PV Premalatha

Dr. PV Premalatha

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2018 in Computers and Geotechnics
Verified
Journal Article
Closed access
SSS. Sivakumar
S. Sivakumar
NBN. Almas Begum
N. Almas Begum
PPPV Premalatha
PV Premalatha

1 December 2015 in Maritime Engineering
Verified
Journal Article
Closed access
PPPV Premalatha
PV Premalatha
KMKasinathan Muthukumaran
Kasinathan Muthukumaran
PJPerumalsami Jayabalan
Perumalsami Jayabalan
This paper deals with an experimental investigation on laterally loaded piles of a berthing structure. A prototype berthing structure constructed at Chennai Port in India is simulated in a 1∶40 laboratory scale model. The model consists of a row of five piles connected at the top by a wooden beam for rigidity and to transfer the load laterally to the piles. A tie rod is incorporated in this frame to study its effect. A series of seven experiments was conducted with and without the anchoring tie rod, in sloping and horizontal ground under berthing and mooring forces. The experimental results were analysed to assess the effect of the tie rod anchor on the berthing structure. The distribution of load among the piles and the tie rod anchor, the lateral capacity of the pile under various cases and the reduction in deflection and bending moment due to the provision of a tie rod anchor are discussed in this paper. The provision of tie rods is found to be effective for open-type berthing structures.

6 October 2017 in Journal of Testing and Evaluation
Verified
Journal Article
Closed access
KKK. Senthil Kumar
K. Senthil Kumar
PPPV Premalatha
PV Premalatha
KBK. Baskar
K. Baskar
GPG. Sankaran Pillai
G. Sankaran Pillai
PHP. Shahul Hameed
P. Shahul Hameed
The paper reports the impact of e-waste plastic [high-impact polystyrene (HIPS)] mixing in concrete on its radioactivity profile. The concrete was prepared with HIPS as a partial replacement for coarse aggregate in varying percentages by volume and radioactivity concentrations of 238U, 232Th, and 40K were measured using gamma-ray spectrometer and radon activity by solid state nuclear track detector (SSNTD) technique. Both gamma radiation and radon activity in standard concrete and concrete with HIPS were well within the permissible limit. However, the gamma-radiation level and radon activity decreased with an increase in HIPS content of the concrete. The study concludes that the concrete with HIPS does not pose any radiation hazard and, hence, is suitable as a construction material.

1 November 2016 in Journal of Testing and Evaluation
Verified
Journal Article
Closed access
VPVelumani Periasamy
Velumani Periasamy
SSS. SenthilKumar
S. SenthilKumar
PPPV Premalatha
PV Premalatha
The Industrial Revolution turned a new leaf in the economic growth of India, which is famous for its industries and agriculture. Notably, the textile industry, which is one of the major sectors, has had rapid growth throughout India in general and Tamil Nadu in particular. The government of India has earmarked seven hundred crore rupees in its twelfth five-year plan during 2012–2017 for the development of textiles to increase production at a large scale. For the largest production operations, the necessity arises for the treatment of effluents to be carried out jointly by companies or as individual industries. Apparently, the treatment of textile effluents generates sludge in bulk quantities. This poses a challenge for its disposal. So, attempts were taken to use the sludge as an affordable construction material. Sludge was collected from the effluent treatment plants of the textile industries located in the State Industries Promotion Corporation of Tamil Nadu (SIPCOT), Perundurai, which is popularly known as a commercial hub. To make a brick, materials like hypo sludge, textile sludge, quarry dust, fly ash, and gypsum were added in suitable proportion. The manufacture of bricks was done in accordance with Indian standard practice. Not only observations but also evaluations were made correctly. There was an increase in strength, which satisfied the criteria of durability, as hypo sludge content was increased. All the combinations that were formulated for the production of brick satisfy Bureau of Indian Standards (BIS) requirements.

1 August 2019 in Heliyon
Verified
Journal Article
Open access
SSS. Sivakumar
S. Sivakumar
NBN. Almas Begum
N. Almas Begum
PPPV Premalatha
PV Premalatha
Numerical study is carried out to analyse the behaviour of cut off walls in sandy soil, under constant differential pressure head, by varying its location from upstream end to downstream end. The deformation and bending moment in cut off wall are at their lowest magnitude when the cut off wall is positioned at upstream end. The cut off wall is subjected to second lowest deformation, when it is positioned at downstream end. The maximum deformation occurs, when the cut off wall is positioned at 0.60 times the total width of diversion dam from upstream end. The seepage rate in the diversion dam is highest when the cut off wall is positioned at centre of the diversion dam. The seepage rate in the diversion dam is having direct relation with the maximum displacement and maximum bending moment. The seepage force found to be more predominant than the pressure gradient and active pore pressure variations in deforming the cut off walls of diversion dams.

26 July 2023
Verified
Conference Paper
Open access
PDF file
PPPV Premalatha
PV Premalatha
MGM. Geethanjali
M. Geethanjali
TRT. Rahuraman
T. Rahuraman
SGS. Gurusaran
S. Gurusaran
Traditionally, river sand was utilized as fine aggregate in concrete manufacturing. However, due to the ongoing extraction of natural river sand, its availability has become limited. Construction businesses have begun to explore for alternative sustainable resources to use as fine aggregate. Manufactured sand (M- sand), recycled concrete aggregate, crushed granite, rice husk ash, fly ash, and other materials can cause dumpsite and environmental contamination. These materials are viable substitutes for natural river sand as fine aggregate. Unexpanded perlite is also one such material which can be used as a replacement for fine aggregate. Unexpanded Perlite is a natural material in the form of volcanic glass resulted from cooled lava. This paper presents the utilization of M-Sand with partial replacement of unexpanded perlite as a fine aggregate. In the present research, the effect of unexpanded Perlite with M- sand in concrete is studied to determine the mechanical properties such as compressive strength at 7 days, 14 days and 28 days, split tensile strength at 28days and flexural strength at 28 days. M-Sand is used in the range of 62%, 60%, 58%, 56%, 54%, 52% and 50% with Unexpanded Perlite UP in the percentage of 38%, 40%, 42%, 44%, 46%, 48% and 50% respectively. The Unexpanded Perlite can withstand the 1.5 times of thermal resistivity when compared to the conventional concrete.