan D'hooge
Jan D'hooge
Objective. External beam radiotherapy is aimed to precisely deliver a high radiation dose to malignancies, while optimally sparing surrounding healthy tissues. With the advent of increasingly complex treatment plans, the delivery should preferably be verified by quality assurance methods. Recently, online ultrasound imaging of vaporized radiosensitive nanodroplets was proposed as a promising tool for in vivo dosimetry in radiotherapy. Previously, the detection of sparse vaporization events was achieved by applying differential ultrasound (US) imaging followed by intensity thresholding using subjective parameter tuning, which is sensitive to image artifacts. Approach . A generalized deep learning solution (i.e. BubbleNet) is proposed to localize vaporized nanodroplets on differential US frames, while overcoming the aforementioned limitation. A 5-fold cross-validation was performed on a diversely composed 5747-frame training/validation dataset by manual segmentation. BubbleNet was then applied on a test dataset of 1536 differential US frames to evaluate dosimetric features. The intra-observer variability was determined by scoring the Dice similarity coefficient (DSC) on 150 frames segmented twice. Additionally, the BubbleNet generalization capability was tested on an external test dataset of 432 frames acquired by a phased array transducer at a much lower ultrasound frequency and reconstructed with unconventional pixel dimensions with respect to the training dataset. Main results. The median DSC in the 5-fold cross validation was equal to ∼0.88, which was in line with the intra-observer variability (=0.86). Next, BubbleNet was employed to detect vaporizations in differential US frames obtained during the irradiation of phantoms with a 154 MeV proton beam or a 6 MV photon beam. BubbleNet improved the bubble-count statistics by ∼30% compared to the earlier established intensity-weighted thresholding. The proton range was verified with a −0.8 mm accuracy. Significance. BubbleNet is a flexible tool to localize individual vaporized nanodroplets on experimentally acquired US images, which improves the sensitivity compared to former thresholding-weighted methods.

14 May 2024 in Pharmaceuticals
Verified
Journal Article
Open access
PDF file
BCBram Carlier
Bram Carlier
SHSophie Heymans
Sophie Heymans
SNSjoerd Nooijens
Sjoerd Nooijens
GLGonzalo Collado Lara
Gonzalo Collado Lara
YTYosra Toumia
Yosra Toumia
UHUwe Himmelreich
Uwe Himmelreich
Radiotherapy treatment plans have become highly conformal, posing additional constraints on the accuracy of treatment delivery. Here, we explore the use of radiation-sensitive ultrasound contrast agents (superheated phase-change nanodroplets) as dosimetric radiation sensors. In a series of experiments, we irradiated perfluorobutane nanodroplets dispersed in gel phantoms at various temperatures and assessed the radiation-induced nanodroplet vaporization events using offline or online ultrasound imaging. At 25 °C and 37 °C, the nanodroplet response was only present at higher photon energies (≥10 MV) and limited to <2 vaporization events per cm2 per Gy. A strong response (~2000 vaporizations per cm2 per Gy) was observed at 65 °C, suggesting radiation-induced nucleation of the droplet core at a sufficiently high degree of superheat. These results emphasize the need for alternative nanodroplet formulations, with a more volatile perfluorocarbon core, to enable in vivo photon dosimetry. The current nanodroplet formulation carries potential as an innovative gel dosimeter if an appropriate gel matrix can be found to ensure reproducibility. Eventually, the proposed technology might unlock unprecedented temporal and spatial resolution in image-based dosimetry, thanks to the combination of high-frame-rate ultrasound imaging and the detection of individual vaporization events, thereby addressing some of the burning challenges of new radiotherapy innovations.

6 June 2025 in IEEE Open Journal of Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Open access
SHSophie Heymans
Sophie Heymans
MIMarcus Ingram
Marcus Ingram
BCBram Carlier
Bram Carlier
BVBrecht Vandenborre
Brecht Vandenborre
MFMarc Fournelle
Marc Fournelle
JDJan D'hooge
Jan D'hooge
Superheated nanodroplets (NDs) are proposed for in vivo radiation dose sensing applications, based on their ability to vaporize into echogenic microbubbles when exposed to ionizing radiation. Combined with Ultrasound Localization Microscopy (ULM), the ultrafast detection of radiation-induced ND vaporization produces super-resolved vaporization maps that match the radiation field with sub-millimeter accuracy. However, in the presence of flow, discriminating between microbubbles moving in the field of view and radiation-induced vaporization events is not trivial. As an alternative, sparse acoustic signatures emitted by vaporizing NDs can be super-localized by passive ULM, i.e. P-ULM. In this work, we extend our previous 2D implementation of P-ULM to 3D, using a large aperture matrix array probe. We exposed perfluorobutane NDs to a proton beam and recorded their vaporization signatures during irradiation. The events were extracted from the radiofrequency channel data using a spatiotemporal filtering approach and super-localized by fitting the time differences of arrival between channels to a one-way time of flight model. The vaporization maps were overlaid on the proton beam distribution and estimated the proton range and beam dispersion within 0.98 ± 0.04 mm and 0.03 ± 0.02 mm of the reference range measurement (depth-dose distribution in water measured with a diode), respectively. These results pave the way for volumetric dose mapping using radiosensitive nanodroplets and passive imaging.