Objective. Transcranial alternating current stimulation (tACS) enables non-invasive modulation of brain activity, holding promise for clinical and research applications. Yet, it remains unclear how the stimulation frequency differentially impacts various neuron types. Here, we aimed to quantify the frequency-dependent behavior of key neocortical cell types. Approach. We used both detailed (anatomical multicompartments) and simplified (three compartments) single-cell modeling approaches based on the Hodgkin–Huxley formalism to study neocortical excitatory and inhibitory cells under various tACS intensities and frequencies within the 5–50 Hz range at rest and during basal 10 Hz activity. Main results. L5 pyramidal cells (PCs) exhibited the highest polarizability at direct current, ranging from 0.21 to 0.25 mm and decaying exponentially with frequency. Inhibitory neurons displayed membrane resonance in the 5–15 Hz range with lower polarizability, although bipolar cells had higher polarizability. Layer 5 PC demonstrated the highest entrainment close to 10 Hz, which decayed with frequency. In contrast, inhibitory neurons entrainment increased with frequency, reaching levels akin to PC. Results from simplified models could replicate phase preferences, while amplitudes tended to follow opposite trends in PC. Significance. tACS-induced membrane polarization is frequency-dependent, revealing observable resonance behavior. Whilst optimal phase entrainment of sustained activity is achieved in PC when tACS frequency matches endogenous activity, inhibitory neurons tend to be entrained at higher frequencies. Consequently, our results highlight the potential for precise, cell-specific targeting for tACS.
Objective. Stereotactic-electroencephalography (SEEG) and scalp EEG recordings can be modeled using mesoscale neural mass population models (NMMs). However, the relationship between those mathematical models and the physics of the measurements is unclear. In addition, it is challenging to represent SEEG data by combining NMMs and volume conductor models due to the intermediate spatial scale represented by these measurements. Approach. We provide a framework combining the multi-compartmental modeling formalism and a detailed geometrical model to simulate the transmembrane currents that appear in layer 3, 5 and 6 pyramidal cells due to a synaptic input. With this approach, it is possible to realistically simulate the current source density (CSD) depth profile inside a cortical patch due to inputs localized into a single cortical layer and the induced voltage measured by two SEEG contacts using a volume conductor model. Based on this approach, we built a framework to connect the activity of a NMM with a volume conductor model and we simulated an example of SEEG signal as a proof of concept. Main results. CSD depends strongly on the distribution of the synaptic inputs onto the different cortical layers and the equivalent current dipole strengths display substantial differences (of up to a factor of four in magnitude in our example). Thus, the inputs coming from different neural populations do not contribute equally to the electrophysiological recordings. A direct consequence of this is that the raw output of NMMs is not a good proxy for electrical recordings. We also show that the simplest CSD model that can accurately reproduce SEEG measurements can be constructed from discrete monopolar sources (one per cortical layer). Significance. Our results highlight the importance of including a physical model in NMMs to represent measurements. We provide a framework connecting microscale neuron models with the neural mass formalism and with physical models of the measurement process that can improve the accuracy of predicted electrophysiological recordings.
Objective. Fast ripples (FRs) have received considerable attention in the last decade since they represent an electrophysiological biomarker of the epileptogenic zone (EZ). However, the real dynamics underlying the occurrence, amplitude, and time-frequency content of FRs generation during epileptogenesis are still not well understood. This work aims at characterizing and explaining the evolution of these features. Approach. Intracortical electroencephalographic signals recorded in a kainate mouse model of temporal lobe epilepsy were processed in order to compute specific FR features. Then realistic physiologically based computational modeling was employed to explore the different elements that can explain the mechanisms of epileptogenesis and simulate the recorded FR in the early and late latent period. Main results. Results indicated that continuous changes of FR features are mainly portrayed by the epileptic (pathological) tissue size and synaptic properties. Furthermore, the microelectrodes characteristics were found to dramatically affect the observability and spectral/temporal content of FRs. Consequently, FRs evolution seems to mirror the continuous pathophysiological mechanism changes that occur during epileptogenesis as long as the microelectrode properties are taken into account. Significance. Our study suggests that FRs can account for the pathophysiological changes which might explain the EZ generation and evolution and can contribute in the treatment plan of pharmaco-resistant epilepsies.
30 March 2021 in Annals of Clinical and Translational Neurology
Objective: Studies of motor outcome after Neonatal Arterial Ischemic Stroke (NAIS) often rely on lesion mapping using MRI. However, clinical measurements indicate that motor deficit can be different than what would solely be anticipated by the lesion extent and location. Because this may be explained by the cortical disconnections between motor areas due to necrosis following the stroke, the investigation of the motor network can help in the understanding of visual inspection and outcome discrepancy. In this study, we propose to examine the structural connectivity between motor areas in NAIS patients compared to healthy controls in order to define the cortical and subcortical connections that can reflect the motor outcome.Methods: Thirty healthy controls and 32 NAIS patients with and without Cerebral Palsy (CP) underwent MRI acquisition and manual assessment. The connectome of all participants was obtained from T1‐weighted and diffusion‐weighted imaging.Results: Significant disconnections in the lesioned and contra‐lesioned hemispheres of patients were found. Furthermore, significant correlations were detected between the structural connectivity metric of specific motor areas and manuality assessed by the Box and Block Test (BBT) scores in patients.Interpretation: Using the connectivity measures of these links, the BBT score can be estimated using a multiple linear regression model. In addition, the presence or not of CP can also be predicted using the KNN classification algorithm. According to our results, the structural connectome can be an asset in the estimation of gross manual dexterity and can help uncover structural changes between brain regions related to NAIS.
1 March 2023 in IEEE Transactions on Biomedical Engineering
Objective : Microelectrodes allow for the recording of neural activities with a high spatial resolution. However, their small sizes result in high impedance causing high thermal noise and poor signal-to-noise ratio. In drug-resistant epilepsy, the accurate detection of Fast Ripples (FRs; 250-600 Hz) can help in the identification of epileptogenic networks and Seizure Onset Zone (SOZ). Consequently, good-quality recordings are instrumental to improve surgical outcome. In this work, we propose a novel model-based approach for the design of microelectrodes optimized for FRs recording. Methods : A 3D microscale computational model was developed to simulate FRs generated in the hippocampus (CA1 subfield). It was coupled with a model of the Electrode-Tissue Interface (ETI) that accounts for the biophysical properties of the intracortical microelectrode. This hybrid model was used to analyze the microelectrode geometrical (diameter, position, and direction) and physical (materials, coating) characteristics and their impact on recorded FRs. For model validation, experimental signals (local field potentials, LFPs) were recorded from CA1 using different electrode materials: stainless steel (SS), gold (Au) and Au coated with poly(3,4-ethylene dioxythiophene) /Poly(styrene sulfonate) (Au:PEDOT/PSS). Results : results indicated that a radius between 65 and 120 $\mu m$ for a wire microelectrode is the most optimal for recording FRs. In addition, in silico and in vivo quantified results showed a possible improvement in FRs observability using PEDOT/PSS coated microelectrodes. Conclusion : the optimization of the design of microelectrodes for FRs recording can improve the observability and detectability of FRs which are a recognized marker of epileptogenicity. Significance : This model-based approach can assist in the design of hybrid electrodes (micro, macro) that can be used in the presurgical evaluation of epileptic patients with drug-resistant epilepsy.