The International Maritime Organization are introducing more and more stringent requirements concerning increasing ships’ energy efficiency. They are becoming a huge challenge for design engineers. This article proposes a method to increase the energy efficiency of mechatronic drive systems in ship systems via the use of highly efficient electric permanent magnet synchronous motors (PMSMs). An innovative control strategy is suggested. It is based on the modification of the classic PMSM control and ensuring energy optimization through a reduction in reactive power in the Active Converter–PMSM system. Analytical and simulation studies using the Matlab–Simulink program are presented. They confirm the possibility of reducing reactive power in a PMSM drive system. A verification of the results of analytical and simulation examinations was conducted at a laboratory station with the use of the Speedgoat module operating in the Rapid Control Prototyping mode. Both the simulation and experimental research results indicate the effectiveness of the proposed PMSM control method. This method has good prospects for application in energy-saving marine drive systems.
In marine systems, autonomous power generation unit sets play an important (main) function, and the Automatic Voltage Regulator (AVR) is a part of the excitation system of a synchronous generator that is difficult to test, repair, and adjust by the Electro Technical Officer (ETO) and marine automation services. Typically, testing of the AVR on ships is carried out on installed AVRs in an operating generator, which creates significant challenges. Under operating conditions, achieving various generator operating states is practically impossible. In this article, the authors present a solution that replaces traditional AVR testing by using Hardware-in-the-Loop (HiL) technology, allowing for full diagnostics. Testing the AVR in a loop allowed verification of its performance without a real generator, which is simulated in real time. The possibility of diagnosing the AVR under different standalone generator conditions (dynamic load changes and load character changes) was presented. Test scenarios were carried out in real time on a sample AVR from LXCOS V1.4.5.2 and the HiL simulator from Speedgoat. The solution proposed by the authors in the article enables effective diagnostics of the AVR with high practicality and low costs.
Urban digitalization requires site-specific evidence to determine where intelligent sensing, edge processing, warning actuation and energy management functions are justified. This repeated cross-sectional field study quantified changes in smartphone-related behaviour and electrified micromobility at an unsignalized roundabout in Kielce, Poland, and translated them into technical requirements and an energy budget for a privacy-preserving, energy-aware crossing infrastructure. Two observers recorded 27,487 crossing-area users in 1728 arm-specific five-minute intervals during 18 standardized two-hour sessions in 2023–2025. Any phone use increased from 41.87% to 48.63% (difference 6.76 percentage points, 95% CI 5.31–8.20; Cohen’s h = 0.14), and a combined electric micromobility exposure indicator increased from 11.84% to 22.39% (h = 0.28), while bicycle prevalence remained near 8%. The phone-use trend was robust to the clustering of observations: session-clustered logistic regression, a random-intercept model and an exact stratified permutation test using the 18 sessions as independent units (p < 0.001) gave consistent results, and a composition analysis showed that the trend was not explained by the growing share of micromobility users. The effects are small in standardized terms but correspond to approximately 120 additional phone-engaged users per hour at peak volumes. The framework specifies homography-based trajectory prediction, time-to-collision conflict detection, a logistic risk score with data-driven threshold selection, k-anonymous aggregate data release and a staged validation plan with key performance indicators. A field-calibrated, state-based energy budget estimated 0.63–0.73 kWh/day for event-based operation of a four-approach edge node, 28–42% less than presence-activated and 60–65% less than continuously active operation. Transport-energy savings cannot be inferred because trip distances and displaced modes were not observed.
Parallel operation of synchronous generators in a shipboard power system requires properly coordinated Automatic Voltage Regulators (AVRs). AVR mismatch can cause unequal reactive power sharing and increased generator currents. In operational and service practice, the possibilities for safe and repeatable diagnosis of AVR settings under parallel-operation conditions are limited. Conventional workshop tests do not reproduce the complete coupling between the regulators, common-bus voltage, stator currents, and reactive power flow. This paper presents the development and experimental assessment of a Hardware-in-the-Loop platform for testing two physical digital AVRs coupled to real-time models of two synchronous generators, prime movers, a common main switchboard (MSB), and a load. The platform uses a common voltage interface and inverter-based stator-current reproduction interfaces. The current-reproduction interface was functionally validated. A reference operating test and tests of the effects of differences in proportional gain, integral time, voltage reference, and voltage droop settings were performed. Matched AVR settings provided stable operation following load changes. Mismatched voltage references and voltage droop settings caused persistent unequal reactive power sharing. Zero voltage droop caused oscillatory reactive power exchange and increased generator currents. The platform enables safe and repeatable assessment of physical AVRs during parallel generator operation without the use of high-power synchronous generators.